Results for: ijs o-2 iron
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Hong Kong, China, GL (Government Laboratory)
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in % |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
pure material |
high polarity organic compounds (pKow > and = -2) with Mwt between 75-500 g/mol |
70 to 100 |
0.5 to 2 |
|
|
-
Mechanism for measurement service delivery :
CRM and Calibration service
-
Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs. Reference Material GLHK-01-02 (Estradiol) is covered by this CMC
-
Approved on
15 June 2021
-
Institute service identifier : GLHK110
-
CMC ID :
APMP-QM-HK-00000LZV-1
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in % |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
pure material |
low polarity organic compounds (pKow < -2) with Mwt 501 - 1000 g/mol |
70 to 100 |
1.5 to 2.5 |
|
|
-
Mechanism for measurement service delivery :
CRM and Calibration service
-
Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs.
-
Approved on
15 June 2021
-
Institute service identifier : GLHK112
-
CMC ID :
APMP-QM-HK-00000LZY-1
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in % |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
pure material |
low polarity organic compounds (pKow < -2) with Mwt between 75-500 g/mol |
70 to 100 |
0.5 to 2 |
|
|
-
Mechanism for measurement service delivery :
CRM and Calibration service
-
Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs covered by this CMC. Reference Material GLHK-01-01 (Melamine) is covered by this CMC
-
Approved on
15 June 2021
-
Institute service identifier : GLHK111
-
CMC ID :
APMP-QM-HK-00000LZW-1
Slovenia, MIRS/IJS/F-2,O-2 (MIRS/Jozef Stefan Institute/Low and Medium Energy Physics F2, Environmental Sciences O2)
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/kg |
Absolute expanded uncertainty in % |
Mass fraction in |
Absolute expanded uncertainty in |
seafood |
iron |
160 to 500 |
4 to 8 |
|
|
-
Mechanism for measurement service delivery :
Reference measurement
-
Approved on
08 July 2015
-
Institute service identifier : O-2ICP-MSe
-
CMC ID :
EURAMET-QM-SI-000001A2-1
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/g |
Absolute expanded uncertainty in % |
Mass fraction in |
Absolute expanded uncertainty in |
soil |
iron |
10 to 50 |
8 to 6 |
|
|
-
Mechanism for measurement service delivery :
Reference measurement
-
Approved on
28 June 2018
-
Institute service identifier : O-2k0-INAAf
-
CMC ID :
EURAMET-QM-SI-000001US-1
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/kg |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
milk powder |
iron |
2 to 60 |
1.2E1 to 8 |
|
|
-
Mechanism for measurement service delivery :
Reference measurement service
-
Approved on
30 June 2022
-
Institute service identifier : O-2ICP-MSj
-
CMC ID :
EURAMET-QM-SI-00000NRZ-1
United Kingdom, LGC (Laboratory of the Government Chemist)
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in % |
Absolute expanded uncertainty in % |
Mass fraction in |
|
pure material |
high polarity organic compounds with Mwt below 500 |
70 to 100 |
0.4 to 1 |
|
|
-
Mechanism for measurement service delivery :
Calibration service
-
(MW <500) and high polarity ( pKOW > -2) for which related structure impurities can be quantified by high performance liquid chromatography. Compounds existing as a salt are certified as the mass fraction of the free base/free acid. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt.
-
Approved on
17 May 2020
-
Institute service identifier : Org-060
-
CMC ID :
EURAMET-QM-GB-000002AK-2
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in % |
Absolute expanded uncertainty in % |
Mass fraction in |
|
pure material |
low polarity organic compounds with Mwt below 500 |
70 to 100 |
0.3 to 1 |
|
|
-
Mechanism for measurement service delivery :
Calibration service
-
(MW <500) and low polarity ( pKOW < -2) for which related structure impurities can be quantified by high performance liquid or gas chromatography. Compounds existing as a salt are certified as the mass fraction of the free base/free acid. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt.
-
Approved on
17 May 2020
-
Institute service identifier : Org-061
-
CMC ID :
EURAMET-QM-GB-00000LB1-1