BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
Degrees of equivalence represented by Di = (xI - xR) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq.
Results given in absolute values.
BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
Degrees of equivalence represented by Di = (xI - xR) /xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.
Results given in relative values.
BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
Degrees of equivalence represented by Di = (xI - xR) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
kBq |
kBq |
kBq |
||
PTB | -7 | 35 |
Results given in absolute values.
BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
Degrees of equivalence represented by Di = (xI - xR) /xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
kBq/MBq |
kBq/MBq |
kBq/MBq |
||
PTB | -1.1 | 5.8 |
Results given in relative values.
Metrology area, Sub-field | Ionizing Radiation, Section II (Measurement of Radionuclides) |
Description | Activity of radionuclide Ag-110m |
Time of measurements | 1983 - |
Status | Continuous, approved for equivalence |
Final Reports of the comparisons | |
Measurand | SIR equivalent activity |
Transfer device | Radioactive solution |
Comparison type | Key Comparison |
Consultative Committee | CCRI (Consultative Committee for Ionizing Radiation) |
Conducted by | BIPM (Bureau International des Poids et Mesures) |
Comments | SIR: Système International de Référence, International Reference System Most recent results published on 22 December 2020 Earlier reports and the status of not yet completed resulsts can be found in the participants list. Results older than 20 years are no longer considered valid (see pages 37 and 38 of the CCRI Report of its 18th meeting in 2003). |
Pilot institute |
BIPM
Bureau International des Poids et Mesures BIPM - International Organization |
Contact person | Carine Michotte +33 (0) 1 45 07 70 85 |
Pilot laboratory | |
---|---|
BIPM |
Bureau International des Poids et Mesures, BIPM - International Organization, N/A |
BNM-LNHB |
Bureau National de Métrologie - Laboratoire National Henri Becquerel, France, EURAMET |
2001 |
IFIN-HH |
"Horia Hulubei" National Institute of Research and Development for Physics and Nuclear Engineering, Romania, EURAMET |
1983 |
NIST |
National Institute of Standards and Technology, United States, SIM |
1988 |
NPL |
National Physical Laboratory, United Kingdom, EURAMET |
1993 |
OMH |
Országos Mérésügyi Hivatal; Subsequently MKEH, now BKFH, Hungary, EURAMET |
2000 |
PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
2015 |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
The key comparison reference value xR for this radionuclide is estimated to be
xR = 5980.8 kBq with a standard uncertainty, uR = 6.4 kBq (see Section 4.1 of the Final Report).
Degrees of equivalence represented by Di = (xI - xR) and its expanded uncertainty Ui at a 95 % level of confidence are both expressed in kBq, where xi is the equivalent activity for laboratory i.
The Degrees of equivalence are also given in relative terms by Di = (xI - xR) /xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.
BIPM.RI(II)-K1.Ag-110m
MEASURAND SIR equivalent activity of Ag-110m
xi result of measurement carried out in the SIR for the sample submitted by laboratory i, Labi
ui (xi) combined standard uncertainty of xi
Labi | xi | u(xi) | Date of measurement | |
kBq | kBq | |||
PTB | 5974 | 19 | 2015-01-22 |