CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 1

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 1
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0.5 lead
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0 lead
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0.5 lag
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0 lag
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 1

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 1
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0.5 lead
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0 lead
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0.5 lag
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

Power factor 0.5 lag
Di / μW/(VA)
Participating institutes

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 1

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -2.60 6.55
LNE 4.66 24.61
RISE 7.00 9.24
NMIA 1.31 4.09
NIM -2.17 11.91
PTB 0.59 9.31
NMISA 8.94 52.15
INMETRO 3.06 24.61
VSL -9.74 9.58
NIST 0.71 5.91
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM 6.53 9.16
LNE 1.28 15.13
RISE 3.35 8.53
NMIA -0.36 2.26
NIM -3.78 11.87
PTB -1.12 9.39
NMISA 30.91 36.98
INMETRO -1.00 24.64
VSL -4.44 7.41
NIST 0.60 5.91
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM 9.84 9.84
LNE -1.89 10.35
RISE 1.84 8.52
NMIA -1.07 2.39
NIM -2.01 9.39
PTB -1.20 9.39
NMISA 36.22 36.98
INMETRO -2.21 24.64
VSL 0.15 6.30
NIST 0.36 5.90
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -9.76 9.16
LNE 4.09 15.13
RISE 2.13 8.53
NMIA 1.67 2.25
NIM 1.21 11.87
PTB 1.61 9.39
NMISA -24.55 36.98
INMETRO 2.78 24.64
VSL -6.61 7.45
NIST -0.28 5.92
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -8.71 9.85
LNE 1.86 10.35
RISE -0.40 8.53
NMIA 1.05 2.40
NIM 2.25 9.39
PTB 1.10 9.39
NMISA -29.34 36.98
INMETRO 1.69 24.64
VSL -1.53 5.79
NIST -0.22 5.89
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 1

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -5.65 6.50
LNE 3.13 24.59
RISE 5.82 9.20
NMIA 3.08 3.98
NIM 0.84 11.86
PTB 2.09 9.27
NMISA 13.71 56.89
INMETRO 16.27 24.59
VSL -9.74 8.91
NIST -2.15 9.22
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM 4.54 9.14
LNE -0.34 15.12
RISE 2.22 8.52
NMIA 0.15 2.19
NIM -2.99 11.85
PTB -1.86 9.38
NMISA 37.24 39.82
INMETRO 9.79 24.63
VSL -4.39 6.65
NIST 1.15 8.84
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lead

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM 7.68 9.83
LNE -1.25 11.30
RISE -0.35 8.51
NMIA -1.22 2.33
NIM -0.01 9.98
PTB -2.42 9.38
NMISA 31.34 35.08
INMETRO 2.54 24.63
VSL 0.49 5.60
NIST 3.44 8.39
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -11.23 9.14
LNE 4.54 15.56
RISE 2.50 8.52
NMIA 2.37 2.19
NIM 2.97 11.85
PTB 3.36 9.38
NMISA -6.43 39.82
INMETRO 5.09 24.63
VSL -7.06 6.67
NIST -6.03 8.56
Participating institutes
CCEM-K5.2017

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lag

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in μW/(VA).

LABi Di Uneg,i Upos,i
μW/(VA)
μW/(VA)
μW/(VA)
CENAM -7.89 9.83
LNE 2.66 10.34
RISE 0.88 8.51
NMIA 1.34 2.34
NIM 0.30 9.38
PTB 2.71 9.38
NMISA -27.06 35.08
INMETRO -1.39 24.63
VSL -1.54 5.65
NIST -4.48 8.36
Participating institutes
CCEM-K5.2017
Comparison
Comparison close
EURAMET.EM-K5.2018
Metrology area, Sub-field Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Description AC power
Time of measurements 2019 - 2020
Status Report in progress, draft A
References

Technical Protocol

Measurand Calibration error of the travelling standard when measuring active power, expressed in μW/VA
Parameters

frequency 53 Hz

rms voltage 120 V & 240 V

rm current 5 A

power factor 1.0, 0.5 lead & lag, 0 lead & lag.

Transfer device Two traveling reference standards of the type RADIAN RD-22-332S
Comparison type Key Comparison
Consultative Committee CCEM (Consultative Committee for Electricity and Magnetism)
Conducted by EURAMET (European Association of National Metrology Institutes)
RMO Internal Identifier Euramet 1451
Comments This comparison on AC power is organised to link European national metrology institutes to the currently running CCEM-K5.2017 comparison.
Pilot institute VSL
VSL
Netherlands
Contact person Helko van den BROM

First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
VSL

VSL, Netherlands, EURAMET

AS METROSERT

Central Office of Metrology, Estonia, EURAMET

BEV

Bundesamt für Eich- und Vermessungswesen, Austria, EURAMET

BIM

Bulgarian Institute of Metrology, Bulgaria, EURAMET

CEM

Centro Español de Metrologia, Spain, EURAMET

CMI

Czech Metrology Institute, Czechia, EURAMET

EIM

Hellenic Institute of Metrology, Greece, EURAMET

GUM

Glowny Urzad Miar, Central Office of Measures, Poland, EURAMET

INM

National Institute of Metrology, Romania, EURAMET

INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

JV

Justervesenet, Norway, EURAMET

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

METAS

Federal Institute of Metrology, Switzerland, EURAMET

MIKES

VTT Technical Research Centre of Finland Ltd, Centre for Metrology/Mittatekniikan keskus, Finland, EURAMET

MIRS/SIQ/Metrology

MIRS/Slovenian Institute of Quality and Metrology/Metrology, Slovenia, EURAMET

NPL

National Physical Laboratory, United Kingdom, EURAMET

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

RISE

Research Institutes of Sweden AB, Sweden, EURAMET

SE "Ukrmetrteststandard"

State Enterprise "Ukrmetrteststandard", Ukraine, EURAMET

SMU

Slovensky Metrologicky Ustav, Slovakia, EURAMET

Trescal

Trescal Ltd, Denmark, EURAMET

UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 1

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -57.2 μW/(VA)     uR_TS A = 1.5 μW/(VA)

                              xR_TS B = 81.6 μW/(VA)     uR_TS B = 1.6 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lead

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -66.0 μW/(VA)     uR_TS A = 1.2 μW/(VA)

                              xR_TS B = 68.9 μW/(VA)     uR_TS B = 1.4 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lead

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -43.6 μW/(VA)     uR_TS A = 1.2 μW/(VA)

                              xR_TS B = 32.1 μW/(VA)     uR_TS B = 1.4 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lag

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = 9.4 μW/(VA)     uR_TS A = 1.2 μW/(VA)

                              xR_TS B = 12.7 μW/(VA)     uR_TS B = 1.4 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lag

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = 41.8 μW/(VA)     uR_TS A = 1.15 μW/(VA)

                              xR_TS B = -34.4 μW/(VA)     uR_TS B = 1.35 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 1

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -54.9 μW/(VA)     uR_TS A = 1.55 μW/(VA)

                              xR_TS B = 85.8 μW/(VA)     uR_TS B = 1.65 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lead

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -65.3 μW/(VA)     uR_TS A = 1.25 μW/(VA)

                              xR_TS B = 74.5 μW/(VA)     uR_TS B = 1.45 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lead

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = -44.4 μW/(VA)     uR_TS A = 1.2 μW/(VA)

                              xR_TS B = 36.3 μW/(VA)     uR_TS B = 1.4 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lag

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = 11.5 μW/(VA)     uR_TS A = 1.25 μW/(VA)

                              xR_TS B = 12.1 μW/(VA)     uR_TS B = 1.45 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lag

 

The key comparison reference values xR_TS A and xR_TS B and their associated standard uncertainty uR_TS A and uR_TS B are computed for each of the travelling standards TS A and TS B using the least squares method from the participants reported results.

