Results for: Switzerland
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
424 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Switzerland, IRA (Institut Universitaire de Radiophysique Appliquée)
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4.00E4 Bq/g to 3.00E7 Bq/g
Relative expanded uncertainty 0.4 %
Secondary standard ionization chamber, balance
Cs-137, no further specifications
Reference standard : 4πβγ efficiency tracing, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2016
CMC ID : EURAMET-RI-CH-00000GSC-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 2.00E4 Bq/g to 1.50E7 Bq/g
Relative expanded uncertainty 0.8 %
Secondary standard ionization chamber, balance
F-18, no further specifications
Reference standard : 4πγ NaI counting, LS counting (efficiency tracing), standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2001
CMC ID : EURAMET-RI-CH-00000GSL-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4.00E4 Bq/g to 3.00E7 Bq/g
Relative expanded uncertainty 1 %
Secondary standard ionization chamber, balance
Se-75, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2006
CMC ID : EURAMET-RI-CH-00000GSQ-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E5 Bq/g to 7.00E7 Bq/g
Relative expanded uncertainty 0.6 %
Secondary standard ionization chamber, balance
Ce-139, no further specifications
Reference standard : 4π(PC)γ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2017
CMC ID : EURAMET-RI-CH-00000GSD-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E4 Bq/g to 7.00E6 Bq/g
Relative expanded uncertainty 0.3 %
Secondary standard ionization chamber, balance
Co-60, no further specifications
Reference standard : 4πβγ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2005
CMC ID : EURAMET-RI-CH-00000GSP-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E5 Bq/g to 7.00E7 Bq/g
Relative expanded uncertainty 1.4 %
Secondary standard ionization chamber, balance
Tc-99m, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2009
CMC ID : EURAMET-RI-CH-00000GST-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4.00E4 Bq/g to 2.50E7 Bq/g
Relative expanded uncertainty 0.5 %
Secondary standard ionization chamber, balance
Yb-169, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2019
CMC ID : EURAMET-RI-CH-00000GSF-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 3.00E4 Bq/g to 2.00E7 Bq/g
Relative expanded uncertainty 0.3 %
Secondary standard ionization chamber, balance
Mn-54, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2003
CMC ID : EURAMET-RI-CH-00000GSN-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 3.00E6 Bq/g to 1.60E8 Bq/g
Relative expanded uncertainty 1.3 %
Secondary standard ionization chamber, balance
Cd-109, no further specifications
Reference standard : 4π(PC)γ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2010
CMC ID : EURAMET-RI-CH-00000GSU-1
 
Ionizing radiation
Activity , Single nuclide solution : 5.00E4 Bq to 3.00E7 Bq
Relative expanded uncertainty 1 %
Secondary standard ionization chamber, balance
Ge/Ga-68, no further specifications
Source of traceability : IRA/METAS
Approved on 22 May 2024
Institute service identifier : 1751
CMC ID : EURAMET-RI-CH-00000PLU-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 2.50E4 Bq/g to 1.50E7 Bq/g
Relative expanded uncertainty 0.5 %
Secondary standard ionization chamber, balance
Ir-192, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2020
CMC ID : EURAMET-RI-CH-00000GSG-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 5.00E4 Bq/g to 3.00E7 Bq/g
Relative expanded uncertainty 0.6 %
Secondary standard ionization chamber, balance
Ba-133, no further specifications
Reference standard : 4π(PC)γ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2014
CMC ID : EURAMET-RI-CH-00000GSA-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E5 Bq/g to 6.00E7 Bq/g
Relative expanded uncertainty 0.7 %
Secondary standard ionization chamber, balance
Co-57, no further specifications
Reference standard : 4π(PC) coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2004
CMC ID : EURAMET-RI-CH-00000GSO-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.50E4 Bq/g to 1.00E7 Bq/g
Relative expanded uncertainty 1 %
Secondary standard ionization chamber, balance
Cs-134, no further specifications
Reference standard : 4πβγ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2015
CMC ID : EURAMET-RI-CH-00000GSB-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 6.00E4 Bq/g to 4.00E7 Bq/g
Relative expanded uncertainty 1 %
Secondary standard ionization chamber, balance
I-131, no further specifications
Reference standard : 4πβγ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2013
CMC ID : EURAMET-RI-CH-00000GSX-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E7 Bq/g to 8.00E9 Bq/g
Relative expanded uncertainty 1.8 %
Secondary standard ionization chamber, balance
I-125, no further specifications
Reference standard : X-γ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2012
CMC ID : EURAMET-RI-CH-00000GSW-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1000 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 5.5 %
LS spectrometer, balance
Tl-204, no further specifications
Reference standard : LS counting (CIEMAT-NIST), standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2021
CMC ID : EURAMET-RI-CH-00000GSH-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 2.00E4 Bq/g to 1.30E7 Bq/g
Relative expanded uncertainty 0.6 %
Secondary standard ionization chamber, balance
Eu-152, no further specifications
Reference standard : 4π(PC)γ coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2018
CMC ID : EURAMET-RI-CH-00000GSE-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E5 Bq/g to 7.00E7 Bq/g
Relative expanded uncertainty 1.1 %
Secondary standard ionization chamber, balance
I-123, no further specifications
Reference standard : 4π(PC)γ coincidence counting, 4πγ NaI counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2011
CMC ID : EURAMET-RI-CH-00000GSV-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 1.00E4 Bq/g to 7.00E6 Bq/g
Relative expanded uncertainty 0.9 %
Secondary standard ionization chamber, balance
Y-88, no further specifications
Reference standard : 4π(PC) coincidence counting, standard weighting set
Source of traceability : IRA/METAS
Approved on 21 October 2001
Institute service identifier : EUR-RAD-IRA-2007
CMC ID : EURAMET-RI-CH-00000GSR-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.