Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 600 kg/m3 to 620 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Graphs of equivalence

CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and SIM.M.D-S2

Density: 600 kg/m3 to 620 kg/m3
Degrees of equivalence, Di, and expanded uncertainty Ui

INDECOPI now known as INACAL

Red CCM.D-K4
Blue EUROMET.M.D-K4 (linking institutes not included)
Green SIM.M.D-K4 (linking institutes not included)
Orange SIM.M.D-S2 (linking institutes not included)

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 985 kg/m3 to 1010 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Graphs of equivalence

CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and SIM.M.D-S2

Density: 985 kg/m3 to 1010 kg/m3
Degrees of equivalence, Di, and expanded uncertainty Ui

INDECOPI now known as INACAL

Red CCM.D-K4
Blue EUROMET.M.D-K4 (linking institutes not included)
Green SIM.M.D-K4 (linking institutes not included)
Orange SIM.M.D-S2 (linking institutes not included)

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1490 kg/m3 to 1500 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Graphs of equivalence

CCM.D-K4  Density: 1490 kg/m3 to 1500 kg/m3
Degrees of equivalence, Di, and expanded uncertainty Ui

 

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1980 kg/m3 to 2000 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Graphs of equivalence

CCM.D-K4 Density: 1980 kg/m3 to 2000 kg/m3
Degrees of equivalence, Di, and expanded uncertainty Ui

 

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 600 kg/m3 to 620 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Degrees of equivalence relative to the CCM.D-K4 key comparison reference values for each artifact:

INDECOPI now known as INACAL

Red CCM.D-K4
Blue EUROMET.M.D-K4 (linking institutes not included)
Green SIM.M.D-K4 (linking institutes not included)
Orange SIM.M.D-S2 (linking institutes not included)

Results are presented under A4 printable format in Summary Results (PDF file).

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 985 kg/m3 to 1010 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Degrees of equivalence relative to the CCM.D-K4 key comparison reference values for each artifact:

 

INDECOPI now known as INACAL

Red CCM.D-K4
Blue EUROMET.M.D-K4 (linking institutes not included)
Green SIM.M.D-K4 (linking institutes not included)
Orange SIM.M.D-S2 (linking institutes not included)

Results are presented under A4 printable format in Summary Results (PDF file).

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1490 kg/m3 to 1500 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Degrees of equivalence relative to the CCM.D-K4 key comparison reference values for each artifact:

Results are presented under A4 printable format in Summary Results (PDF file).

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1980 kg/m3 to 2000 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

Degrees of equivalence relative to the CCM.D-K4 key comparison reference values for each artifact:

Results are presented under A4 printable format in Summary Results (PDF file).

Comparison
Comparison close
CC comparison
Linked comparison
CCM.D-K4
Metrology area, Sub-field Mass and related quantities, Density
Description Calibration of high resolution hydrometers
Time of measurements 2011 - 2012
Status Approved for equivalence
Final Reports of the comparisons
References

CCM.D-K4 Registration and Progress Form

CCM.D-K4 Technical Protocol

Measurand Liquid density (corrections) in the range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C
Parameters Temperature 20 °C
Pressure: 101325 Pa
Transfer device Three high resolution hydrometers (600 kg/m3, 1500 kg/m3 and 2000 kg/m3) and one alcoholometer cl. 1 (0 to 10 %vol.) for liquid density
Comparison type Key Comparison
Consultative Committee CCM (Consultative Committee for Mass and Related Quantities)
Conducted by CCM (Consultative Committee for Mass and Related Quantities)
Comments

Results published on 16 February 2016

Density of liquids

EUROMET.M.D-K4, SIM.M.D-K4 and SIM.M.D-S2 are linked to CCM.D-K4.

Pilot institute INRIM
Istituto Nazionale di Ricerca Metrologica
Italy
Contact person S. Lorefice
s.lorefice@inrim.it
+39 011 3919 929
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

CENAM

Centro Nacional de Metrologia, Mexico, SIM

GUM

Glowny Urzad Miar, Central Office of Measures, Poland, EURAMET

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

LATU

Laboratorio Tecnologico del Uruguay, Uruguay, SIM

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

MKEH

Hungarian Trade Licensing Office; now BFKH, Hungary, EURAMET

NIST

National Institute of Standards and Technology, United States, SIM

NMIA

National Measurement Institute, Australia, Australia, APMP

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 600 kg/m3 to 620 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

The key comparison CCM.D-K4 was carried out in two "petals". A reference value was calculated for each transfer instrument and petal. The method how to calculate a common key comparison reference value, xR , and associated expanded uncertainty at a 95% confidence level, UR,and the reciprocal Degrees of Equivalence is described  on pages 14 to 19 of the CCM.D-K4 Final Report and in Section 3.2.1 of the Supplement to CCM.D-K4.

 

The degree of equivalence, Di, of laboratory i with respect to the key comparison reference value is given by a par of therms: the difference Di and its expanded uncertainty (95% confidence level) Ui .

 

EUROMET.M.D-K4

The results of EUROMET.M.D-K4 were linked to CCM.M.D-K4 via the liking institutes INRiM, MKEH and the PTB who participated in both comparisons.