 

        xR_TS A = 42.5 μW/(VA)     uR_TS A = 1.2 μW/(VA)

                              xR_TS B = -38.8 μW/(VA)     uR_TS B = 1.4 μW/(VA)

The two resulting degrees of equivalence for the two travelling standards for each laboratory i were combined to a single, merged degree of equivalence according to equations (13) and (14) of the CCEM-K5.2017 Final report.

Di  and its expanded uncertainty Ui at a 95 % level of confidence, are both expressed in μW/(VA)

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 1

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling standard TS A         Travelling standard TS B    
    xi ui         xi ui
  Labi μW/(VA) μW/(VA)       Labi μW/(VA) μW/(VA)
  CENAM -63.0 7.1       CENAM 76.8 7.1
  LNE -56.7 26.0       LNE 86.6 26.0
  RISE -53.3 9.9       RISE 88.3 9.9
  NMIA -56.8 4.7       NMIA 81.3 4.7
  NIM -60.7 12.0       NIM 69.7 16.0
  PTB -56.2 10.0       PTB 81.8 10.0
  NMISA -60.0 55.0       NMISA 103.0 55.0
  INMETRO -50.0 26.0       INMETRO 83.0 26.0
  VSL -64.9 10.3       VSL 73.2 10.2
  NIST -53.2 6.3       NIST 87.1 6.3

 

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lead

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -59.8 9.7         CENAM 72.7 9.7
  LNE -67.1 16.0         LNE 70.8 16.0
  RISE -63.4 9.1         RISE 71.1 9.1
  NMIA -66.4 2.9         NMIA 66.2 2.9
  NIM -70.4 12.0         NIM 62.0 16.0
  PTB -64.6 10.0         PTB 64.4 10.0
  NMISA -33.0 39.0         NMISA 98.0 39.0
  INMETRO -63.0 26.0         INMETRO 65.0 26.0
  VSL -70.0 7.9         VSL 66.1 7.9
  NIST -66.3 6.4         NIST 76.5 6.4

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lead

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -32.3 10.5         CENAM 39.9 10.5
  LNE -45.0 11.0         LNE 29.6 11.0
  RISE -40.8 9.1         RISE 32.6 9.1
  NMIA -44.3 3.1         NMIA 29.2 3.1
  NIM -46.2 10.0         NIM 31.0 10.0
  PTB -42.2 10.0         PTB 27.2 10.0
  NMISA -8.0 39.0         NMISA 69.0 39.0
  INMETRO -44.0 26.0         INMETRO 28.0 26.0
  VSL -44.1 6.7         VSL 33.9 7.0
  NIST -45.8 6.4         NIST 37.9 6.4

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0.5 lag

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -3.3 9.7         CENAM 3.7 9.7
  LNE 11.7 16.0         LNE 16.7 16.0
  RISE 9.3 9.1         RISE 15.8 9.1
  NMIA 10.1 2.9         NMIA 15.2 2.9
  NIM 9.8 12.0         NIM 7.7 16.0
  PTB 8.8 10.0         PTB 17.4 10.0
  NMISA -3.0 39.0         NMISA -24.0 39.0
  INMETRO 12.0 26.0         INMETRO 17.0 26.0
  VSL 4.6 6.7         VSL 5.9 7.8
  NIST 13.4 6.4         NIST 10.6 6.4

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        120 V, 5 A, 53 Hz, power factor 0 lag

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM 31.7 10.5         CENAM -41.0 10.5
  LNE 43.5 11.0         LNE -32.2 11.0
  RISE 40.4 9.1         RISE -33.2 9.1
  NMIA 42.5 3.1         NMIA -31.7 3.1
  NIM 44.8 10.0         NIM -33.2 10.0
  PTB 40.5 10.0         PTB -29.7 10.0
  NMISA 5.0 39.0         NMISA -56.0 39.0
  INMETRO 41.0 26.0         INMETRO -30.0 26.0
  VSL 41.0 6.3         VSL -37.3 6.2
  NIST 44.2 6.4         NIST -40.0 6.4

