| Metrology area, Sub-field | Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer |
| Description | Measurement of current transformers |
| Time of measurements | 2008 - 2009 |
| Status | Approved |
| Final Reports of the comparisons | |
| Measurand | Ratio error and phase displacement at nominal ratios 4000, 2000, 1000, 500, 100, 5, 1, and 0.1; secondary current: 5 A |
| Transfer device | Five current transformers |
| Comparison type | Supplementary Comparison |
| Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
| Conducted by | EURAMET (European Association of National Metrology Institutes) |
| RMO Internal Identifier | BG 2005/017-353.02.02, LOT 1 (framework of PHARE project)<BR>EURAMET Project No 1081 |
| Comments | |
| Pilot institute |
CMI
Czech Metrology Institute Czechia |
| Contact person | R. Styblikova +420 257 288 335 |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).