Results for: Ukraine "SE
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
129 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Ukraine, SE "Ivano-Frankivskstandard metrologia" (State Enterprise "Ivano-Frankivskstandard metrologia")
Fluid flow , Flowrate volume (low pressure gas) : 1 m3/h to 7800 m3/h
Flow meter, gas meter, critical nozzles
Relative expanded uncertainty : 0.12 %
Pulsed or electrical outputs, reference meters comparison
Fluid : air
Temperature : ambient
Pressure : ambient
Pipe size : DN32 to DN400
Approved on 08 November 2022
Institute service identifier : UA4
CMC ID : EURAMET-M-UA-00000ORV-1
 
Fluid flow , Gas flowrate volume : 4 m3/h to 200 m3/h
Gas-flow meter
Relative expanded uncertainty : 0.1 %
Pulsed or electrical outputs
Fluid : dry air
Temperature : 20 ºC ± 2 ºC
Pressure : 84 kPa to 106.7 kPa
Pipe size : DN 15 - DN 150
Approved on 05 October 2009
Institute service identifier : UA1
CMC ID : EURAMET-M-UA-00000ORS-1
 
Fluid flow , Gas flowrate volume : 0.016 m3/h to 16 m3/h
Gas-flow meter
Relative expanded uncertainty : 0.15 %
Pulsed or electrical outputs
Fluid : dry air
Temperature : 20 ºC ± 2 ºC
Pressure : 84 kPa to 106.7 kPa
Pipe size : DN 15 - DN 40
Approved on 05 October 2009
Institute service identifier : UA2
CMC ID : EURAMET-M-UA-00000ORT-1
 
Fluid flow , Gas flowrate volume : 20 m3/h to 1600 m3/h
Gas-flow meter
Relative expanded uncertainty : 0.16 %
Pulsed or electrical outputs
Fluid : dry air
Temperature : 20 ºC ± 2 ºC
Pressure : 84 kPa to 106.7 kPa
Pipe size : DN 80 - DN 200
Approved on 05 October 2009
Institute service identifier : UA3
CMC ID : EURAMET-M-UA-00000ORU-1
 
Ukraine, SE "NDI Systema" (State Enterprise "Scientific-Research Institute for Metrology of Measurement and Control Systems")
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 9.0E-2 dB
IEC 61094-2:1992
Frequency : 31.5 Hz to 40 Hz
Approved on 09 January 2008
CMC ID : EURAMET-AUV-UA-00000OV5-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 50 Hz to 63 Hz
Approved on 09 January 2008
CMC ID : EURAMET-AUV-UA-00000OV6-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 7.0E-2 dB
IEC 61094-2:1992
Frequency : 8 kHz
Approved on 09 January 2008
CMC ID : EURAMET-AUV-UA-00000OV9-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type WS2
Absolute expanded uncertainty : 0.25 dB
IEC 61094-5:2001 (on 250 Hz), and IEC 61094-6:2004 (electrostatic actuator frequency response)
Frequency : 630 Hz to 2.5 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVH-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type WS2
Absolute expanded uncertainty : 0.65 dB
IEC 61094-5:2001 (on 250 Hz), and IEC 61094-6:2004 (electrostatic actuator frequency response)
Frequency : 12.5 kHz to 20 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVJ-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type WS2
Absolute expanded uncertainty : 0.36 dB
IEC 61094-5:2001 (on 250 Hz), and IEC 61094-6:2004 (electrostatic actuator frequency response)
Frequency : 3.15 kHz to 10 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVI-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 4.0E-2 dB
IEC 61094-2:2009
Frequency : 20 Hz to < 31.5 Hz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVQ-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 7.0E-2 dB
IEC 61094-2:2009
Frequency : 5 Hz to < 8 Hz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVN-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 10 kHz
Approved on 09 January 2008
CMC ID : EURAMET-AUV-UA-00000OVA-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type WS1
Absolute expanded uncertainty : 0.6 dB
IEC 61094-5:2001 (on 250 Hz), and IEC 61094-6:2004 (electrostatic actuator frequency response)
Frequency : 2 kHz to 10 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVG-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 5.0E-2 dB
IEC 61094-2:2009
Frequency : 12.5 Hz to < 20 Hz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVP-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 6.0E-2 dB
IEC 61094-2:1992
Frequency : 500 Hz to 6.3 kHz
Approved on 09 January 2008
CMC ID : EURAMET-AUV-UA-00000OV8-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 7.0E-2 dB
IEC 61094-2:2009
Frequency : > 4 kHz to 5 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVV-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 0.1 dB
IEC 61094-2:2009
Frequency : > 8 kHz to 10 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OV4-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 9.0E-2 dB
IEC 61094-2:2009
Frequency : 2.5 Hz to < 3.15 Hz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVL-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 6.0E-2 dB
IEC 61094-2:2009
Frequency : > 3.15 kHz to 4 kHz
Approved on 30 August 2017
CMC ID : EURAMET-AUV-UA-00000OVU-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.