Comparison
Comparison close
Results
Comparison
Comparison close
Results
Comparison
Comparison close
RMO comparison
Linked comparison
APMP.M.FF-K2.a
Metrology area, Sub-field Mass and related quantities, Fluid Flow
Description Hydrocarbon liquid flow
Time of measurements 2010
Status Approved
Final Reports of the comparisons
Measurand Flow meter factors (dimensionless)
Flow: 5 l/s to 30 l/s

Transfer device One positive displacement meter
Comparison type Key Comparison
Consultative Committee CCM (Consultative Committee for Mass and Related Quantities)
Conducted by APMP (Asia Pacific Metrology Programme)
Comments

Results published on 20 January 2017

APMP.M.FF-K2.a results are linked to those of CCM.FF-K2.

Liquid hydrocarbon flow

Measurements are taken with two meters, designated as "Kral meter" and "Turbine meter", and in two different configurations (Configuration 1: a flow conditioner is placed upstream of the turbine meter; Configuration 2: the flow conditioner is removed), as explained in Section 2.2 on page 7 of the Final Report.

Pilot institute NMIJ AIST
National Metrology Institute of Japan
Japan
Contact person Takashi SHIMADA

+81 29 861 3816
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NMIA

National Measurement Institute, Australia, Australia, APMP

Comparison
Comparison close
Results
Comparison
Comparison close
Results