CIPM MRA COMPARISON REPORTS
SUPPLEMENTARY COMPARISON
EURAMET.M.T-S6
Abstract
This report describes the supplementary comparison EURAMET.M.T-S6 for torque value from 10 N·m to 500 N·m between PTB (Germany) and LNE (France) in both clockwise and anticlockwise direction. In this comparison exercise, five torque transducers were used as transfer standards. The results of the transducers at each torque step, expressed as relative deviations between the measurement results of LNE and PTB, were combined using the generalized weighted mean. Two evaluations were considered: the first with the relative deviations supposed uncorrelated and the second with the relative deviations supposed correlated. Both evaluations supports the uncertainty claims of LNE for this comparison.
Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).