SIM.M.D-K4

The results of SIM.M.D-K4 were linked to CCM.M.D-K4 via the liking institute CENAM who participated in both comparisons.

SIM.M.D-S2

The results of SIM.M.D-S2 were linked to CCM.M.D-K4 via the liking institute INRiM who participated in both comparisons.

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 985 kg/m3 to 1010 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

The key comparison CCM.D-K4 was carried out in two "petals". A reference value was calculated for each transfer instrument and petal. The method how to calculate a common key comparison reference value, xR , and associated expanded uncertainty at a 95% confidence level, UR,and the reciprocal Degrees of Equivalence is described on pages 14 to 19 of the CCM.D-K4 Final Report and in Section 3.2.1 of the Supplement to CCM.D-K4.

 

The degree of equivalence, Di, of laboratory i with respect to the key comparison reference value is given by a par of therms: the difference Di and its expanded uncertainty (95% confidence level) Ui .

 

EUROMET.M.D-K4

The results of EUROMET.M.D-K4 were linked to CCM.M.D-K4 via the liking institutes INRiM, MKEH and the PTB who participated in both comparisons.

SIM.M.D-K4

The results of SIM.M.D-K4 were linked to CCM.M.D-K4 via the liking institute CENAM who participated in both comparisons.

SIM.M.D-S2

The results of SIM.M.D-S2 were linked to CCM.M.D-K4 via the liking institute INRiM who participated in both comparisons.

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1490 kg/m3 to 1500 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

 

The key comparison CCM.D-K4 was carried out in two "petals". A reference value was calculated for each transfer instrument and petal. The method how to calculate a common key comparison reference value, xR , and associated expanded uncertainty at a 95% confidence level, UR,and the reciprocal Degrees of Equivalence is described on pages 14 to 19 of the CCM.D-K4 Final Report and in Section 3.2.1 of the Supplement to CCM.D-K4.

 

The degree of equivalence, Di, of laboratory i with respect to the key comparison reference value is given by a par of therms: the difference Di and its expanded uncertainty (95% confidence level) Ui .

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1980 kg/m3 to 2000 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

 

The key comparison CCM.D-K4 was carried out in two "petals". A reference value was calculated for each transfer instrument and petal. The method how to calculate a common key comparison reference value, xR , and associated expanded uncertainty at a 95% confidence level, UR,and the reciprocal Degrees of Equivalence is described on pages 14 to 19 of the CCM.D-K4 Final Report and in Section 3.2.1 of the Supplement to CCM.D-K4.

 

The degree of equivalence, Di, of laboratory i with respect to the key comparison reference value is given by a par of therms: the difference Di and its expanded uncertainty (95% confidence level) Ui .

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 600 kg/m3 to 620 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

Measurements were carried from January 2011 to April 2012.

The participants were divided into two groups where each group used their particular set of four hydrometers. The results of the participants are given in Appendix A1 of the CCM.D-K4 Final Report.

EUROMET.M.D-K4

Laboratory individual measurement results are listed in Appendix of the EUROMET.M.D-K4 Final Report.

SIM.M.D-K4

Laboratory individual measurement results are given in the SIM.M.D-K4 Final Report.

SIM.M.D-S2

Laboratory individual measurement results are given in Section 3 of the SIM.M.D-S2 Final Report. The supplementary comparison SIM.M.D-S2 was possible to link to CCM.D-K4. To avoid confusion, it has not been renamed to carry a key comparison label.

 

Key Comparison CCM.D-K4, EUROMET.M.D-K4, SIM.M.D-K4 and Supplementary Comparison SIM.M.D-S2

MEASURAND : Density of liquids
Density: 985 kg/m3 to 1010 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

Measurements were carried from January 2011 to April 2012.

The participants were divided into two groups where each group used their particular set of four hydrometers. The results of the participants are given in Appendix A1 of the CCM.D-K4 Final Report.

EUROMET.M.D-K4

Laboratory individual measurement results are listed in Appendix of the EUROMET.M.D-K4 Final Report.

SIM.M.D-K4

Laboratory individual measurement results are given in the SIM.M.D-K4 Final Report.

SIM.M.D-S2

Laboratory individual measurement results are given in Section 3 of the SIM.M.D-S2 Final Report. The supplementary comparison SIM.M.D-S2 was possible to link to CCM.D-K4. To avoid confusion, it has not been renamed to carry a key comparison label.

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1490 kg/m3 to 1500 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

Measurements were carried from January 2011 to April 2012.

The participants were divided into two groups where each group used their particular set of four hydrometers. The results of the participants are given in Appendix A1 of the CCM.D-K4 Final Report.

Key Comparison CCM.D-K4

MEASURAND : Density of liquids
Density: 1980 kg/m3 to 2000 kg/m3

LIQUID : Nonane, Pentadecane, Tetradecane and Tridecane

CCM.D-K4

Measurements were carried from January 2011 to April 2012.

The participants were divided into two groups where each group used their particular set of four hydrometers. The results of the participants are given in Appendix A1 of the CCM.D-K4 Final Report.