MEASURAND : Mass fraction of Arsenic in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

MEASURAND : Mass fraction of Boron in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

MEASURAND : Mass fraction of Cadmium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

 

Note:
DRCChem-LIPI = 0.468 µg/kg and URCChem-LIPI = 0.150 µg/kg
DKEBS = 0.589 µg/kg and UKEBS = 0.441 µg/kg

MEASURAND : Mass fraction of Calcium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in mg/kg

MEASURAND : Mass fraction of Chromium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

MEASURAND : Mass fraction of Hexavalent Chromium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

Degrees of equivalence expressed in relative terms

MEASURAND : Mass fraction of Arsenic in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

* the results from NIST, VNIIM, and KEBS are not included in the calculation of the key comparison reference value.

Results are presented under A4 printable format in Summary Results (PDF file).

MEASURAND : Mass fraction of Boron in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

* the results from KEBS are not included in the calculation of the key comparison reference value.

Results are presented under A4 printable format in Summary Results (PDF file).

MEASURAND : Mass fraction of Cadmium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

* the results from RCChem-LIPI and KEBS are not included in the calculation of the key comparison reference value.

Results are presented under A4 printable format in Summary Results (PDF file).

MEASURAND : Mass fraction of Calcium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in mg/kg

* the results from RCChem-LIPI are not included in the calculation of the key comparison reference value.

Results are presented under A4 printable format in Summary Results (PDF file).

MEASURAND : Mass fraction of Chromium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

* the results from KEBS are not included in the calculation of the key comparison reference value.

Results are presented under A4 printable format in Summary Results (PDF file).

MEASURAND : Mass fraction of Hexavalent Chromium in drinking water

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in µg/kg

Degrees of equivalence expressed in relative terms

Results are presented under A4 printable format in Summary Results (PDF file).

Comparison
Comparison close
CC comparison
Linked comparison
CCQM-K124
Metrology area, Sub-field Chemistry and Biology, Inorganics
Description Trace elements and Chromium speciation in drinking water
Time of measurements 2014 - 2015
Status Approved for equivalence
Final Reports of the comparisons
Measurand Mass fraction of As, B, Cr and Cd in µg/kg and Ca in mg/kg;
Mass fraction of Cr(VI) in µg/kg

Transfer device Dedicated samples
Comparison type Key Comparison
Consultative Committee CCQM (Consultative Committee for Amount of Substance)
Conducted by CCQM (Consultative Committee for Amount of Substance)
Comments

Results published on 31 March 2017

Trace elements and Chromium speciation in drinking water

Pilot institute GL
Government Laboratory
Hong Kong, China
Contact person Wai hong Fung

+852 2762 3853
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
GL

Government Laboratory, Hong Kong, China, APMP

BIM

Bulgarian Institute of Metrology, Bulgaria, EURAMET

CENAM

Centro Nacional de Metrologia, Mexico, SIM

DRICM

Designated Reference Institute for Chemical Measurements, Bangladesh, APMP

EXHM/GCSL-EIM

National Laboratory of Chemical Metrology/GCSL - Hellenic Institute of Metrology, Greece, EURAMET

HSA

Health Science Authority, Singapore, APMP

INACAL

National Institute for Quality, Peru, SIM

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

INRAP

Institut National de Recherche et d'Analyse Physico-Chimique, Tunisia, AFRIMETS

ISP

Instituto de Salud Pública, Chile, SIM

KEBS

Kenya Bureau of Standards, Kenya, AFRIMETS

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

LATU

Laboratorio Tecnologico del Uruguay, Uruguay, SIM

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

MIKES-SYKE

Finnish Environment Institute, Finland, EURAMET

MIRS/IJS/F-2,O-2

MIRS/Jozef Stefan Institute/Low and Medium Energy Physics F2, Environmental Sciences O2, Slovenia, EURAMET

NIM

National Institute of Metrology, China, APMP

NIMT

National Institute of Metrology (Thailand), Thailand, APMP

NIST

National Institute of Standards and Technology, United States, SIM

NMIA

National Measurement Institute, Australia, Australia, APMP

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NRC

National Research Council, Canada, SIM

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

RCChem-LIPI

Research Center for Chemistry – Indonesian Institute of Sciences, Indonesia, APMP

STD-ITDI

Standards and Testing Division, Industrial Technology Development Institute, Philippines, APMP

UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

VNIIM

D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET

MEASURAND : Mass fraction of Arsenic in drinking water

The key comparison reference value, xR, is calculated as the median of the participants’ results without the results from NIST, VNIIM, and KEBS. Its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part A).

xR = 5.346 µg/kg and uR = 0.012 µg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in µg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2 .
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Boron in drinking water

The key comparison reference value, xR, is calculated as the arithmetic mean of the participants’ results without the results from KEBS. Its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part A).

xR = 42.87 µg/kg and uR = 0.29 µg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in µg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2 .
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Cadmium in drinking water

The key comparison reference value, xR, is calculated as the median of the participants’ results without the results from KEBS and RCChem-LIPI. Its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part A).

xR = 0.352 µg/kg and uR = 0.003 µg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in µg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2 .
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Calcium in drinking water

The key comparison reference value, xR, is calculated as the median of the participants’ results without the results from RCChem-LIPI. Its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part A).

xR = 18.36 mg/kg and uR = 0.07 mg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in mg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2 .
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Chromium in drinking water

The key comparison reference value, xR, is calculated as the median of the participants’ results without the results from KEBS. Its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part A).

xR = 5.080 µg/kg and uR = 0.018 µg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in µg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2 .
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Hexavalent Chromium in drinking water

The key comparison reference value, xR, is calculated as the median of the participants’ results, and its standard uncertainty, uR, is computed as explained in section 5.3 of the Final Report (Part B).

xR = 62.67 µg/kg and uR = 0.329 µg/kg

The degree of equivalence of each laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in µg/kg: Di = (xi - xR) and Ui, its expanded uncertainty (k = 2) is calculated as explained in section 5.4 of the Final Report (Part B).
The degrees of equivalence are also expressed in relative terms.
No pair-wise degrees of equivalence are computed here.

 

 

MEASURAND : Mass fraction of Arsenic in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

MEASURAND : Mass fraction of Boron in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

MEASURAND : Mass fraction of Cadmium in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

MEASURAND : Mass fraction of Calcium in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

MEASURAND : Mass fraction of Chromium in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

MEASURAND : Mass fraction of Hexavalent Chromium in drinking water

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi