Metrology area, Sub-field | Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer |
Description | Measurement of current transformers |
Time of measurements | 2008 - 2009 |
Status | Approved |
Final Reports of the comparisons | |
Measurand | Ratio error and phase displacement at nominal ratios 4000, 2000, 1000, 500, 100, 5, 1, and 0.1; secondary current: 5 A |
Transfer device | Five current transformers |
Comparison type | Supplementary Comparison |
Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
Conducted by | EURAMET (European Association of National Metrology Institutes) |
RMO Internal Identifier | BG 2005/017-353.02.02, LOT 1 (framework of PHARE project)<BR>EURAMET Project No 1081 |
Comments | |
Pilot institute |
CMI
Czech Metrology Institute Czechia |
Contact person | R. Styblikova +420 257 288 335 |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :