Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in (cd/V)/(cd/V).

Relative degrees of equivalence for luminous intensity
Di 
Participating institutes
Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in (cd/V)/(cd/V).

LABi Di Uneg,i Upos,i
(cd/V)/(cd/V)
(cd/V)/(cd/V)
(cd/V)/(cd/V)
NMIJ 0.0047 0.0051
NIM 0.0002 0.0032
PTB -0.0004 0.0030
METAS -0.0006 0.0061
NIST 0.0006 0.0043
NMIA -0.0018 0.0029
VNIIOFI -0.0073 0.0048
IO-CSIC -0.0011 0.0061
NPL 0.0034 0.0032
NMISA -0.0093 0.0132
NRC 0.0051 0.0123
Participating institutes
CCPR-K3.2014
Comparison
Comparison close
EURAMET.PR-K3.2020.1
Metrology area, Sub-field Photometry and Radiometry, Photometry
Description Luminous Intensity
Time of measurements 2026 - 2027
Status Protocol complete
Measurand Luminous Intensity
Transfer device Wi41 lamp
Comparison type Key Comparison
Consultative Committee CCPR (Consultative Committee for Photometry and Radiometry)
Conducted by EURAMET (European Association of National Metrology Institutes)
Pilot institute METAS
Federal Institute of Metrology
Switzerland
Contact person Florian Stuker

+41583870120
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
METAS

Federal Institute of Metrology, Switzerland, EURAMET

Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

The key comparison reference value xR and its associated standard uncertainty uR were calculated by applying a Mandel-Paule method to the participant results, those of the NMISA and LNE/LCE-Cnam excluded:

 

        xR = 86.256 cd/V     uR = 0.059 cd/V

 

The degree of equivalence of laboratory i relative to the key comparison reference value xR is given by a pair of terms, Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence where Ui = 2 ui, both expressed in (cd/V)/(cd/V).

Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

The measurement data are listed in Appendix D of the CCPR-K3.2014 Final Report.