| Metrology area, Sub-field | Mass and related quantities, Fluid Flow |
| Description | LDA-based intercomparison of anemometers |
| Time of measurements | 2009 |
| Status | Approved |
| Final Reports of the comparisons | |
| Measurand | Air speed: 0.2 m/s, 0.5 m/s, 1.0 m/s, 2.0 m/s, 5.0 m/s, 10.0 m/s, 15.0 m/s, 20.0 m/s, 25.0 m/s, 30.0 m/s, 35.0 m/s and 40.0 m/s to 40 m/s |
| Transfer device | One Ultrasonic Anemometer and one Laser Doppler Anemometer (LDA) |
| Comparison type | Supplementary Comparison |
| Consultative Committee | CCM (Consultative Committee for Mass and Related Quantities) |
| Conducted by | EURAMET (European Association of National Metrology Institutes) |
| RMO Internal Identifier | EURAMET Project No 827 |
| Comments | |
| Pilot institute |
PTB
Physikalisch-Technische Bundesanstalt Germany |
| Contact person | H. Muller + 49 531 592 1310 |
| Pilot laboratory | |
|---|---|
| PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
| DTI |
Danish Technological Institute, Denmark, EURAMET |
| E+E |
E+E Elektronik, Austria, EURAMET |
| INRIM |
Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET |
| UCL |
Université Catholique de Louvain, Belgium, EURAMET |
| VSL |
VSL, Netherlands, EURAMET |