Metrology area, Sub-field Electricity and Magnetism, High voltage and current
Description Lightning impulse voltage measurement systems
Time of measurements 2016 - 2019
Status Approved
Final Reports of the comparisons
References

EURAMET.EM-S42 Registration and progress form

Measurand Lightning impulse epoch 0.84/50 µs and 1.56/50 μs.
Lightning impulse voltage peak value -100 kV, -200 kV, -300 kV, -400 kV, -500 kV, -600 kV, -700 kV and +700 kV.
Linear extension in 500 kV steps up to 2 MV.

Parameters T = [16;26] °C, RH = [40;50] %
Transfer device Reference measurement system provided by HIGHVOLT. It contains a resistive measuring divider SMR 10/700 (for up to 700kV LI), a cable and a digital recorder MIAS 200-2/2C (200MS/s, 12bit, 2 channels). Impulse voltage calibrator and chopping gap.
Comparison type Supplementary Comparison
Consultative Committee CCEM (Consultative Committee for Electricity and Magnetism)
Conducted by EURAMET (European Association of National Metrology Institutes)
RMO Internal Identifier EURAMET 1391
Comments
 
Pilot institute SP
Technical Research Institute of Sweden from 2017 Research Institutes of Sweden AB
Sweden
Contact person A-P Elg

+46 10 516 57 34
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
INTI

Instituto Nacional de Tecnologia Industrial, Argentina, SIM

LCOE

Laboratorio Central Oficial de Electrotecnica, Spain, EURAMET

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

MIKES

VTT Technical Research Centre of Finland Ltd, Centre for Metrology/Mittatekniikan keskus, Finland, EURAMET

NMIA

National Measurement Institute, Australia, Australia, APMP

NRC

National Research Council, Canada, SIM

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET