MEASURAND: Luminous flux

Degrees of equivalence relative to the CCPR-K4 key comparison reference value, Di and Ui, expressed in relative terms

Red diamonds: participants in CCPR.PR-K4
Blue triangles: participants in EURAMET.PR-K4
Green circles: participants in SIM.PR-K4
Orange squares: participants in COOMET.PR-K4.1
Purple triangles: participants in APMP.PR-K4
Sky blue diamonds: participants in EURAMET.PR-K4.2

Brown diamond: participant in EURAMET.PR-K4.3
 

Comparison
Comparison close
Results

CCPR-K4, EURAMET.PR-K4, SIM.PR-K4, COOMET.PR-K4.1,
APMP.PR-K4, EURAMET.PR-K4.2 and EURAMET.PR-K4.3

MEASURAND: Luminous flux

Degrees of equivalence relative to the CCPR-K4 key comparison reference value, Di and Ui, expressed in relative terms

Dark blue: participants in CCPR-K4
Blue: participants in EURAMET.PR-K4
Green: participants in SIM.PR-K4
Orange: participants in COOMET.PR-K4.1
Purple: participants in APMP.PR-K4
Sky blue: participants in EURAMET.PR-K4.2

Brown: participant in EURAMET.PR-K4.3
 

The cutoff uncertainty (0.30 %) was applied to the measurements of LNE-INM/Cnam, NMIA, NIM, NPL and PTB in the calculation of xR.

Measurements from INTI and the BIPM were excluded from the calculation of xR.

Acronyms of participants in CCPR-K4 (1997 - 1998) were updated in June 2015.

Results are presented under A4 printable format in Summary Results (PDF file).

 

EURAMET.PR-K4
Metrology area, Sub-field Photometry and Radiometry, Photometry
Description Luminous flux
Time of measurements 2009 - 2011
Status Approved for equivalence
Final Reports of the comparisons
References

EURAMET.PR-K4 Technical Protocol

Measurand Luminous flux
Transfer device Lamps
Comparison type Key Comparison
Consultative Committee CCPR (Consultative Committee for Photometry and Radiometry)
Conducted by EURAMET (European Association of National Metrology Institutes)
RMO Internal Identifier EUROMET Project No 569
Comments

Results published on 5 June 2015

Luminous flux of lamps

EURAMET.PR-K4, SIM.PR-K4, COOMET.PR-K4.1, APMP.PR-K4, EURAMET.PR-K4.2 and EURAMET.PR-K4.3 results are linked to those of CCPR-K4

Pilot institute PTB
Physikalisch-Technische Bundesanstalt
Germany
Contact person M. Lindemann

+49 531 592 4125
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

BEV

Bundesamt für Eich- und Vermessungswesen, Austria, EURAMET

BIM

Bulgarian Institute of Metrology, Bulgaria, EURAMET

CMI

Czech Metrology Institute, Czechia, EURAMET

DMDM

Directorate of Measures and Precious Metals, Serbia, EURAMET

GUM

Glowny Urzad Miar, Central Office of Measures, Poland, EURAMET

INM

National Institute of Metrology, Romania, EURAMET

INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

LNE-LCM/Cnam

Conservatoire National des Arts et Métiers/Laboratoire Commun de Métrologie, France, EURAMET

MIKES

VTT Technical Research Centre of Finland Ltd, Centre for Metrology/Mittatekniikan keskus, Finland, EURAMET

VSL

VSL, Netherlands, EURAMET

Comparison
Comparison close
Results

CCPR-K4, EURAMET.PR-K4, SIM.PR-K4, COOMET.PR-K4.1,
APMP.PR-K4, EURAMET.PR-K4.2 and EURAMET.PR-K4.3

MEASURAND : Luminous flux

  • Key comparison CCPR-K4

The key comparison reference value, xR, is calculated as the weighted average of the invidual results xi, weighted by the inverse square of the individual standard uncertainties, ui, with the application of a minimum cutoff of 0.30%.
INTI and the BIPM are excluded from the calculation of xR.
The standard uncertainty of xR is uR = 0.1%. It is negligible compared to the ui values.

The degree of equivalence of each laboratory with respect to the reference value is given by a pair of terms: Di = (xi - xR) / xR and Ui, its expanded uncertainty (k = 2), both expressed in relative units. Ui = 2ui.
When required, the degree of equivalence between two laboratories is given by a pair of terms: Dij = (xi - xj) / xR and Uij, its expanded uncertainty (k = 2), both expressed in relative units. Uij = 2(ui2 + uj2)1/2.
  • Linking EURAMET.PR-K4 to CCPR-K4

Beside the pilot laboratory, PTB, INRIM and LNE-INM/Cnam acted as linking laboratories for EURAMET.PR-K4. The luminous flux maintained at the linking laboratories was used to evaluate the EURAMET reference value as a weighted luminous flux average.

