| Metrology area, Sub-field | Electricity and Magnetism, Radio frequencies |
| Description | Comparison of electrical field strength measurements above 1 GHz |
| Time of measurements | 2007 - 2009 |
| Status | Approved |
| Final Reports of the comparisons | |
| Measurand | Electric field strength: 20 V/m |
| Parameters | Frequency: 1 GHz to 2.5 GHz (seven frequency values) |
| Transfer device | Field strength meter |
| Comparison type | Supplementary Comparison |
| Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
| Conducted by | EURAMET (European Association of National Metrology Institutes) |
| RMO Internal Identifier | EUROMET Project No 819 |
| Comments | |
| Pilot institute |
CMI
Czech Metrology Institute Czechia |
| Contact person | K. Drazil +420 266 020 173 |
| Pilot laboratory | |
|---|---|
| CMI |
Czech Metrology Institute, Czechia, EURAMET |
| INRIM |
Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET |
| LNE |
Laboratoire national de métrologie et d'essais, France, EURAMET |
| METAS |
Federal Institute of Metrology, Switzerland, EURAMET |
| NPL |
National Physical Laboratory, United Kingdom, EURAMET |
| PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
| SP |
Technical Research Institute of Sweden from 2017 Research Institutes of Sweden AB, Sweden, EURAMET |
| STUK |
Radiation and Nuclear Safety Authority, Finland, EURAMET |
| VSL |
VSL, Netherlands, EURAMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :