CCQM-K99

MEASURAND : pH value of an unknown phosphate buffer

Measurements at 15 °C, 25 °C, 37 °C. Optional: 5 °C and 50 °C.

NOMINAL VALUE : pH = 7.5

Degrees of equivalence Di and expanded uncertainty Ui (k = 2)

CCQM-K99

MEASURAND : pH value of an unknown phosphate buffer

Measurements at 15 °C, 25 °C, 37 °C. Optional: 5 °C and 50 °C.

NOMINAL VALUE : pH = 7.5

Degrees of equivalence Di and expanded uncertainty Ui (k = 2)

A printable Summary of Resuts is available in A4 format.

Comparison
Comparison close
CC comparison
Linked comparison
COOMET.QM-K99
Metrology area, Sub-field Chemistry and Biology, Electrochemistry
Description pH of phosphate buffer solution
Time of measurements 2026 - 2027
Status Planned
References

Technical protocol

Comparison presentation

Comparison registration form

Measurand pH
from 6.80 to 7.00
Parameters Measurement temperature: 25 °C (optionally 15 °C and 37 °C)
Transfer device Dedicated samples
Comparison type Key Comparison
Consultative Committee CCQM (Consultative Committee for Amount of Substance)
Conducted by COOMET (Euro-Asian Cooperation of National Metrological Institutions)
RMO Internal Identifier COOMET 630/RU/25
Comments The measurement method (primary method or secondary method using a differential potentiometric cell, or working method using a glass electrode pH-meter) is the choice of the each participant-laboratory based on its measurement capabilities. It is possible to use several methods, but only the results obtained by the primary method per temperature will be considered when calculating the key comparison reference value.
Pilot institute VNIIFTRI
Institute of Physical Technical and Radiotechnical Measurements, Rosstandart
Russian Federation
Contact person Narine Oganyan

+79017227886
Additional
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
VNIIFTRI

Institute of Physical Technical and Radiotechnical Measurements, Rosstandart, Russian Federation, COOMET

RCAM-Rostest

Research Center for Applied Metrology - Rostest, Russian Federation, COOMET

CCQM-K99

MEASURAND : pH value of an unknown phosphate buffer

Measurements at 15 °C, 25 °C, 37 °C. Optional: 5 °C and 50 °C.

NOMINAL VALUE : pH = 7.5

The key comparison reference value, pHR, is obtained by calculating the weighted mean including the institutes using primary standards for which the results passed a previously defined consistancy filter.

t = 15 °C : pHR = 7.5561 and uR = 0.0009

t = 25 °C : pHR = 7.5246 and uR = 0.0008

t = 37 °C : pHR = 7.5013 and uR = 0.0009

t =   5 °C : pHR = 7.6043 and uR = 0.0015

t = 50 °C : pHR = 7.4960 and uR = 0.0029

 

The degree of equivalence of each laboratory with respect to the key comparison reference value is given by a pair of terms: Di = (pHi - pHR) and Ui, its expanded uncertainty (k = 2), Ui = 2((1 - 2wi) ui2 + uR2)1/2, where wi represents the weight of laboratory i.

CCQM-K99

MEASURAND : pH value of an unknown phosphate buffer

Measurements at 15 °C, 25 °C, 37 °C. Optional: 5 °C and 50 °C.

NOMINAL VALUE : pH = 7.5

pHi : result of measurement carried out by laboratory i
ui : combined standard uncertainty (k = 1) of pHi