Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

Degrees of equivalence represented by D and its expanded uncertainty Ui  (k = 2), both expressed in mg.

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui  (k =2), both expressed in mg.

 

 

 

 

GULFMET.M.M-K4
Metrology area, Sub-field Mass and related quantities, Mass Standards
Description Calibration
Time of measurements 2017 - 2018
Status Approved for equivalence
Final Reports of the comparisons
References

GULFMET.M.M-K4 Technical Protocol

Measurand Mass at 1 kg
Transfer device Stainless steel standard of 1 kg
Comparison type Key Comparison
Consultative Committee CCM (Consultative Committee for Mass and Related Quantities)
Conducted by GULFMET (Gulf Association for Metrology)
Comments Results published on 8 October 2020
Pilot institute UME
TÜBITAK Ulusal Metroloji Enstitüsü
Türkiye
Contact person B. Korutlu

+90 262 679 50 00
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

EMI

Emirates Metrology Institute, United Arab Emirates, GULFMET

INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

METAS

Federal Institute of Metrology, Switzerland, EURAMET

PAI

Public Authority for industry, Kuwait, GULFMET

QGOSM

Qatar General Organization for Standards and Metrology, Qatar, GULFMET

SASO-NMCC

National Measurement and Calibration Center - Saudi Standards, Metrology and Quality Organization, Saudi Arabia, GULFMET

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

CCM.M-K4

For each of the travelling mass standards, the key comparison reference value, xR, and its standard uncertainty, uR, were obtained using the generalized linear least-squares method as explained in section VII of the CCM.M-K4 Final Report.

The degree of equivalence of each laboratory i with respect to the reference value is given by a pair of terms:

Di and Ui its expanded uncertainty (k = 2), both expressed in mg.
Detailed information on the evaluation of Di and Ui may be found in section VIII of the Final Report.

There were no degrees of equivalence between pair of laboratories calculated for this comparison.

 

Linking SIM.M.M-K4 to CCM.M-K4

The results of the SIM.M.M-K4 comparison were linked to CCM.M-K4 via the CENAM and NRC. The linking procedure is described on pages 5 to 7 of the SIM.M.M-K4 Final Report.

 

Linking APMP.M.M-K4.1 to CCM.M-K4

KRISS participated in both key comparisons, APMP.M.M-K4.1 and CCM.M-K4, providing a link between the NMC, A*STAR result and the key comparison reference value of CCM.M-K4. The linkage process is described in Section 7 of the APMP.M.M-K4.1 Final Report.

 

Linking EURAMET.M.M-K4.2015 to CCM.M-K4

The results of the EURAMET.M.M-K4.2015 comparison were linked to CCM.M-K4 via the BEV, BIPM, LNE, METAS and NPL. The linkage process is described in Section 7 of the EURAMET.M.M-K4.2015 Final Report.

 

Linking GULFMET.M.M-K4 to CCM.M-K4

The results of the GULFMET.M.M-K4 comparison were linked to CCM.M-K4 via the INRIM, METAS and KRISS. The linkage process is described in Section 7 of the GULFMET.M.M-K4 Final Report.

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

CCM.M-K4

The key comparison was organized in four simultaneous “petals”. Each of the four participants within a petal received the same two travelling mass standards as follows:
Petal 1: Mass standards B5 and C1; Petal 2: Mass standards B6 and C2; Petal 3: Mass standards B7 and D1; Petal 4: Mass standards B8 and D2.

The pilot laboratory, the BIPM, carried out a comparison of the standards before the comparison started, and after completion of measurements within each petal.

xi : reported result obtained as the difference between the measurement of the mass standard carried out by laboratory i and its nominal value, and corrected for the drift of the travelling mass standard as explained on page 8 of the Final Report.
ui : combined standard uncertainty of xi

 

SIM.M.M-K4

The laboratory individual measurement results are given on page 3 of the SIM.M.M-K4 Final Report.

 

APMP.M.M-K4.1

The results reported by the particpants in APMP.M.M-K4.1 are given in section 6 of the APMP.M.M-K4.1 Final Report.

 

EURAMET.M.M-K4.2015

The results reported by the particpants in EURAMET.M.M-K4.2015 are given in Table 5 of the EURAMET.M.M-K4.2015 Final Report.

 

GULMET.M.M-K4

The results reported by the particpants in GULFMET.M.M-K4 are given in Table 5 of the GULFMET.M.M-K4 Final Report.