CIPM MRA COMPARISON REPORTS

BIPM.RI(I)-K7 (ENEA-INMRI 2025)

Measurement of air kerma for mammography beams
A. Villevalde , C. Kessler , F. Curciarello , G. Cappadozzi , A. Ciccotelli , C. Silvestri , M. Pinto
Published on 26/08/2026 - © 2026 A. Villevalde et al
Citation A. Villevalde et al 2026 CIPM MRA Comparison reports 06010

Abstract

A new key comparison has been made between the air-kerma standards of the ENEA-INMRI, Italy, and the BIPM in mammography x-ray beams. The results show the standards to agree at the level of the expanded uncertainty of the comparison of 7.8 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.