By definition, the CCPR-K4 key comparison reference value and the EURAMET.PR-K4 reference value have identical values (see Section 4.2 of the EURAMET.PR-K4 Final Report, especially Table 4 and Figure 4), but the expanded uncertainty associated with the EURAMET reference value is about triply the expanded uncertainty associated with the CCPR-K4 key comparison reference value.

The realized or preserved luminous flux values of the EURAMET participants were compared with the EURAMET reference value in a star-type comparison at the pilot with batches of three to six lamps of various types.
The degrees of equivalence with respect to the EURAMET reference value were evaluated and then directly transferred to the CCPR-K4 key comparison reference value.
  • Linking SIM.PR-K4 to CCPR-K4

NRC and NIST provide the link between key comparisons CCPR-K4 and SIM.PR-K4 and, the linkage process is described in Section 9.2 of the SIM.PR-K4 Final Report.

The degree of equivalence of the participant in SIM.PR-K4 with respect to the key comparison reference value is given by a pair of terms both dimensionless:
Di and Ui, its expanded uncertainty (k = 2), computed as explained in Section 9.2 of the Final Report.

  • Linking COOMET.PR-K4.1 to CCPR-K4

VNIIOFI provides the link between key comparisons CCPR-K4 and COOMET.PR-K4.1, and the linkage process is described in Section 5 of the COOMET.PR-K4.1 Final Report.

The degree of equivalence of NSC "Institute of Metrology" participant in COOMET.PR-K4.1 with respect to the key comparison reference value is given by a pair of terms both dimensionless:
Di and Ui, its expanded uncertainty (k = 2), computed as explained in Section 6 of the Final Report.

  • Linking APMP.PR-K4 to CCPR-K4

NIM, NMISA and NMIJ-AIST provide the link between key comparisons CCPR-K4 and APMP.PR-K4, and the linkage process is described in Section 8 of the APMP.PR-K4 Final Report.

The degree of equivalence of the participants in APMP.PR-K4 with respect to the key comparison reference value is given by a pair of terms both dimensionless:
Di and Ui, its expanded uncertainty (k = 2), computed as explained in Section 8 of the Final Report.

  • Linking EURAMET.PR-K4.2 to CCPR-K4

LNE/INM-Cnam provides the link between key comparisons CCPR-K4 and EURAMET.PR-K4.2, and the linkage process is described in Section 4 of the EURAMET.PR-K4.2 Final Report.

The degree of equivalence of RMC-LIPI, participant in EURAMET.PR-K4.2 with respect to the key comparison reference value is given by a pair of terms both dimensionless:
Di and Ui, its expanded uncertainty (k = 2), computed as explained in Section 8 of the Final Report.

  • Linking EURAMET.PR-K4.3 to CCPR-K4

IO-CSIC provides the link between key comparisons CCPR-K4 and EURAMET.PR-K4.3, and the linkage process is described in Section 5 of the EURAMET.PR-K4.3 Final Report.

The degree of equivalence of UME participant in EURAMET.PR-K4.3 with respect to the key comparison reference value is given by a pair of terms both dimensionless:
Di and Ui, its expanded uncertainty (k = 2), computed as explained in Section 5 of the Final Report.

Comparison
Comparison close
Results

CCPR-K4, EURAMET.PR-K4, SIM.PR-K4, COOMET.PR-K4.1,
APMP.PR-K4, EURAMET.PR-K4.2 and EURAMET.PR-K4.3

MEASURAND: Luminous flux

  • Key comparison CCPR-K4

The individual measurements, xi, of the participating laboratories take the form of ratios which depend on the reference used at the pilot laboratory, the PTB. This is cancelled out by normalization using the key comparison reference value, xR. This procedure leads to normalized individual measurements: xi / xR.

  • Key comparison EURAMET.PR-K4

The participants' measurements are given in Annex B of the EURAMET.PR-K4 Final Report.

  • Key comparison SIM.PR-K4

The ratio of the measurement results of the laboratories participating in SIM.PR-K4 to the measurement results obtained at the pilot laboratory, the CENAM, are given in table 15 of the SIM.PR-K4 Final Report.

  • Key comparison COOMET.PR-K4.1

The measurement results of the laboratories participating in COOMET.PR-K4.1 are given in table 7 of the COOMET.PR-K4.1 Final Report.

  • Key comparison APMP.PR-K4

The measurement results of the participants in APMP.PR-K4 are given in Section 6  of the APMP.PR-K4 Final Report.

  • Key comparison EURAMET.PR-K4.2

The measurement results of the participants in EURAMET.PR-K4.2 are given in Section 4  of the EURAMET.PR-K4.2 Final Report.

  • Key comparison EURAMET.PR-K4.3

The measurement results of the participants in EURAMET.PR-K4.3 are given in Section 3 and 4  of the EURAMET.PR-K4.3 Final Report.