Comparison
Comparison close
Results

MEASURAND : Mass fraction of Pb in wine

Degrees of equivalence, Di and expanded uncertainty Ui (k = 2), expressed in relative terms

Comparison
Comparison close
Results

MEASURAND : Mass fraction of Pb in wine

Degrees of equivalence, Di and expanded uncertainty Ui (k = 2), expressed in ng/g, and in relative terms

Results are presented under A4 printable format in Summary Results (PDF file).

Comparison
Comparison close
CC comparison
Linked comparison
CCQM-K30.1
Metrology area, Sub-field Chemistry and Biology, Inorganics
Description Lead in wine
Time of measurements 2011 - 2012
Status Approved for equivalence
Final Reports of the comparisons
Measurand Mass fraction of Pb in wine: 2 ng/g to 25 ng/g
Transfer device Labelled bottles of 100 mL of the wine material
Comparison type Key Comparison
Consultative Committee CCQM (Consultative Committee for Amount of Substance)
Conducted by CCQM (Consultative Committee for Amount of Substance)
Comments

Results published on 15 April 2013

Lead in wine

Pilot institute CMQ
Chemical Metrology Center for Water and Foodstuffs, Foundation Chile
Chile
Contact person G. Massiff

+56 02 242 8181
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
CMQ

Chemical Metrology Center for Water and Foodstuffs, Foundation Chile, Chile, SIM

EXHM/GCSL-EIM

National Laboratory of Chemical Metrology/GCSL - Hellenic Institute of Metrology, Greece, EURAMET

HSA

Health Science Authority, Singapore, APMP

INDECOPI

Instituto Nacional de Defensa de la Competencia y de la Protección de la Propiedad Intelectual, Peru, SIM

INM

National Institute of Metrology, Romania, EURAMET

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

LGC

Laboratory of the Government Chemist, United Kingdom, EURAMET

MIRS/IJS/F-2,O-2

MIRS/Jozef Stefan Institute/Low and Medium Energy Physics F2, Environmental Sciences O2, Slovenia, EURAMET

NMIA

National Measurement Institute, Australia, Australia, APMP

NMISA

National Metrology Institute of South Africa, South Africa, AFRIMETS

UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

Comparison
Comparison close
Results

MEASURAND : Mass fraction of Pb in wine

The key comparison reference value, xR, and its standard uncertainty, uR, are calculated as explained in section 10 of the Final Report.

xR = 12.12 ng/g and uR = 0.03 ng/g

The degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms:
Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), Ui = 2(ui2 + uR2)1/2, both expressed in ng/g.
Di and Ui are also given in relative terms.

There are no paire-wise degrees of equivalence computed for this key comparison. 
Comparison
Comparison close
Results

MEASURAND : Mass fraction of Pb in wine

xi : result of measurement carried out by laboratory i
ui : standard uncertainty reported by laboratory i
ki : coverage factor reported by laboratory i
U
Labi : expanded uncertainty reported by laboratory i

INM from Romania agreed that their results will not be used in the KCRV estimation. They are not reported here.
INMETRO sent revised values on 25 September 2012: (11.85 ± 0.50) ng/g, but the KCRV calculations were carried out with the original values.