Results for: time ireland
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
7 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
General physics
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Ireland, NSAI NML (NSAI National Metrology Laboratory)
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 5.0E-13 Hz/Hz
Phase difference measurement
Averaging time : 1 day
Comparison made with NPL standard using CV method
Approved on 02 May 2006
Institute service identifier : NSAI NML/1
CMC ID : EURAMET-TF-IE-00000B3W-1
 
Frequency , Frequency : 1000 Hz to 9999 Hz
General frequency source
Absolute expanded uncertainty : 2 µHz to 1 µHz
Frequency counter
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : NSAI NML/6
CMC ID : EURAMET-TF-IE-00000B3V-1
 
Frequency , Frequency : 100 Hz to 999 Hz
General frequency source
Absolute expanded uncertainty : 6 µHz to 2 µHz
Frequency counter
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : NSAI NML/5
CMC ID : EURAMET-TF-IE-00000B3U-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 5.0E-13 Hz/Hz
Phase difference measurement
Averaging time : 1 day
Comparison made with NPL standard using CV method
Approved on 02 May 2006
Institute service identifier : NSAI NML/2
CMC ID : EURAMET-TF-IE-00000B3X-1
 
Frequency , Frequency : 0.01 MHz to 1000 MHz
General frequency source
Relative expanded uncertainty : 1.0E-10 Hz/Hz to 3.0E-11 Hz/Hz
Frequency counter
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : NSAI NML/7
CMC ID : EURAMET-TF-IE-00000B3Z-1
 
Frequency , Frequency : 10 Hz to 99 Hz
General frequency source
Absolute expanded uncertainty : 1.8E1 µHz to 6 µHz
Frequency counter
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : NSAI NML/4
CMC ID : EURAMET-TF-IE-00000B3T-1
 
Frequency , Frequency : 1 MHz
General frequency source
Relative expanded uncertainty : 1.0E-11 Hz/Hz
Frequency counter
Averaging time : 1 day
Approved on 02 May 2006
Institute service identifier : NSAI NML/3
CMC ID : EURAMET-TF-IE-00000B3Y-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.