BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs

 

Degrees of equivalence represented by Di = (xI - xR) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in MBq.

Equivalent activity of Cs-137
Di / MBq
Participating institutes

Results given in absolute values.

BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.

Equivalent activity of Cs-137
Di / (kBq/MBq)
Participating institutes

Results given in relative values

Comparison
Comparison close
Results

BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs

 

Degrees of equivalence represented by Di = (xI - xR) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in MBq.

LABi Di Uneg,i Upos,i
MBq
MBq
MBq
NMIJ 0.11 0.28
VNIIM -0.16 0.26
IFIN-HH 0.00 0.45
NMISA 0.10 0.19
BEV -0.21 0.39
NRC 0.29 0.33
TENMAK-NUKEN 0.07 0.85
BelGIM -0.39 0.55
SMU 0.16 0.63
Participating institutes
BIPM.RI(II)-K1.Cs-137
COOMET.RI(II)-K2.Cs-137

Results given in absolute values.

BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.

LABi Di Uneg,i Upos,i
kBq/MBq
kBq/MBq
kBq/MBq
NMIJ 4 10
VNIIM -5.8 9.4
IFIN-HH 0 16
NMISA 3.5 6.8
BEV -8 14
NRC 11 12
TENMAK-NUKEN 3 31
BelGIM -14 20
SMU 6 23
Participating institutes
BIPM.RI(II)-K1.Cs-137
COOMET.RI(II)-K2.Cs-137

Results given in relative values.

Comparison
Comparison close
BIPM comparison
Linked comparison
BIPM.RI(II)-K1.Cs-137
Metrology area, Sub-field Ionizing Radiation, Section II (Measurement of Radionuclides)
Description Activity of radionuclide Cs-137
Time of measurements 1976 -
Status Continuous, approved for equivalence
Final Reports of the comparisons
Measurand SIR equivalent activity
Transfer device Radioactive solution
Comparison type Key Comparison
Consultative Committee CCRI (Consultative Committee for Ionizing Radiation)
Conducted by BIPM (Bureau International des Poids et Mesures)
Comments SIR: Système International de Référence, International Reference System
Last update: 30 September 2024
COOMET.RI(II)-K2.Cs-137 results are linked to those of BIPM.RI(II)-K1.Cs-137
SIR equivalent activity of the radionuclide 137Cs
Pilot institute BIPM
Bureau International des Poids et Mesures
BIPM - International Organization
Contact person Carine Michotte

+33 (0) 1 45 07 70 85
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
BIPM

Bureau International des Poids et Mesures, BIPM - International Organization, N/A

ANSTO

Australian Nuclear Science and Technology Organisation, Australia, APMP

BARC

Bhabha Atomic Research Centre, India, APMP

BEV

Bundesamt für Eich- und Vermessungswesen, Austria, EURAMET

CMI-IIR

Czech Metrology Institute - Inspectorate for Ionizing Radiation, Czechia, EURAMET

CNEA

National Commission of Atomic Energy, Argentina, SIM

CSIR-NML

Council for Scientific and Industrial Research, National Metrology Laboratory (became NMISA in 2007), South Africa, AFRIMETS

IFIN-HH

"Horia Hulubei" National Institute of Research and Development for Physics and Nuclear Engineering, Romania, EURAMET

IRA

Institut Universitaire de Radiophysique Appliquée, Switzerland, EURAMET

IRMM

Institute for Reference Materials and Measurements, European Union, EURAMET

LNE-LNHB

Commissariat à l'énergie atomique / Laboratoire National Henri Becquerel, France, EURAMET

NIM

National Institute of Metrology, China, APMP

NIST

National Institute of Standards and Technology, United States, SIM

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NPL

National Physical Laboratory, United Kingdom, EURAMET

NRC

National Research Council, Canada, SIM

OMH

Országos Mérésügyi Hivatal; Subsequently MKEH, now BKFH, Hungary, EURAMET

P3KRBiN

Pusat Penelitian & Pengembangan Keselamatan Radiasi & Biomedika Nuklir, Indonesia, APMP

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

TENMAK-NUKEN

Nuclear Energy Research Institute, Türkiye, EURAMET

VNIIM

D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET

Comparison
Comparison close
Results

BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs

 

BIPM.RI(II)-K1.Cs-137

Key comparison reference value: the SIR reference value xR for this radionuclide is 27 613 kBq, with a standard uncertainty uequal to 47 kBq 

(see Section 4.1 of the BIPM.RI(II)-K1.Cs-137 Final report dated 2024). The value x is taken as the equivalent activity for a laboratory i.

 

The degree of equivalence of each laboratory i, with respect to the reference value is given by a pair of terms:

Di = (x- xR) and Uits expanded uncertainty (k = 2), both expressed in MBq, and

Ui = 2((1 - 2wi)ui2 + u2R)1/2, where wi is the weight of laboratory i contributing to the calculation of xR.

The degrees of equivalence are also given in relative terms by Di = (xI - xR) /xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.

 

Linking COOMET.RI(II)-K2.Cs-137 (2007) to BIPM.RI(II)-K1.Cs-137

The value xi is the equivalent activity for laboratory i participant in COOMET.RI(II)-K2.Cs-137 having been normalized to the value of the VNIIM as the linking laboratory (see section 4 of the Report dated 2013; Metrologia, 2013, 50Tech. Suppl., 06014).

 

The degree of equivalence of laboratory i participant in COOMET.RI(II)-K2.Cs-137 with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), both expressed in MBq.
The approximation Ui = 2(ui2 + uR2)1/2 is used in the following table for degrees of equivalence.

The degrees of equivalence are also given in relative terms by Di = (xI - xR) /xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in kBq/MBq.

Comparison
Comparison close
Results

BIPM.RI(II)-K1.Cs-137 and COOMET.RI(II)-K2.Cs-137

MEASURAND : Equivalent activity of 137Cs 


 

BIPM.RI(II)-K1.Cs-137

 

xi   result of measurement carried out in the SIR for the sample submitted by laboratory iLabi

ui   combined standard uncertainty of xi

  Labi xi ui Date of measurement
  kBq kBq
  NMIJ 27 720 140 2005-04-28
  VNIIM 27 450 120 2007-08-09
  IFIN-HH 27 610 220 2009-07-27
  NMISA 27 710 90 2010-08-05
  BEV 27 400 190 2011-09-27
  NRC 27 910 170 2014-03-13
  TENMAK-NUKEN 27 690 420 2018-01-11

 

 

COOMET.RI(II)-K2.Cs-137

 

xi   result of measurement carried out by laboratory i converted to the equivalent activity through the VNIIM SIR measurements (see Report dated 2013; Metrologia, 2013, 50Tech. Suppl., 06014)

ui   combined standard uncertainty of xi

  Labi xi ui Year of measurement
  kBq kBq
  BelGIM 27 220 270 2007
  SMU 27 770 310 2007