CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 1
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 1
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 1
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -2.60 | 6.55 | ||
| LNE | 4.66 | 24.61 | ||
| RISE | 7.00 | 9.24 | ||
| NMIA | 1.31 | 4.09 | ||
| NIM | -2.17 | 11.91 | ||
| PTB | 0.59 | 9.31 | ||
| NMISA | 8.94 | 52.15 | ||
| INMETRO | 3.06 | 24.61 | ||
| VSL | -9.74 | 9.58 | ||
| NIST | 0.71 | 5.91 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | 6.53 | 9.16 | ||
| LNE | 1.28 | 15.13 | ||
| RISE | 3.35 | 8.53 | ||
| NMIA | -0.36 | 2.26 | ||
| NIM | -3.78 | 11.87 | ||
| PTB | -1.12 | 9.39 | ||
| NMISA | 30.91 | 36.98 | ||
| INMETRO | -1.00 | 24.64 | ||
| VSL | -4.44 | 7.41 | ||
| NIST | 0.60 | 5.91 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | 9.84 | 9.84 | ||
| LNE | -1.89 | 10.35 | ||
| RISE | 1.84 | 8.52 | ||
| NMIA | -1.07 | 2.39 | ||
| NIM | -2.01 | 9.39 | ||
| PTB | -1.20 | 9.39 | ||
| NMISA | 36.22 | 36.98 | ||
| INMETRO | -2.21 | 24.64 | ||
| VSL | 0.15 | 6.30 | ||
| NIST | 0.36 | 5.90 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -9.76 | 9.16 | ||
| LNE | 4.09 | 15.13 | ||
| RISE | 2.13 | 8.53 | ||
| NMIA | 1.67 | 2.25 | ||
| NIM | 1.21 | 11.87 | ||
| PTB | 1.61 | 9.39 | ||
| NMISA | -24.55 | 36.98 | ||
| INMETRO | 2.78 | 24.64 | ||
| VSL | -6.61 | 7.45 | ||
| NIST | -0.28 | 5.92 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -8.71 | 9.85 | ||
| LNE | 1.86 | 10.35 | ||
| RISE | -0.40 | 8.53 | ||
| NMIA | 1.05 | 2.40 | ||
| NIM | 2.25 | 9.39 | ||
| PTB | 1.10 | 9.39 | ||
| NMISA | -29.34 | 36.98 | ||
| INMETRO | 1.69 | 24.64 | ||
| VSL | -1.53 | 5.79 | ||
| NIST | -0.22 | 5.89 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 1
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -5.65 | 6.50 | ||
| LNE | 3.13 | 24.59 | ||
| RISE | 5.82 | 9.20 | ||
| NMIA | 3.08 | 3.98 | ||
| NIM | 0.84 | 11.86 | ||
| PTB | 2.09 | 9.27 | ||
| NMISA | 13.71 | 56.89 | ||
| INMETRO | 16.27 | 24.59 | ||
| VSL | -9.74 | 8.91 | ||
| NIST | -2.15 | 9.22 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | 4.54 | 9.14 | ||
| LNE | -0.34 | 15.12 | ||
| RISE | 2.22 | 8.52 | ||
| NMIA | 0.15 | 2.19 | ||
| NIM | -2.99 | 11.85 | ||
| PTB | -1.86 | 9.38 | ||
| NMISA | 37.24 | 39.82 | ||
| INMETRO | 9.79 | 24.63 | ||
| VSL | -4.39 | 6.65 | ||
| NIST | 1.15 | 8.84 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lead
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | 7.68 | 9.83 | ||
| LNE | -1.25 | 11.30 | ||
| RISE | -0.35 | 8.51 | ||
| NMIA | -1.22 | 2.33 | ||
| NIM | -0.01 | 9.98 | ||
| PTB | -2.42 | 9.38 | ||
| NMISA | 31.34 | 35.08 | ||
| INMETRO | 2.54 | 24.63 | ||
| VSL | 0.49 | 5.60 | ||
| NIST | 3.44 | 8.39 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -11.23 | 9.14 | ||
| LNE | 4.54 | 15.56 | ||
| RISE | 2.50 | 8.52 | ||
| NMIA | 2.37 | 2.19 | ||
| NIM | 2.97 | 11.85 | ||
| PTB | 3.36 | 9.38 | ||
| NMISA | -6.43 | 39.82 | ||
| INMETRO | 5.09 | 24.63 | ||
| VSL | -7.06 | 6.67 | ||
| NIST | -6.03 | 8.56 |
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lag
Degrees of equivalence represented by Di and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).
| LABi | Di | Uneg,i | Upos,i | |
|---|---|---|---|---|
μW/(VA) |
μW/(VA) |
μW/(VA) |
||
| CENAM | -7.89 | 9.83 | ||
| LNE | 2.66 | 10.34 | ||
| RISE | 0.88 | 8.51 | ||
| NMIA | 1.34 | 2.34 | ||
| NIM | 0.30 | 9.38 | ||
| PTB | 2.71 | 9.38 | ||
| NMISA | -27.06 | 35.08 | ||
| INMETRO | -1.39 | 24.63 | ||
| VSL | -1.54 | 5.65 | ||
| NIST | -4.48 | 8.36 |
| Metrology area, Sub-field | Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer |
| Description | AC power at 50/60 Hz |
| Time of measurements | 2026 - 2027 |
| Status | Measurements in progress |
| References | |
| Measurand | AC power at 53 Hz |
| Parameters | Voltage: 120 V; Current: 5 A; Power factor: 1.0; 0.5 Lead; 0.5 Lag; 0.0 Lead; 0.0 Lag |
| Comparison type | Key Comparison |
| Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
| Conducted by | APMP (Asia Pacific Metrology Programme) |
| Comments | Star scheme - each participant to send own traveling standard to NMIA. |
| Pilot institute |
NMIA
National Measurement Institute, Australia Australia |
| Contact person | I. Budovsky +61 2 8467 3541 |
| Pilot laboratory | |
|---|---|
| NMIA |
National Measurement Institute, Australia, Australia, APMP |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 1
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -57.2 μW/(VA) uR_TS A = 1.5 μW/(VA)
xR_TS B = 81.6 μW/(VA) uR_TS B = 1.6 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lead
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -66.0 μW/(VA) uR_TS A = 1.2 μW/(VA)
xR_TS B = 68.9 μW/(VA) uR_TS B = 1.4 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lead
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -43.6 μW/(VA) uR_TS A = 1.2 μW/(VA)
xR_TS B = 32.1 μW/(VA) uR_TS B = 1.4 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lag
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = 9.4 μW/(VA) uR_TS A = 1.2 μW/(VA)
xR_TS B = 12.7 μW/(VA) uR_TS B = 1.4 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lag
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = 41.8 μW/(VA) uR_TS A = 1.15 μW/(VA)
xR_TS B = -34.4 μW/(VA) uR_TS B = 1.35 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 1
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -54.9 μW/(VA) uR_TS A = 1.55 μW/(VA)
xR_TS B = 85.8 μW/(VA) uR_TS B = 1.65 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lead
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -65.3 μW/(VA) uR_TS A = 1.25 μW/(VA)
xR_TS B = 74.5 μW/(VA) uR_TS B = 1.45 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lead
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = -44.4 μW/(VA) uR_TS A = 1.2 μW/(VA)
xR_TS B = 36.3 μW/(VA) uR_TS B = 1.4 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lag
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = 11.5 μW/(VA) uR_TS A = 1.25 μW/(VA)
xR_TS B = 12.1 μW/(VA) uR_TS B = 1.45 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lag
The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.
xR_TS A = 42.5 μW/(VA) uR_TS A = 1.2 μW/(VA)
xR_TS B = -38.8 μW/(VA) uR_TS B = 1.4 μW/(VA)
The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.
