NuCodeComp - intro

NuCodeComp

The International Bureau of Weights and Measures (BIPM) has launched the NuCodeComp project — a collaborative platform for digital comparisons in radionuclide metrology.

NuCodeComp is designed to support the validation of algorithms and software used in the analysis of radioactivity measurements. It provides a standardized framework that enables participants to analyze common benchmark datasets, share their results, and compare their performance across the community.

As part of the initiative, a series of benchmarked measurement projects (e.g., BIPM.RI(II)-digP1, BIPM.RI(II)-digP2, ...) are provided. Each project includes:

  • Standardized list-mode data files
  • Accompanying metadata
  • A downloadable results submission form

How to Participate

  1. Download one of the benchmark projects and its associated data files from the list below.
  2. Analyze the data using your own software or algorithms.
  3. Complete the reportingForm.csv with your findings.
  4. Submit the completed form by email to Romain Coulon.

For assistance in the participation process, please contact Romain Coulon.

For assistance with ensuring interoperability with your software’s input format, please contact John Keightley.

NuCodeComp - projects

Benchmarck projects

You'll find below information about BIPM.RI(II)-digP1 and BIPM.RI(II)-digP2.

BIPM.RI(II)-digP1

Files to be downloaded

 acronym

 BIPM.RI(II)-digP1

 status

 Active

 pilot institute

 BIPM

 data provider

 BIPM

 measurement type 

 4pi(TDCR)beta-gamma

 data type

 Experimental

 service category

 https://si-digital-framework.org/kcdb-sc/RI/RAD-1.3.1         

 measurand

 Activity

 radionuclide

 Co-60

 opening date

 2026-01-01 00:00:00 (UTC)

 closing date

 2026-12-15 00:00:00 (UTC)

 reference date

 2021-02-22 12:00:00 (UTC)

 half life

 1.6634E+11 s

 data size

 1.1 GB

 notes  

 - the background has to be subtracted

 - the specified half life has to be used

BIPM.RI(II)-digP2

Files to be downloaded

 acronym

 BIPM.RI(II)-digP2

 status

 Active

 pilot institute

 BIPM

 data provider

 BIPM

 measurement type 

 TDCR

 data type

 Experimental

 service category

 https://si-digital-framework.org/kcdb-sc/RI/RAD-1.3.1 

 measurand

 Activity

 radionuclide

 Pm-147

 opening date

 2026-01-01 00:00:00 (UTC)

 closing date

 reference date

 2024-12-16 12:00:00 (UTC)

 half life 

 8.28E+07 s

 data size

 3.6 GB

 notes

 - no background substration to account

 - contain efficiency changing using grey filters