Results for: georgia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
65 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)
High voltage and current , AC high current, current transformers: ratio error : 1.00E-3 to 0.01
Current transformer
Absolute expanded uncertainty : 3.2E-5 to 2.3E-4
Comparison with a reference current transformer
Primary current : 1 A to 2000 A
Frequency : 50 Hz
Approved on 09 March 2015
Institute service identifier : GEOSTM/EM-27
CMC ID : EURAMET-EM-GE-00000OL2-1
 
High voltage and current , AC high voltage transformer: phase displacement : 0 rad to 0.1 rad
Voltage transformer
Absolute expanded uncertainty : 5.0E-5 rad to 2.0E-2 rad
Current comparison with current comparator and two capacitors
Primary voltage : 500 V to 70 kV
Frequency : 50 Hz
Approved on 09 March 2015
Institute service identifier : GEOSTM/EM-26
CMC ID : EURAMET-EM-GE-00000OL1-1
 
DC resistance , DC resistance standards and sources: low values : 1 Ω
Resistance standard
Absolute expanded uncertainty : 2.0E-5 Ω
20E-06R with resistance R
The uncertainty is expressed in Ω
Substitution with a DMM
Temperature : (23 ± 3) °C
Approved on 19 May 2015
Institute service identifier : GEOSTM/EM-13
CMC ID : EURAMET-EM-GE-00000OKS-1
 
Mass , Mass : 0.1 g to 1 g
Mass standard
Absolute expanded uncertainty : 5 µg to 1.0E1 µg
Comparison in air
Temperature : 18 °C to 23 °C
Relative humidity : 40 % to 60 %
Approved on 31 March 2015
Institute service identifier : GEOSTM/M-2
CMC ID : EURAMET-M-GE-00000OLC-1
 
Mass , Mass : 1 mg to 100 mg
Mass standard
Absolute expanded uncertainty : 3 µg to 5 µg
Comparison in air
Temperature : 18 °C to 23 °C
Relative humidity : 40 % to 60 %
Approved on 31 March 2015
Institute service identifier : GEOSTM/M-1
CMC ID : EURAMET-M-GE-00000OLB-1
 
Items for defining ITS-90 , Temperature : 0.01 °C to 231.928 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.3 mK to 2 mK
Calibration at fixed points
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-7
CMC ID : EURAMET-T-GE-00000OLP-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Mercury-in-glass total immersion 0.1 °C graduation
Absolute expanded uncertainty : 5.0E-2 °C
Ice melting point
Thermostat : ice bath
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-13
CMC ID : EURAMET-T-GE-00000OM4-1
 
Items for defining ITS-90 , Temperature : 0.01 °C
Long-stem Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.3 mK
Water triple point
Thermostat : ice bath
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-4
CMC ID : EURAMET-T-GE-00000OLM-1
 
Mass , Mass : 0.1 kg to 1 kg
Mass standard
Absolute expanded uncertainty : 5.0E1 µg to 5.0E2 µg
Comparison in air
Temperature : 18 °C to 23 °C
Relative humidity : 40 % to 60 %
Approved on 31 March 2015
Institute service identifier : GEOSTM/M-5
CMC ID : EURAMET-M-GE-00000OLF-1
 
Hygrometers , Humidity : 30 %rh to 90 %rh
Hygrometer with impedance capacitive or resistive convertor
Absolute expanded uncertainty : 2 %rh
Comparison method
23°C : in Climatic chamber
Approved on 05 July 2021
Institute service identifier : H-3
CMC ID : EURAMET-T-GE-00000OLK-1
 
Pressure , Gauge pressure : 0 Pa to 2.00E6 Pa
Pressure gauge
Absolute expanded uncertainty : 6.3E2 Pa
Gas medium
Approved on 29 May 2020
Institute service identifier : MP-2
CMC ID : EURAMET-M-GE-00000OLH-1
 
AC power , AC power and energy: three phase, active power : 0.03 W to 8.64E4 W
Power meter, power converter, wattmeter, power comparator, power calibrator
Relative expanded uncertainty : 1.5E2 µW/VA to 3.0E2 µW/VA
{"row_1": {"col_1":"Current", "col_2":"Power factor", "col_3":"60 V to 480 V"}, "row_2": {"col_1":"5 mA to 50 mA", "col_2":"1 ", "col_3":"200"}, "row_3": {"col_1":"-", "col_2":"0.5 i and 0.5 c", "col_3":"300"}, "row_4": {"col_1":">50 mA to10 A", "col_2":"1", "col_3":"150"}, "row_5": {"col_1":"-", "col_2":"0.5 i and 0.5 c", "col_3":"300"}, "row_6": {"col_1":">10 A to 120 A", "col_2":"1 ", "col_3":"200"}, "row_7": {"col_1":"-", "col_2":"0.5 i and 0.5 c", "col_3":"300"}}
The expanded uncertainty given in this table are expressed in µW/VA.
Comparison
Frequency : 50 Hz to 60 Hz
Voltage : 60 V to 480 V
Current : 0.005 A to 120 A
Power factor : 0.5 i to 1 to 0.5 c
Approved on 28 March 2020
Institute service identifier : EM-37
CMC ID : EURAMET-EM-GE-00000OKQ-1
 