Di and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 1
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling standard TS A | Travelling standard TS B | ||||||||
| xi | ui | xi | ui | ||||||
| Labi | μW/(VA) | μW/(VA) | Labi | μW/(VA) | μW/(VA) | ||||
| CENAM | -63.0 | 7.1 | CENAM | 76.8 | 7.1 | ||||
| LNE | -56.7 | 26.0 | LNE | 86.6 | 26.0 | ||||
| RISE | -53.3 | 9.9 | RISE | 88.3 | 9.9 | ||||
| NMIA | -56.8 | 4.7 | NMIA | 81.3 | 4.7 | ||||
| NIM | -60.7 | 12.0 | NIM | 69.7 | 16.0 | ||||
| PTB | -56.2 | 10.0 | PTB | 81.8 | 10.0 | ||||
| NMISA | -60.0 | 55.0 | NMISA | 103.0 | 55.0 | ||||
| INMETRO | -50.0 | 26.0 | INMETRO | 83.0 | 26.0 | ||||
| VSL | -64.9 | 10.3 | VSL | 73.2 | 10.2 | ||||
| NIST | -53.2 | 6.3 | NIST | 87.1 | 6.3 | ||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lead
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -59.8 | 9.7 | CENAM | 72.7 | 9.7 | |||||
| LNE | -67.1 | 16.0 | LNE | 70.8 | 16.0 | |||||
| RISE | -63.4 | 9.1 | RISE | 71.1 | 9.1 | |||||
| NMIA | -66.4 | 2.9 | NMIA | 66.2 | 2.9 | |||||
| NIM | -70.4 | 12.0 | NIM | 62.0 | 16.0 | |||||
| PTB | -64.6 | 10.0 | PTB | 64.4 | 10.0 | |||||
| NMISA | -33.0 | 39.0 | NMISA | 98.0 | 39.0 | |||||
| INMETRO | -63.0 | 26.0 | INMETRO | 65.0 | 26.0 | |||||
| VSL | -70.0 | 7.9 | VSL | 66.1 | 7.9 | |||||
| NIST | -66.3 | 6.4 | NIST | 76.5 | 6.4 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lead
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -32.3 | 10.5 | CENAM | 39.9 | 10.5 | |||||
| LNE | -45.0 | 11.0 | LNE | 29.6 | 11.0 | |||||
| RISE | -40.8 | 9.1 | RISE | 32.6 | 9.1 | |||||
| NMIA | -44.3 | 3.1 | NMIA | 29.2 | 3.1 | |||||
| NIM | -46.2 | 10.0 | NIM | 31.0 | 10.0 | |||||
| PTB | -42.2 | 10.0 | PTB | 27.2 | 10.0 | |||||
| NMISA | -8.0 | 39.0 | NMISA | 69.0 | 39.0 | |||||
| INMETRO | -44.0 | 26.0 | INMETRO | 28.0 | 26.0 | |||||
| VSL | -44.1 | 6.7 | VSL | 33.9 | 7.0 | |||||
| NIST | -45.8 | 6.4 | NIST | 37.9 | 6.4 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0.5 lag
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -3.3 | 9.7 | CENAM | 3.7 | 9.7 | |||||
| LNE | 11.7 | 16.0 | LNE | 16.7 | 16.0 | |||||
| RISE | 9.3 | 9.1 | RISE | 15.8 | 9.1 | |||||
| NMIA | 10.1 | 2.9 | NMIA | 15.2 | 2.9 | |||||
| NIM | 9.8 | 12.0 | NIM | 7.7 | 16.0 | |||||
| PTB | 8.8 | 10.0 | PTB | 17.4 | 10.0 | |||||
| NMISA | -3.0 | 39.0 | NMISA | -24.0 | 39.0 | |||||
| INMETRO | 12.0 | 26.0 | INMETRO | 17.0 | 26.0 | |||||
| VSL | 4.6 | 6.7 | VSL | 5.9 | 7.8 | |||||
| NIST | 13.4 | 6.4 | NIST | 10.6 | 6.4 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 120 V, 5 A, 53 Hz, power factor 0 lag
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | 31.7 | 10.5 | CENAM | -41.0 | 10.5 | |||||
| LNE | 43.5 | 11.0 | LNE | -32.2 | 11.0 | |||||
| RISE | 40.4 | 9.1 | RISE | -33.2 | 9.1 | |||||
| NMIA | 42.5 | 3.1 | NMIA | -31.7 | 3.1 | |||||
| NIM | 44.8 | 10.0 | NIM | -33.2 | 10.0 | |||||
| PTB | 40.5 | 10.0 | PTB | -29.7 | 10.0 | |||||
| NMISA | 5.0 | 39.0 | NMISA | -56.0 | 39.0 | |||||
| INMETRO | 41.0 | 26.0 | INMETRO | -30.0 | 26.0 | |||||
| VSL | 41.0 | 6.3 | VSL | -37.3 | 6.2 | |||||
| NIST | 44.2 | 6.4 | NIST | -40.0 | 6.4 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 1
