CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benz[a]anthracene (BaA)

Degrees of equivalence, Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di Di / xR and its expanded uncertainty %UUi xR, both in %, are also given.

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benzo[a]pyrene (BaP)

Degrees of equivalence, Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di Di / xR and its expanded uncertainty %UUi xR, both in %, are also given.

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Naphtalene (Nap)

Degrees of equivalence, Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di Di / xR and its expanded uncertainty %UUi xR, both in %, are also given.

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benz[a]anthracene (BaA)

Degrees of equivalence, offset Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

Results are presented under A4 printable format in Summary Results.

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benzo[a]pyrene (BaP)

Degrees of equivalence, offset Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

Results are presented under A4 printable format in Summary Results.

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Naphtalene (Nap)

Degrees of equivalence, offset Di and expanded uncertainty at a 95 % level of confidence Ui, expressed in µg/g. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

Results are presented under A4 printable format in Summary Results.

Comparison
Comparison close
CC comparison
Linked comparison
CCQM-K131
Metrology area, Sub-field Chemistry and Biology, Organics
Description Mass fraction of organic calibration solution
Time of measurements 2015
Status Approved for equivalence
Final Reports of the comparisons
References

CCQM-K131 registration and progress form

Measurand Mass fraction of PAHs in acetonitrile in ng/g
Transfer device Ampouled solution available at the NIST
Comparison type Key Comparison
Consultative Committee CCQM (Consultative Committee for Amount of Substance)
Conducted by CCQM (Consultative Committee for Amount of Substance)
Comments

This study will demonstrate a laboratory’s capabilities in determining mass fraction of organic compounds with molecular mass of 100 Da to 500 Da in a multicomponent solution ranging from 100 µg/kg to 100 mg/kg.
This comparison is a repeat of CCQM-K38.

Results published on 19 December 2018

PAHs in acetonitrile

Pilot institute NIST
National Institute of Standards and Technology
United States
Contact person S. Wise

+1 301 975 3112
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
NIST

National Institute of Standards and Technology, United States, SIM

BAM

Bundesanstalt für Materialforschung und -prüfung, Germany, EURAMET

BVL

Bundesamt für Verbraucherschutz und Lebensmittelsicherheit, Germany, EURAMET

CENAM

Centro Nacional de Metrologia, Mexico, SIM

EXHM/GCSL-EIM

National Laboratory of Chemical Metrology/GCSL - Hellenic Institute of Metrology, Greece, EURAMET

GL

Government Laboratory, Hong Kong, China, APMP

HSA

Health Science Authority, Singapore, APMP

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

NIM

National Institute of Metrology, China, APMP

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NMISA

National Metrology Institute of South Africa, South Africa, AFRIMETS

UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

VNIIM

D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET

VSL

VSL, Netherlands, EURAMET

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benz[a]anthracene (BaA)

The key comparison reference value, xR, is calculated as the weighted mean of the comparison results (DerSimonian-Laird variance-weighted mean, NMISA excepted) with an associated standard uncertainty uR. The expanded uncertainty of the key comparison reference value is designated as UR.

The degree of equivalence of laboratory i relative to the key comparison reference value is given by a pair of terms, both expressed in µg/g:
Di = (xi - xR) and it expanded uncertainty at a 95 % confidence level, Ui, with Ui = 2(uLab i2 + uR2-2cov(x, xR))1/2, where cov represents the covariance. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Benzo[a]pyrene (BaP)

The key comparison reference value, xR, is calculated as the weighted mean of the comparison results (DerSimonian-Laird variance-weighted mean, BVL and NMISA excepted) with an associated standard uncertainty uR. The expanded uncertainty of the key comparison reference value is designated as UR.

The degree of equivalence of laboratory i relative to the key comparison reference value is given by a pair of terms, both expressed in µg/g:
Di = (xi - xR) and it expanded uncertainty at a 95 % confidence level, Ui, with Ui = 2(uLab i2 + uR2-2cov(x, xR))1/2, where cov represents the covariance. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

Naphtalene (Nap)

The key comparison reference value, xR, is calculated as the weighted mean of the comparison results (DerSimonian-Laird variance-weighted mean, INMETRO excepted) with an associated standard uncertainty uR. The expanded uncertainty of the key comparison reference value is designated as UR.

The degree of equivalence of laboratory i relative to the key comparison reference value is given by a pair of terms, both expressed in µg/g:
Di = (xi - xR) and it expanded uncertainty at a 95 % confidence level, Ui, with Ui = 2(uLab i2 + uR2-2cov(x, xR))1/2, where cov represents the covariance. The ratio %di = Di / xR and its expanded uncertainty %Ui = Ui / xR; both in %, are also given.

 

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi
k  : expansion coefficient
ULab i : expanded uncertainty of xi at a 95 % level of confidence (ULabi = k x ui)

Benz[a]anthracene (BaA)

 

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi
k  : expansion coefficient
ULab i : expanded uncertainty of xi at a 95 % level of confidence (ULabi = k x ui)

Benzo[a]pyrene (BaP)

 

CCQM-K131

MEASURAND : Mass fraction of PAHs in acetonitrile

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi
k  : expansion coefficient
ULab i : expanded uncertainty of xi at a 95 % level of confidence (ULabi = k x ui)

Naphtalene (Nap)