| Metrology area, Sub-field | Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer |
| Description | AC/DC transfer difference at higher voltages |
| Time of measurements | 2006 |
| Status | Approved |
| Final Reports of the comparisons | |
| Measurand | Voltage: 10 V and 100 V |
| Parameters | Frequency: 55 Hz, 1 kHz, 20 kHz and 100 kHz |
| Transfer device | Fluke 792A thermal transfer standard |
| Comparison type | Supplementary Comparison |
| Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
| Conducted by | EURAMET (European Association of National Metrology Institutes) |
| Comments | |
| Pilot institute |
PTB
Physikalisch-Technische Bundesanstalt Germany |
| Contact person | T. Funck +49 (0) 531 592 2320 |
| Pilot laboratory | |
|---|---|
| PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
| NCM |
National Centre of Metrology, now BIM (Bulgarian Institute of Metrology), Bulgaria, EURAMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).