Comparison
Comparison close
Results
Comparison
Comparison close
Results
Comparison
Comparison close
RMO comparison
Linked comparison
EURAMET.EM-S39
Metrology area, Sub-field Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Description Frequency response of current shunts
Time of measurements 2013
Status Approved
Final Reports of the comparisons
References

EURAMET.EM-S39 Technical Protocol

Measurand Current: 30 mA, 100 mA, 300 mA, 1 A, 3 A, 5 A, 10 A and 20 A
Parameters Frequency: 10 Hz to 100 kHz (11 values)
Transfer device A set of current shunts
Comparison type Supplementary Comparison
Consultative Committee CCEM (Consultative Committee for Electricity and Magnetism)
Conducted by EURAMET (European Association of National Metrology Institutes)
Comments The current shunts are used as AC/DC current transfer standards in combination with planar multijunction thermal converters (PMJTCs). The measurements are conducted in such a way that the contribution of the PMJTC is eliminated.
 
Pilot institute JV
Justervesenet
Norway
Contact person Helge Malmbekk

+47 64 84 84 27
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
JV

Justervesenet, Norway, EURAMET

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET