Results for: United Kingdom "TUVNEL"
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
United Kingdom, TUVNEL (TUVNEL)
Fluid flow ,
Liquid flowing quantity: mass or volume
:
2.00E-3 L/min to 2.4 L/min
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
5.0E-2 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : kerosine, gas-oil, velocite, water, any safe liquid
Viscosity : up to 30 cSt
Temperature : ambient
Pressure : 0 MPa to 0.5 MPa
Approved on 15 October 2013
Institute service identifier : UK1
KCDB ID :
EURAMET-M-GB-00000FW3-2
Fluid flow ,
Liquid flowing quantity: mass and volume
:
0.1 L/s to 350 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
0.15 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : water
Temperature : 15 °C to 35 °C
Pressure : 0 MPa to 1 MPa (0.1 l/s to 200 l/s)
Pressure : 0 MPa to 0.5 MPa (200 l/s to 400 l/s)
Approved on 15 October 2013
Institute service identifier : UK7
KCDB ID :
EURAMET-M-GB-00000FW9-2
Fluid flow ,
Liquid flowing quantity: mass or volume
:
0.04 L/s to 100 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
5.0E-2 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : heavy oil
Viscosity : 30 cSt and 500 cSt
Temperature : 5 °C to 50 °C
Pressure : 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Institute service identifier : UK3
KCDB ID :
EURAMET-M-GB-00000FW5-1
Fluid flow ,
Liquid flowing quantity: mass and volume
:
0.1 L/s to 200 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
0.1 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : water
Temperature : 15 °C to 35 °C
Pressure : 0 MPa to 1 MPa
Approved on 15 October 2013
Institute service identifier : UK6
KCDB ID :
EURAMET-M-GB-00000FW8-2
Fluid flow ,
Liquid flowing quantity: mass or volume
:
0.04 L/s to 200 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
8.0E-2 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : kerosine, gas-oil, mineral oils
Viscosity : 2.2 cSt to 30 cSt
Temperature : 5 °C to 50 °C
Pressure : 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Institute service identifier : UK4
KCDB ID :
EURAMET-M-GB-00000FW6-1
Fluid flow ,
Liquid flowing quantity: mass or volume
:
0.04 L/s to 150 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
0.25 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : heavy oil
Viscosity : 30 cSt to 500 cSt
Temperature : 5 °C to 50 °C
Pressure : 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Institute service identifier : UK5
KCDB ID :
EURAMET-M-GB-00000FW7-1
Fluid flow ,
Liquid flowing quantity: mass or volume
:
0.04 L/s to 100 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
3.0E-2 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : kerosine, gas-oil, mineral oils
Viscosity : 2.2 cSt to 30 cSt
Temperature : 5 °C to 50 °C
Pressure : 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Institute service identifier : UK2
KCDB ID :
EURAMET-M-GB-00000FW4-1
Fluid flow ,
Volume liquidhydrocarbon flowrate
:
0.5 L/s to 100 L/s
Any flow measurement instrument or flow device
Relative expanded uncertainty
:
8.0E-2 %
Pulsed, electrical, digital and optical outputs; various methods
Fluid : Mineral oil
Viscosity : 1.5 cP to 10 cP
Temperature : 20 °C to 80 °C
Pressure : 0.5 MPa to 9.4 MPa
Approved on 17 November 2017
Institute service identifier : UK8
KCDB ID :
EURAMET-M-GB-00000FWA-2