Comparison
Comparison close
Results

MEASURAND : SIR equivalent activity of 153Sm

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in MBq

Comparison
Comparison close
Results

MEASURAND : SIR equivalent activity of 153Sm

   
Lab iDiUi
 / MBq/ MBq
NIST3.17.4
PTB-2.05.4
NPL1.05.2
BNM-LNHB-2.03.6
ANSTO-8.216.5

Results are presented under A4 printable format in Summary Results (.PDF file).

Comparison
Comparison close
BIPM comparison
Linked comparison
BIPM.RI(II)-K4.Sm-153
Metrology area, Sub-field Ionizing Radiation, Section II (Measurement of Radionuclides)
Description Activity of radionuclide Sm-153
Time of measurements 2023 -
Status Protocol complete
References

BIPM.RI(II)-K4 protocol

Measurand SIRTI equivalent activity in kBq
Transfer device SIR Transfer Instrument
Comparison type Key Comparison
Consultative Committee CCRI (Consultative Committee for Ionizing Radiation)
Conducted by BIPM (Bureau International des Poids et Mesures)
Pilot institute BIPM
Bureau International des Poids et Mesures
BIPM - International Organization
Contact person Carine Michotte

+33 (0) 1 45 07 70 85
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
BIPM

Bureau International des Poids et Mesures, BIPM - International Organization, N/A

LNMRI/IRD

Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, IRD, Brazil, SIM

Comparison
Comparison close
Results

MEASURAND : SIR equivalent activity of 153Sm

Key comparison reference value:
The SIR reference value for this radionuclide is xR = 573.7 MBq, with a standard uncertainty uR = 1.2 MBq, see section 4.1 of Metrologia, 2004, 41, Tech. Suppl., 06012.

The degree of equivalence of each laboratory with respect to the reference value is given by a pair of terms:
Di = (xi - xR) and Ui, its expanded uncertainty (k = 2), both expressed in MBq. With n the number of laboratories, when each laboratory has contributed to the computation of xR.

The degree of equivalence between two laboratories is given by a pair of terms:
Dij = Di - Dj = (xi - xj) and Uij, its expanded uncertainty (k = 2), both expressed in MBq. The approximation Uij ~ 2(ui2 + uj2)1/2 is used for the computation of the pair-wise degrees of equivalence.
Comparison
Comparison close
Results

MEASURAND : SIR equivalent activity of 153Sm

xi : result of measurement carried out in the SIR for the sample submitted by laboratory i
ui
: combined standard uncertainty of xi

 Lab i xi
/ kBq
ui
/ kBq
Date of measurement
 NIST 576800 4700 98-06-23
 PTB 571700 3100 99-04-27
 NPL

574700

2900 99-07-09
 BNM-LNHB 571700 1100 03-09-11
 ANSTO

565500

8100

04-09-22