CCM.P-K15 and CCM.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-2 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-2 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 0.3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 9.0E-03 | 3.9E-02 | ||
CENAM | -9.3E-03 | 7.7E-02 | ||
NIST | -2.0E-04 | 2.0E-02 | ||
INRIM | -4.0E-04 | 2.9E-02 | ||
PTB | -6.5E-03 | 2.7E-02 | ||
METAS | 2.0E-03 | 1.7E-02 | ||
NIM | 9.0E-04 | 1.5E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 6.5E-03 | 1.7E-02 | ||
CENAM | 5.4E-03 | 2.5E-02 | ||
NIST | -1.9E-03 | 7.0E-03 | ||
INRIM | 6.0E-04 | 1.9E-02 | ||
PTB | -3.3E-03 | 1.3E-02 | ||
METAS | 1.1E-03 | 9.2E-03 | ||
NIM | 1.2E-03 | 7.1E-03 | ||
NIMT | -9.8E-03 | 3.2E-02 | ||
UME | -6.4E-03 | 1.7E-02 | ||
IMT | -4.4E-03 | 1.6E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-4 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 5.8E-03 | 1.1E-02 | ||
KRISS | -1.9E-03 | 2.0E-02 | ||
CENAM | 2.8E-03 | 1.3E-02 | ||
NIST | -4.0E-04 | 3.5E-03 | ||
INRIM | -7.0E-04 | 1.5E-02 | ||
PTB | -3.2E-03 | 1.0E-02 | ||
METAS | -9.0E-04 | 9.7E-03 | ||
NIM | 1.2E-03 | 4.7E-03 | ||
NIMT | -9.0E-03 | 1.9E-02 | ||
UME | -4.1E-03 | 1.5E-02 | ||
IMT | -3.6E-03 | 1.4E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 6.5E-03 | 1.1E-02 | ||
KRISS | -1.2E-03 | 2.0E-02 | ||
CENAM | 2.0E-04 | 1.1E-02 | ||
NIST | -4.0E-04 | 3.9E-03 | ||
INRIM | 0.0E+00 | 1.2E-02 | ||
PTB | -2.9E-03 | 9.9E-03 | ||
METAS | -3.0E-04 | 5.7E-03 | ||
NIM | 1.0E-03 | 3.9E-03 | ||
NIMT | -8.6E-03 | 1.8E-02 | ||
UME | -4.8E-03 | 1.4E-02 | ||
IMT | -2.8E-03 | 1.4E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 6.0E-03 | 1.1E-02 | ||
KRISS | -2.9E-03 | 2.0E-02 | ||
CENAM | 1.0E-04 | 5.4E-03 | ||
NIST | -2.0E-04 | 3.4E-03 | ||
INRIM | -5.0E-04 | 1.0E-02 | ||
PTB | -1.6E-03 | 9.5E-03 | ||
METAS | -5.0E-04 | 5.9E-03 | ||
NIM | 6.0E-04 | 3.6E-03 | ||
NIMT | -7.0E-03 | 1.6E-02 | ||
UME | -4.6E-03 | 1.4E-02 | ||
IMT | -2.5E-03 | 1.3E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-2 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 6.0E-03 | 1.0E-02 | ||
KRISS | -6.2E-03 | 2.1E-02 | ||
CENAM | -4.0E-04 | 4.9E-03 | ||
NIST | -2.0E-04 | 3.5E-03 | ||
INRIM | -4.0E-04 | 1.0E-02 | ||
PTB | -2.0E-03 | 9.8E-03 | ||
METAS | 3.0E-04 | 5.9E-03 | ||
NIM | 1.3E-03 | 3.4E-03 | ||
NIMT | -7.2E-03 | 1.8E-02 | ||
UME | -3.7E-03 | 1.4E-02 | ||
IMT | -1.4E-03 | 1.3E-02 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-2 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 6.5E-03 | 1.1E-02 | ||
KRISS | -1.3E-02 | 2.4E-02 | ||
CENAM | -1.0E-04 | 5.0E-03 | ||
NIST | 6.0E-04 | 3.8E-03 | ||
INRIM | -3.0E-04 | 7.5E-03 | ||
PTB | -2.6E-03 | 6.1E-03 | ||
METAS | 3.0E-04 | 6.1E-03 | ||
NIM | 1.3E-03 | 2.8E-03 | ||
NIMT | -7.5E-03 | 1.3E-02 | ||
UME | -4.1E-03 | 1.0E-02 | ||
IMT | -2.4E-03 | 9.3E-03 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 0.3 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 5.3E-03 | 1.1E-02 | ||
CENAM | -1.1E-03 | 5.0E-03 | ||
NIST | 1.0E-03 | 4.1E-03 | ||
INRIM | -8.0E-04 | 6.7E-03 | ||
PTB | -2.7E-03 | 5.5E-03 | ||
METAS | 9.0E-04 | 4.3E-03 | ||
NIM | 3.0E-04 | 3.1E-03 | ||
NIMT | -6.3E-03 | 1.3E-02 | ||
UME | -4.1E-03 | 9.3E-03 | ||
IMT | -1.7E-03 | 8.8E-03 |
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 Pa
Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in non-dimensional units.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
Pa/Pa |
Pa/Pa |
Pa/Pa |
||
NMIJ | 4.6E-03 | 1.1E-02 | ||
CENAM | 2.0E-04 | 4.1E-03 | ||
NIST | 1.3E-03 | 3.1E-03 | ||
INRIM | -3.2E-03 | 7.5E-03 | ||
PTB | -3.6E-03 | 5.9E-03 | ||
METAS | 1.0E-04 | 3.9E-03 | ||
NIM | 4.0E-04 | 3.0E-03 | ||
NIMT | -5.6E-03 | 1.3E-02 | ||
UME | -4.0E-03 | 9.6E-03 | ||
IMT | -1.7E-03 | 9.1E-03 |
Metrology area, Sub-field | Mass and related quantities, Pressure |
Description | Comparison of absolute pressure in the range 0.1 mPa to 1 Pa |
Time of measurements | 2010 - 2011 |
Status | Approved for equivalence |
Final Reports of the comparisons | |
Measurand | Pressure: 0.1 mPa to 1 Pa |
Transfer device | Two spinning rotor gauges |
Comparison type | Key Comparison |
Consultative Committee | CCM (Consultative Committee for Mass and Related Quantities) |
Conducted by | CCM (Consultative Committee for Mass and Related Quantities) |
Comments | Comparison renamed from CCM.P-K14 to CCM.P-K15 on 28 November 2016 Results published on 19 December 2016 Absolute pressure |
Pilot institute |
METAS
Federal Institute of Metrology Switzerland |
Contact person | C. Wüthrich +41 (0) 31 32 33 423 |
Pilot laboratory | |
---|---|
METAS |
Federal Institute of Metrology, Switzerland, EURAMET |
CENAM |
Centro Nacional de Metrologia, Mexico, SIM |
INRIM |
Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET |
KRISS |
Korea Research Institute of Standards and Science, Korea, Republic of, APMP |
NIST |
National Institute of Standards and Technology, United States, SIM |
NMIJ AIST |
National Metrology Institute of Japan, Japan, APMP |
PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
CCM.P-K15 and CCM.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 x 10-4 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-4 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-4 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-3 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-3 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-2 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-2 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 0.3 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 Pa
CCM.P-K15
The key comparison reference value, xR, is adopted as the nominal value of the pressure. The standard uncertainty of the key comparison reference value, uR, is calculated according to Eq. (40) of the CCM.P-K15 Final Report, at each pressure.
For each pressure, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) / xR, the relative deviation from the reference value, and Ui , its relative expanded uncertainty (k = 2) calculated according to Eq. (41) of the CCM.P-K15 Final Report.
Linking CCM.P-K15.1 to CCM.P-K15
The results of CCM.P-K15.1 were linked to CCM.P-K15 via METAS who participated in both comparisons.
Linking EURAMET.M.P-K15.1 to CCM.P-K15
The results of EURAMET.M.P-K15.1 were linked to CCM.P-K15 via PTB who participated in both comparisons.
CCM.P-K15 and CCM.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 x 10-4 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-4 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-4 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-3 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-3 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 3.0 x 10-2 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 9.0 x 10-2 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 0.3 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.
CCM.P-K15, CCM.P-K15.1 and EURAMET.M.P-K15.1
MEASURAND Pressure
NOMINAL VALUE 1.0 Pa
CCM.P-K15
The laboratory measurement obtained in CCM.P-K15 are listed in Sec. 5 of the CCM.P-K15 Final report.
CCM.P-K15.1
The laboratory measurement obtained in CCM.P-K15.1 are listed in Sec. 5 of the CCM.P-K15.1 Final report.
EURAMET.M.P-K15.1
The laboratory measurement obtained in ERURAMET.M.P-K15.1 are listed in Sec. of the EURAMET.M.P-K15.1 Final report.