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 1

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -63.8 7.1         CENAM 78.0 7.1
  LNE -55.7 26.0         LNE 88.9 26.0
  RISE -51.8 9.9         RISE 90.9 9.9
  NMIA -51.9 4.7         NMIA 86.1 4.7
  NIM -55.1 12.0         NIM 82.0 16.0
  PTB -52.5 10.0         PTB 87.5 10.0
  NMISA -44.0 60.0         NMISA 103.0 60.0
  INMETRO -36.0 26.0         INMETRO 102.0 26.0
  VSL -64.0 9.7         VSL 79.0 9.6
  NIST -53.9 9.8         NIST 88.6 9.8

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lead

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -60.3 9.7         CENAM 75.2 9.7
  LNE -67.2 16.0         LNE 73.8 16.0
  RISE -63.7 9.1         RISE 75.3 9.1
  NMIA -64.8 2.9         NMIA 70.8 2.9
  NIM -68.4 12.0         NIM 75.5 16.0
  PTB -63.9 10.0         PTB 68.2 10.0
  NMISA -29.0 42.0         NMISA 113.0 42.0
  INMETRO -54.0 26.0         INMETRO 84.0 26.0
  VSL -70.6 7.2         VSL 73.6 7.1
  NIST -67.1 9.3         NIST 85.8 9.5

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lead

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -34.1 10.5         CENAM 40.4 10.5
  LNE -44.6 12.0         LNE 33.8 12.0
  RISE -43.7 9.1         RISE 34.4 9.1
  NMIA -44.9 3.1         NMIA 32.0 3.1
  NIM -46.9 10.0         NIM 40.0 10.0
  PTB -43.1 10.0         PTB 28.6 10.0
  NMISA -23.0 37.0         NMISA 78.0 37.0
  INMETRO -41.0 26.0         INMETRO 38.0 26.0
  VSL -44.9 6.1         VSL 39.0 6.2
  NIST -46.2 9.0         NIST 47.9 9.0

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0.5 lag

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM -3.4 9.7         CENAM 2.6 9.7
  LNE 14.2 17.0         LNE 16.2 16.0
  RISE 12.0 9.1         RISE 15.2 9.1
  NMIA 12.8 2.9         NMIA 15.2 2.9
  NIM 13.4 12.0         NIM 6.2 16.0
  PTB 11.7 10.0         PTB 19.7 10.0
  NMISA 4.0 42.0         NMISA 7.0 42.0
  INMETRO 17.0 26.0         INMETRO 18.0 26.0
  VSL 5.9 7.2         VSL 4.9 7.2
  NIST 12.2 9.1         NIST 1.4 9.1

CCEM-K5.2017

 

MEASURAND   Ratio of power error divided by apparent power

PARAMETERS        240 V, 5 A, 53 Hz, power factor 0 lag

 

xi   measurement value reported by laboratory i, Labi

ui   combined standard uncertainty of xi

 

 

  Travelling Standard TS A         Travelling Standard TS B
  Labi xi ui         Labi xi ui
  μW/(VA) μW/(VA)         μW/(VA) μW/(VA)
  CENAM 32.0 10.5         CENAM -43.1 10.5
  LNE 45.0 11.0         LNE -35.9 11.0
  RISE 42.1 9.1         RISE -35.9 9.1
  NMIA 43.2 3.1         NMIA -34.3 3.1
  NIM 45.4 10.0         NIM -42.3 10.0
  PTB 41.5 10.0         PTB -30.8 10.0
  NMISA 32.0 37.0         NMISA -83.0 37.0
  INMETRO 40.0 26.0         INMETRO -39.0 26.0
  VSL 41.6 6.2         VSL -41.5 6.1
  NIST 43.2 8.9         NIST -51.7 9.0