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -63.8 | 7.1 | CENAM | 78.0 | 7.1 | |||||
| LNE | -55.7 | 26.0 | LNE | 88.9 | 26.0 | |||||
| RISE | -51.8 | 9.9 | RISE | 90.9 | 9.9 | |||||
| NMIA | -51.9 | 4.7 | NMIA | 86.1 | 4.7 | |||||
| NIM | -55.1 | 12.0 | NIM | 82.0 | 16.0 | |||||
| PTB | -52.5 | 10.0 | PTB | 87.5 | 10.0 | |||||
| NMISA | -44.0 | 60.0 | NMISA | 103.0 | 60.0 | |||||
| INMETRO | -36.0 | 26.0 | INMETRO | 102.0 | 26.0 | |||||
| VSL | -64.0 | 9.7 | VSL | 79.0 | 9.6 | |||||
| NIST | -53.9 | 9.8 | NIST | 88.6 | 9.8 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lead
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -60.3 | 9.7 | CENAM | 75.2 | 9.7 | |||||
| LNE | -67.2 | 16.0 | LNE | 73.8 | 16.0 | |||||
| RISE | -63.7 | 9.1 | RISE | 75.3 | 9.1 | |||||
| NMIA | -64.8 | 2.9 | NMIA | 70.8 | 2.9 | |||||
| NIM | -68.4 | 12.0 | NIM | 75.5 | 16.0 | |||||
| PTB | -63.9 | 10.0 | PTB | 68.2 | 10.0 | |||||
| NMISA | -29.0 | 42.0 | NMISA | 113.0 | 42.0 | |||||
| INMETRO | -54.0 | 26.0 | INMETRO | 84.0 | 26.0 | |||||
| VSL | -70.6 | 7.2 | VSL | 73.6 | 7.1 | |||||
| NIST | -67.1 | 9.3 | NIST | 85.8 | 9.5 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lead
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -34.1 | 10.5 | CENAM | 40.4 | 10.5 | |||||
| LNE | -44.6 | 12.0 | LNE | 33.8 | 12.0 | |||||
| RISE | -43.7 | 9.1 | RISE | 34.4 | 9.1 | |||||
| NMIA | -44.9 | 3.1 | NMIA | 32.0 | 3.1 | |||||
| NIM | -46.9 | 10.0 | NIM | 40.0 | 10.0 | |||||
| PTB | -43.1 | 10.0 | PTB | 28.6 | 10.0 | |||||
| NMISA | -23.0 | 37.0 | NMISA | 78.0 | 37.0 | |||||
| INMETRO | -41.0 | 26.0 | INMETRO | 38.0 | 26.0 | |||||
| VSL | -44.9 | 6.1 | VSL | 39.0 | 6.2 | |||||
| NIST | -46.2 | 9.0 | NIST | 47.9 | 9.0 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0.5 lag
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | -3.4 | 9.7 | CENAM | 2.6 | 9.7 | |||||
| LNE | 14.2 | 17.0 | LNE | 16.2 | 16.0 | |||||
| RISE | 12.0 | 9.1 | RISE | 15.2 | 9.1 | |||||
| NMIA | 12.8 | 2.9 | NMIA | 15.2 | 2.9 | |||||
| NIM | 13.4 | 12.0 | NIM | 6.2 | 16.0 | |||||
| PTB | 11.7 | 10.0 | PTB | 19.7 | 10.0 | |||||
| NMISA | 4.0 | 42.0 | NMISA | 7.0 | 42.0 | |||||
| INMETRO | 17.0 | 26.0 | INMETRO | 18.0 | 26.0 | |||||
| VSL | 5.9 | 7.2 | VSL | 4.9 | 7.2 | |||||
| NIST | 12.2 | 9.1 | NIST | 1.4 | 9.1 | |||||
CCEM-K5.2017
MEASURAND Ratio of power error divided by apparent power
PARAMETERS 240 V, 5 A, 53 Hz, power factor 0 lag
xi measurement value reported by laboratory i, Labi
ui combined standard uncertainty of xi
| Travelling Standard TS A | Travelling Standard TS B | |||||||||
| Labi | xi | ui | Labi | xi | ui | |||||
| μW/(VA) | μW/(VA) | μW/(VA) | μW/(VA) | |||||||
| CENAM | 32.0 | 10.5 | CENAM | -43.1 | 10.5 | |||||
| LNE | 45.0 | 11.0 | LNE | -35.9 | 11.0 | |||||
| RISE | 42.1 | 9.1 | RISE | -35.9 | 9.1 | |||||
| NMIA | 43.2 | 3.1 | NMIA | -34.3 | 3.1 | |||||
| NIM | 45.4 | 10.0 | NIM | -42.3 | 10.0 | |||||
| PTB | 41.5 | 10.0 | PTB | -30.8 | 10.0 | |||||
| NMISA | 32.0 | 37.0 | NMISA | -83.0 | 37.0 | |||||
| INMETRO | 40.0 | 26.0 | INMETRO | -39.0 | 26.0 | |||||
| VSL | 41.6 | 6.2 | VSL | -41.5 | 6.1 | |||||
| NIST | 43.2 | 8.9 | NIST | -51.7 | 9.0 | |||||