Results for: thermometry ireland
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
42 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Ireland, NSAI NML (NSAI National Metrology Laboratory)
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 250 °C to 500 °C
IPRT
Absolute expanded uncertainty : 3.0E1 mK
Comparison
Ambient temperature : (20 ± 1) °C
Temperature-controlled salt bath
Approved on 03 November 2009
Institute service identifier : T 41
CMC ID : EURAMET-T-IE-00000DI9-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -10 °C to 100 °C
Liquid in glass thermometer
Absolute expanded uncertainty : 9 mK
Comparison
Stirred liquid bath : ice bath, water, silicone oil
Ambient temperature : (20 ± 1) °C
Approved on 03 November 2009
Institute service identifier : T 70
CMC ID : EURAMET-T-IE-00000DIC-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to -10 °C
Liquid in glass thermometer
Absolute expanded uncertainty : 2.5E1 mK
Comparison
Stirred liquid bath : acetone
Ambient temperature : (20 ± 1) °C
Approved on 03 November 2009
Institute service identifier : T 70
CMC ID : EURAMET-T-IE-00000DIB-1
 
Items for defining ITS-90 , Temperature : 273.16 K
Water triple point cell
Absolute expanded uncertainty : 0.32 mK
Direct comparison
Ambient temperature : (20 ± 1) °C
Temperature-controlled bath
Approved on 20 January 2010
Institute service identifier : T 10
CMC ID : EURAMET-T-IE-00000DIL-1
 
Items for defining ITS-90 , Temperature : 0.01 °C to 29.7646 °C
Long-stem SPRT
Absolute expanded uncertainty : 2 mK
Calibration at fixed points
Temperature-controlled bath : (20 ± 1) °C
Approved on 17 January 2013
Institute service identifier : T 33
CMC ID : EURAMET-T-IE-00000DIT-1
 
Hygrometers , Humidity : 30 °C to 75 °C
Dew-point hygrometers
Absolute expanded uncertainty : 0.2 °C
Relative humidity generator
Approved on 14 December 2018
Institute service identifier : HP-NM-06
CMC ID : EURAMET-T-IE-00000DIZ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to -10 °C
Spirit and mercury in glass - partial and total immersion thermometers
Absolute expanded uncertainty : 3.5E1 mK
Comparison in methanol bath to ITS-90 SPRT using optical imaging system. ELC values measured for partial immersion thermometers.
Calibration of partial and total immersion thermometers. Minimum graduation: 0.1 °C
Approved on 13 August 2020
Institute service identifier : TP-NM-70
CMC ID : EURAMET-T-IE-00000K4X-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -100 °C to -40 °C
Spirit in glass Thermometers - Total immersion
Absolute expanded uncertainty : 0.2 K
Comparison in methanol bath to ITS-90 SPRT using optical imaging system.
Calibration of total immersion thermometers. Minimum graduation: 0.5 °C
Approved on 13 August 2020
Institute service identifier : TP-NM-70
CMC ID : EURAMET-T-IE-00000K4W-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 200 °C to 250 °C
Sensor with display
Absolute expanded uncertainty : 1.0E1 mK
Comparison
Stirred liquid bath : silicone oil
Ambient temperature : (20 ± 1) °C
Approved on 03 November 2009
Institute service identifier : T 22
CMC ID : EURAMET-T-IE-00000DIJ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 200 °C
IPRT
Absolute expanded uncertainty : 7 mK
Comparison
Ambient temperature : (20 ± 1) °C
Temperature-controlled oil bath
Approved on 03 November 2009
Institute service identifier : T 41
CMC ID : EURAMET-T-IE-00000DI7-1
 
Items for defining ITS-90 , Temperature : -38.8344 °C to 29.7646 °C
Long-stem SPRT
Absolute expanded uncertainty : 2 mK
Calibration at fixed points
Temperature-controlled bath : (20 ± 1) °C
Approved on 17 January 2013
Institute service identifier : T 33
CMC ID : EURAMET-T-IE-00000DIR-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Sensor with display
Absolute expanded uncertainty : 4 mK
Comparison
Stirred liquid bath : ice bath
Approved on 03 November 2009
Institute service identifier : T 22
CMC ID : EURAMET-T-IE-00000DIG-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -75 °C to 0 °C
IPRT
Absolute expanded uncertainty : 5 mK
Comparison
Ambient temperature : (20 ± 1) °C
Temperature-controlled acetone bath
Approved on 03 November 2009
Institute service identifier : T 41
CMC ID : EURAMET-T-IE-00000DI4-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -100 °C to 0 °C
IPRT
Absolute expanded uncertainty : 6 mK
Calibration by comparison to ITS-90 SPRT in methanol bath.
ITS-90
Approved on 02 December 2020
Institute service identifier : TP-NM-90
CMC ID : EURAMET-T-IE-00000K4V-1
 
Items for disseminating ITS-90 and PLTS 2000 , Air Temperature : -40 °C to 100 °C
Air temperature sensor
Absolute expanded uncertainty : 0.19 °C to 0.36 °C
{"row_1":{"col_1":"Minimum temperature / °C","col_2":"Maximum temperature / °C","col_3":"CMC as expanded uncertainty (<em>k</em>&nbsp;= 2) / °C"},"row_2":{"col_1":"-40","col_2":"-10","col_3":"0.20"},"row_3":{"col_1":"-10","col_2":"+60","col_3":"0.19"},"row_4":{"col_1":"+60","col_2":"+100","col_3":"0.36"}}
Calibration by comparison to reference PRTs
Approved on 24 January 2022
Institute service identifier : HP-NM-01, HP-NM-05
CMC ID : EURAMET-T-IE-00000LR5-1
 
Hygrometers , Humidity : 10 %rh to 95 %rh
Relative humidity sensors
Absolute expanded uncertainty : 0.6 %rh to 2 %rh
Comparison in a climatic chamber
Air temperature : 15 °C to 60 °C
Approved on 14 December 2018
Institute service identifier : HP-NM-05
CMC ID : EURAMET-T-IE-00000DIW-1
 
Items for defining ITS-90 , Temperature : 419.527 °C
Cell for contact thermometry
Absolute expanded uncertainty : 2.9 mK
Freezing point of zinc
Ambient temperature : (20 ± 1) °C
Temperature-controlled furnace
Approved on 17 January 2013
Institute service identifier : T 45
CMC ID : EURAMET-T-IE-00000DI3-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 100 °C to 200 °C
Liquid in glass thermometer
Absolute expanded uncertainty : 2.0E1 mK
Comparison
Stirred liquid bath : silicone oil
Ambient temperature : (20 ± 1) °C
Approved on 03 November 2009
Institute service identifier : T 70
CMC ID : EURAMET-T-IE-00000DID-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 250 °C to 500 °C
Sensor with display
Absolute expanded uncertainty : 3.0E1 mK
Comparison
Stirred liquid bath : salt
Ambient temperature : (20 ± 1) °C
Approved on 03 November 2009
Institute service identifier : T 22
CMC ID : EURAMET-T-IE-00000DIK-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 80 °C
IPRT
Absolute expanded uncertainty : 5 mK
Comparison
Ambient temperature : (20 ± 1) °C
Temperature-controlled water bath
Approved on 03 November 2009
Institute service identifier : T 41
CMC ID : EURAMET-T-IE-00000DI6-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.