Results for: ijs o-2 iron
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
8 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Hong Kong, China, GL (Government Laboratory)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
pure material high polarity organic compounds (pKow > and = -2) with Mwt between 75-500 g/mol 70 to 100 0.5 to 2
  • Mechanism for measurement service delivery : CRM and Calibration service
  • Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs. Reference Material GLHK-01-02 (Estradiol) is covered by this CMC
  • Approved on 15 June 2021
  • Institute service identifier : GLHK110
  • CMC ID : APMP-QM-HK-00000LZV-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
pure material low polarity organic compounds (pKow < -2) with Mwt 501 - 1000 g/mol 70 to 100 1.5 to 2.5
  • Mechanism for measurement service delivery : CRM and Calibration service
  •  Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs. 
  • Approved on 15 June 2021
  • Institute service identifier : GLHK112
  • CMC ID : APMP-QM-HK-00000LZY-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
pure material low polarity organic compounds (pKow < -2) with Mwt between 75-500 g/mol 70 to 100 0.5 to 2
  • Mechanism for measurement service delivery : CRM and Calibration service
  • Compounds existing as a salt are certified as the mass fraction of the free base/free acid to ensure traceability of the certified values. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt. Refer to GL website for information of current CRMs covered by this CMC. Reference Material GLHK-01-01 (Melamine) is covered by this CMC
  • Approved on 15 June 2021
  • Institute service identifier : GLHK111
  • CMC ID : APMP-QM-HK-00000LZW-1
     
Slovenia, MIRS/IJS/F-2,O-2 (MIRS/Jozef Stefan Institute/Low and Medium Energy Physics F2, Environmental Sciences O2)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
seafood iron 160 to 500 4 to 8
  • Mechanism for measurement service delivery : Reference measurement
  • Approved on 08 July 2015
  • Institute service identifier : O-2ICP-MSe
  • CMC ID : EURAMET-QM-SI-000001A2-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/g Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
soil iron 10 to 50 8 to 6
  • Mechanism for measurement service delivery : Reference measurement
  • Approved on 28 June 2018
  • Institute service identifier : O-2k0-INAAf
  • CMC ID : EURAMET-QM-SI-000001US-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
milk powder iron 2 to 60 1.2E1 to 8
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 30 June 2022
  • Institute service identifier : O-2ICP-MSj
  • CMC ID : EURAMET-QM-SI-00000NRZ-1
     
United Kingdom, LGC (Laboratory of the Government Chemist)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Absolute expanded uncertainty in % Mass fraction in
pure material high polarity organic compounds with Mwt below 500 70 to 100 0.4 to 1
  • Mechanism for measurement service delivery : Calibration service
  • (MW <500) and high polarity ( pKOW > -2) for which related structure impurities can be quantified by high performance liquid chromatography. Compounds existing as a salt are certified as the mass fraction of the free base/free acid. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt.
  • Approved on 17 May 2020
  • Institute service identifier : Org-060
  • CMC ID : EURAMET-QM-GB-000002AK-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Absolute expanded uncertainty in % Mass fraction in
pure material low polarity organic compounds with Mwt below 500 70 to 100 0.3 to 1
  • Mechanism for measurement service delivery : Calibration service
  • (MW <500) and low polarity ( pKOW < -2) for which related structure impurities can be quantified by high performance liquid or gas chromatography. Compounds existing as a salt are certified as the mass fraction of the free base/free acid. Although the measurement capability range extends down to 70% mass fraction, the main impurity is the stoichiometric counter ion of the salt.
  • Approved on 17 May 2020
  • Institute service identifier : Org-061
  • CMC ID : EURAMET-QM-GB-00000LB1-1
     

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.