CCEM-K5.2017
Metrology area, Sub-field Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Description Active power at 53 Hz
Time of measurements 2018 - 2022
Status Approved for equivalence
Final Reports of the comparisons
Measurand Ratio of power errordivided by apparent power expressed in µW/VA
Parameters Voltage: 120 V and 240 V
Current: 5 A
Frequency: 53 Hz
Five power factors: 1, 0.5 lead, 0.5 lag, 0 lead, 0 lag
Transfer device Two Radian RD22 standards
Comparison type Key Comparison
Consultative Committee CCEM (Consultative Committee for Electricity and Magnetism)
Conducted by CCEM (Consultative Committee for Electricity and Magnetism)
Comments
 
Pilot institute VSL
VSL
Netherlands
Contact person G. Rietveld

+31 (0) 15 269 1645
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
VSL

VSL, Netherlands, EURAMET

CENAM

Centro Nacional de Metrologia, Mexico, SIM

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

NIM

National Institute of Metrology, China, APMP

NIST

National Institute of Standards and Technology, United States, SIM

NMIA

National Measurement Institute, Australia, Australia, APMP

NMISA

National Metrology Institute of South Africa, South Africa, AFRIMETS

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

RISE

Research Institutes of Sweden AB, Sweden, EURAMET