In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Romania, IFIN-HH ("Horia Hulubei" National Institute of Research and Development for Physics and Nuclear Engineering)
Ionizing radiation
Activity , Single nuclide solid source : 100 Bq to 5000 Bq
Relative expanded uncertainty 5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Eu-152, solid source, cylinder, water equivalent, diameter 73 mm, height 40 mm, mass 170 g
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, NaI(Tl) crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2032
CMC ID : EURAMET-RI-RO-00000H05-1
 
Ionizing radiation
Activity , Single nuclide solid source : 4000 Bq to 4.00E5 Bq
Relative expanded uncertainty 3.5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Co-60, point source
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, NaI(Tl) crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2022
CMC ID : EURAMET-RI-RO-00000GZV-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E5 Bq/g
Relative expanded uncertainty 2 %
Liquid scintillation counting, balance
H-3, tritiated water, glass ampoule
Reference standard : 4P-LS-BP-00-00-TD, LSC-TDCR counter, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2001
CMC ID : EURAMET-RI-RO-00000GZ9-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 2 %
4πPC-γ coincidence counting, balance
Yb-169, solution, glass ampoule
Reference standard : 4P-PC-XR/AE-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2018
CMC ID : EURAMET-RI-RO-00000GZR-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 8 %
4πPC-γ coincidence counting, balance
Ag-110m, solution, glass ampoule
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2011
CMC ID : EURAMET-RI-RO-00000GZJ-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E5 Bq/g
Relative expanded uncertainty 2 %
4πPC-γ coincidence counting, balance
Cs-134, solution, glass ampoule
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2014
CMC ID : EURAMET-RI-RO-00000GZN-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 2 %
Liquid scintillation counting, balance
Tl-204, solution, glass ampoule
Reference standard : 4P-LS-BP-00-00-TD, LSC-TDCR counter, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2005
CMC ID : EURAMET-RI-RO-00000GZD-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E5 Bq/g
Relative expanded uncertainty 2 %
Liquid scintillation counting, balance
Ni-63, solution, glass ampoule
Reference standard : 4P-LS-BP-00-00-TD, LSC-TDCR counter, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2003
CMC ID : EURAMET-RI-RO-00000GZB-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 2 %
Liquid scintillation counting, balance
Sr-89, solution, glass ampoule
Reference standard : 4P-LS-BP-00-00-TD, LSC-TDCR counter, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2004
CMC ID : EURAMET-RI-RO-00000GZC-1
 
Ionizing radiation
Activity , Single nuclide solid source : 100 Bq to 5000 Bq
Relative expanded uncertainty 5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Ba-133, solid source, cylinder, water equivalent, diameter 73 mm, height 40 mm, mass 170 g
Reference standard : 4P-PC-XR/AE-NA-GR-CO, 4piPC-g system, NaI(Tl) crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2029
CMC ID : EURAMET-RI-RO-00000H02-1
 
Ionizing radiation
Activity , Single nuclide solid source : 100 Bq to 5000 Bq
Relative expanded uncertainty 5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Cs-134, solid source, cylinder, water equivalent, diameter 73 mm, height 40 mm, mass 170 g
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, NaI(Tl) crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2030
CMC ID : EURAMET-RI-RO-00000H03-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E4 Bq/g
Relative expanded uncertainty 3 %
4πPC-γ coincidence counting, balance
Tc-99m, solution, glass ampoule
Reference standard : 4P-PC-CE-NA-XR-CO, 4piPC-g system and UA-00-00-GH-GR-00, HPGe spectrometer, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2035
CMC ID : EURAMET-RI-RO-00000H08-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E4 Bq/g
Relative expanded uncertainty 2.5 %
4πPC-γ coincidence counting, balance
Co-57, solution, glass ampoule
Reference standard : 4P-PC-XR/AE-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2034
CMC ID : EURAMET-RI-RO-00000H07-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E5 Bq/g
Relative expanded uncertainty 2 %
LSC counting or 4πPC-γ coincidence counting, balance
Am-241, solution, glass ampoule
Reference standard : 4P-LS-AP-00-00-00 LSC-TDCR counter or 4P-PC-AP-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2006
CMC ID : EURAMET-RI-RO-00000GZE-1
 
Ionizing radiation
Activity , Single nuclide solid source : 100 Bq to 5000 Bq
Relative expanded uncertainty 5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Co-60, solid source, cylinder, water equivalent, diameter 73 mm, height 40 mm, mass 170 g
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, NaI(Tl) crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2028
CMC ID : EURAMET-RI-RO-00000H01-1
 
Ionizing radiation
Activity , Single nuclide solid source : 4000 Bq to 4.00E5 Bq
Relative expanded uncertainty 3.5 %
4πPC-γ coincidence counting, NaI(Tl) counting, balance
Ba-133, point source
Reference standard : 4P-PC-XR/AE-NA-GR-CO, 4piPC-g system, NaI(Tl)crystal, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2023
CMC ID : EURAMET-RI-RO-00000GZW-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 2 %
4πPC-γ coincidence counting, balance
Ir-192, solution, glass ampoule
Reference standard : 4P-PC-BP/XR/AE/CE-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2019
CMC ID : EURAMET-RI-RO-00000GZS-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8000 Bq/g
Relative expanded uncertainty 2 %
4πPC-γ coincidence counting, balance
Mn-54, solution, glass ampoule
Reference standard : 4P-PC-XR/AE-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2008
CMC ID : EURAMET-RI-RO-00000GZG-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.00E5 Bq/g
Relative expanded uncertainty 2 %
4πPC-γcoincidence counting, balance
Cs-137, solution, glass ampoule
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2015
CMC ID : EURAMET-RI-RO-00000GZO-1
 
Ionizing radiation
Activity per unit mass , Single nuclide solution : 4000 Bq/g to 8.99E5 Bq/g
Relative expanded uncertainty 2 %
4πPC-γ coincidence counting, balance
Co-60, solution, glass ampoule
Reference standard : 4P-PC-BP-NA-GR-CO, 4piPC-g system, standard balance
Source of traceability : IFIN-HH, National Institute of Metrology (NMI) for balance
Approved on 10 September 2013
Institute service identifier : EUR-RAD-IFIN-HH-2007
CMC ID : EURAMET-RI-RO-00000GZF-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.