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 1.00E-3 V to 1100 V
DC voltage calibrator
Absolute expanded uncertainty : 3.0E-6 V to 7.2E-3 V
{"row_1": {"col_1":"", "col_2":"Expanded uncertainty / (V)"}, "row_2": {"col_1":"0.01 V to 0.2 V", "col_2":"2E-06<em>U<\/em> + 3E-06"}, "row_3": {"col_1":"&gt; 0.2 V to 2 V", "col_2":"3E-06<em>U<\/em> + 2E-06"}, "row_4": {"col_1":"&gt; 2 V to 20 V", "col_2":"3.5E-06<em>U<\/em> + 6E-06"}, "row_5": {"col_1":"&gt; 20 V to 200 V", "col_2":"6E-06<em>U<\/em> + 50E-06"}, "row_6": {"col_1":"&gt; 200 V to 1000 V", "col_2":"6E-06<em>U<\/em> + 600E-06"}, "row_7": {"col_1":"0.02 V to 0.22 V ", "col_2":"2E-06<em>U<\/em> + 3E-06"}, "row_8": {"col_1":"&gt; 0.22 V to 2.2 V", "col_2":"3E-06<em>U<\/em> + 2E-06"}, "row_9": {"col_1":"&gt; 2.2 V to 22 V", "col_2":"3.5E-06<em>U<\/em> + 6E-06"}, "row_10": {"col_1":"&gt; 22 V to 220 V", "col_2":"6E-06<em>U<\/em> + 50E-06"}, "row_11": {"col_1":"&gt; 220 V to 1100 V", "col_2":"6E-06<em>U<\/em> + 600E-06"}}
2E-06U + 3E-06) to (6E-06U + 600E-06 with voltage U
The uncertainty is expressed in V
Direct measurement
Temperature : (23 ± 3) °C
Approved on 19 May 2015
Institute service identifier : GEOSTM/EM-8 to EM-12
CMC ID : EURAMET-EM-GE-00000OL0-1
 
High voltage and current , AC high voltage transformer: ratio error : 0 to 0.01
Voltage transformer
Absolute expanded uncertainty : 1.0E-4 to 2.0E-3
Current comparison with current comparator and two capacitors
Primary voltage : 500 V to 70 kV
Frequency : 50 Hz
Approved on 09 March 2015
Institute service identifier : GEOSTM/EM-25
CMC ID : EURAMET-EM-GE-00000OL4-1
 
Hygrometers , Humidity : 30 %rh to 90 %rh
Mechanical hygrometer
Absolute expanded uncertainty : 3 %rh
Comparison method
23°C : in Climatic chamber
Approved on 05 July 2021
Institute service identifier : H-1
CMC ID : EURAMET-T-GE-00000OLI-1
 
Pressure , Absolute pressure : 1.00E5 Pa to 7.00E6 Pa
Pressure gauge
Absolute expanded uncertainty : 1.8E3 Pa
Gas medium
Approved on 15 August 2020
Institute service identifier : MP-1
CMC ID : EURAMET-M-GE-00000OLG-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 200 °C to 420 °C
Mercury-in-glass thermometer total immersion; 0.01 °C
Absolute expanded uncertainty : 2.5E-2 K
Comparison method
Thermostat : Salt
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-19
CMC ID : EURAMET-T-GE-00000OMA-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 200 °C
Mercury-in-glass thermometer total immersion; 0.01 °C
Absolute expanded uncertainty : 2.0E-2 K
Comparison method
Thermostat : Oil
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-18
CMC ID : EURAMET-T-GE-00000OM9-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 200 °C
Digital thermometer IPRT
Absolute expanded uncertainty : 0.2 K to 1.2 K
Comparison method
Thermostat : Oil
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-30
CMC ID : EURAMET-T-GE-00000OLW-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 419.527 °C
Zinc cell
Absolute expanded uncertainty : 2.7 mK
Direct comparison
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : GEOSTM/T-3
CMC ID : EURAMET-T-GE-00000OLZ-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.