Results for: bvl
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Germany, BVL (Bundesamt für Verbraucherschutz und Lebensmittelsicherheit)
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| botanical matrix |
alpha-HCH |
50 to 200 |
2.0E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
16 June 2021
-
Institute service identifier : CLPE_007-2
-
CMC ID :
EURAMET-QM-DE-00000M6G-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| botanical matrix |
Benzo(a)anthracene |
10 to 100 |
7 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
11 April 2021
-
Institute service identifier : PAH_0061
-
CMC ID :
EURAMET-QM-DE-00000M6C-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| botanical matrix |
benzo(a)pyrene |
10 to 100 |
1.8E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
11 April 2021
-
Institute service identifier : PAH_0062
-
CMC ID :
EURAMET-QM-DE-00000M6D-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| Vegetable edible oils |
benzo(a)pyrene |
1 to 20 |
1.7E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
16 June 2021
-
Institute service identifier : PAH_001
-
CMC ID :
EURAMET-QM-DE-00000M6B-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| animal tissues |
chloramphenicol |
0.1 to 10 |
2.2E1 to 1.9E1 |
|
|
-
Mechanism for measurement service delivery :
provision of reference values for proficiency test schemes organised for the official food control laboratories working according to Regulation (EU) 2017/625
-
Approved on
17 June 2026
-
Institute service identifier : CAP_014
-
CMC ID :
EURAMET-QM-DE-00000RB5-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Absolute expanded uncertainty in % |
Mass fraction in |
Absolute expanded uncertainty in |
| tissue |
clenbuterol |
0.3 to 15 |
1.3E1 to 1.8E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
30 June 2017
-
Institute service identifier : BETA_012
-
CMC ID :
EURAMET-QM-DE-000001QS-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| botanical matrix |
gamma-HCH |
50 to 200 |
2.3E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
16 June 2021
-
Institute service identifier : CLPE_007
-
CMC ID :
EURAMET-QM-DE-00000M6F-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| animal tissues |
metronidazole |
0.1 to 50 |
1.5E1 to 1.4E1 |
|
|
-
Mechanism for measurement service delivery :
provision of reference values for proficiency test schemes organised for the official food control laboratories working according to Regulation (EU) 2017/625
-
Approved on
17 June 2026
-
Institute service identifier : NIIM_009
-
CMC ID :
EURAMET-QM-DE-00000RB4-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
| Mass fraction in ng/g |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
| animal tissue |
sulfadiazine |
100 to 1000 |
2.0E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
16 June 2021
-
Institute service identifier : MAB_005
-
CMC ID :
EURAMET-QM-DE-00000M6E-1
Poland, GUM (Glowny Urzad Miar, Central Office of Measures)
DC resistance ,
DC resistance standards and sources: high values
:
2.00E6 Ω to 1.00E14 Ω
Fixed resistor, resistor box
Relative expanded uncertainty
:
0.3 µΩ/Ω to 4.7E3 µΩ/Ω
Uncertainty table
{"row_1":{"col_1":"","col_2":"Current comparator bridge, BVD, resistance ratio bridge","col_3":"Direct comparison with teraohmmeter"},"row_2":{"col_1":"1E+07 Ω","col_2":"0.3","col_3":"-"},"row_3":{"col_1":"2E+06 Ω to 2E+07 Ω ","col_2":"-","col_3":"180"},"row_4":{"col_1":" 2E+07 Ω to 2E+08 Ω ","col_2":"-","col_3":"100"},"row_5":{"col_1":"1E+08 Ω","col_2":"0.5","col_3":"-"},"row_6":{"col_1":"2E+08 Ω to 2E+09 Ω","col_2":"-","col_3":"180"},"row_7":{"col_1":"1E+09 Ω","col_2":"3","col_3":"-"},"row_8":{"col_1":"2E+09 Ω to 2E+10 Ω","col_2":"-","col_3":"470"},"row_9":{"col_1":"1E+10 Ω","col_2":"110","col_3":"-"},"row_10":{"col_1":"2E+10 Ω to 2E+11 Ω","col_2":"-","col_3":"690"},"row_11":{"col_1":"1E+11 Ω","col_2":"300","col_3":"-"},"row_12":{"col_1":"2E+11 Ω to 2E+12 Ω","col_2":"-","col_3":"1200"},"row_13":{"col_1":"1E+12 Ω","col_2":"670","col_3":"-"},"row_14":{"col_1":"2E+12 Ω to 2E+13 Ω","col_2":"-","col_3":"2900"},"row_15":{"col_1":"2E+13 Ω to 2E+14 Ω","col_2":"-","col_3":"4700"}}
Current comparator bridge, BVD, resistance ratio bridge, direct comparison with teraohmmeter
Approved on 07 April 2016
Institute service identifier : GUM/7z
CMC ID :
EURAMET-EM-PL-00000EQK-1