In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Poland, GUM (Glowny Urzad Miar, Central Office of Measures)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solution 0.015 to 0.15 0.3 to 0.1 0.015 to 0.15 0.3 to 0.1
  • Mechanism for measurement service delivery : Secondary CRM No.5.4-6 plus calibration
  • Temperature for service: 25 °C
  • Approved on 06 December 2011
  • Institute service identifier : 5.4-6
  • CMC ID : EURAMET-QM-PL-00000065-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solution 0.15 to 11.5 0.1 0.15 to 11.5 0.1
  • Mechanism for measurement service delivery : Secondary CRM No.5.1-3 plus calibration
  • Temperature for service: 25 °C
  • Approved on 06 December 2011
  • Institute service identifier : 5.1-3
  • CMC ID : EURAMET-QM-PL-00000064-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 6.7 to 7.6 7.0E-3 6.7 to 7.6 7.0E-3
  • Mechanism for measurement service delivery : CRM GUM 3.5, CRM GUM 3.27, CRM GUM 3.6; plus calibration
  • Measurement temperature: 5 °C to 50 °C, data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2).
  • Approved on 22 November 2023
  • Institute service identifier : GUM 3.5, GUM 3.27, GUM 3.6
  • CMC ID : EURAMET-QM-PL-00000061-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 3.6 to 4.2 3.0E-3 3.8 to 4.2 3.0E-3
  • Mechanism for measurement service delivery : CRM GUM 3.4 plus calibration
  • Measurement temperature: 5 °C to 50 °C, data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2).
  • Approved on 22 November 2023
  • Institute service identifier : GUM 3.4
  • CMC ID : EURAMET-QM-PL-00000060-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 1.5 to 1.9 7.0E-3 1.5 to 1.9 7.0E-3
  • Mechanism for measurement service delivery : CRM GUM 3.1 plus calibration
  • Measurement temperature: 5 °C to 50 °C, data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2).
  • Approved on 22 November 2023
  • Institute service identifier : GUM 3.1
  • CMC ID : EURAMET-QM-PL-0000005Y-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 9.8 to 10.2 6.0E-3 9.8 to 10.2 6.0E-3
  • Mechanism for measurement service delivery : CRM GUM 3.8, plus calibration
  • Measurement temperature: 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2).
  • Approved on 22 November 2023
  • Institute service identifier : GUM 3.8
  • CMC ID : EURAMET-QM-PL-00000063-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 3.6 to 4.2 3.0E-3 3.6 to 4 3.0E-3
  • Mechanism for measurement service delivery : PRM GUM-03 plus calibration
  • Temperature range for service: 5 °C to 50 °C, values given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~ 0.010, k = 2)
  • Approved on 06 December 2011
  • Institute service identifier : 4.P-B
  • CMC ID : EURAMET-QM-PL-0000005Z-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 9 to 9.4 5.0E-3 9 to 9.4 5.0E-3
  • Mechanism for measurement service delivery : CRM GUM 3.7 plus calibration
  • Measurement temperature: 5 oC to 50 oC, data given for 25 oC. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2)
  • Approved on 01 September 2023
  • Institute service identifier : GUM 3.7
  • CMC ID : EURAMET-QM-PL-00000062-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 250 to 520 1.2 250 to 520 1.2
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/004-1
  • CMC ID : EURAMET-QM-PL-00000LWE-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
synthetic natural gas carbon dioxide 0.2 to 5 0.61 0.2 to 5 0.61
synthetic natural gas carbon dioxide 5 to 200 0.61 5 to 200 0.61
synthetic natural gas ethane 2 to 250 0.81 2 to 250 0.81
synthetic natural gas helium 0.5 to 25 0.63 0.5 to 25 0.63
synthetic natural gas hydrogen 5 to 100 0.86 5 to 100 0.86
synthetic natural gas isobutane 0.5 to 15 5.0 0.5 to 15 5.0
synthetic natural gas methane 500 to 999 0.1 500 to 999 0.1
synthetic natural gas n-butane 0.5 to 15 0.82 0.5 to 15 0.82
synthetic natural gas n-hexane 0.1 to 2.5 0.74 0.1 to 2.5 0.74
synthetic natural gas n-pentane 0.1 to 2.5 0.68 0.1 to 2.5 0.68
synthetic natural gas neo-pentane 0.1 to 2.5 2 0.1 to 2.5 2
synthetic natural gas nitrogen 1 to 5 0.89 to 0.42 1 to 5 0.89 to 0.42
synthetic natural gas nitrogen 5 to 250 0.42 5 to 250 0.42
synthetic natural gas propane 0.5 to 120 1.1 0.5 to 120 1.1
  • Uncertainty equation CMC : 2*(10^(-2.5051+1.0049*log(x)))/(x)*100
  • Uncertainty equation CRM : 2*(10^(-2.5051+1.0049*log(x)))/(x)*100
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • Approved on 17 May 2023
  • Institute service identifier : 008
  • CMC ID : EURAMET-QM-PL-000001NQ-4
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 0.52 to 10 1.2 0.52 to 10 1.2
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • Approved on 15 October 2019
  • Institute service identifier : GUM20/004-2
  • CMC ID : EURAMET-QM-PL-00000JO5-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 60 to 140 0.88 60 to 140 0.88
nitrogen carbon monoxide 5 to 50 0.88 5 to 50 0.88
nitrogen propane 0.2 to 2 0.88 0.2 to 2 0.88
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/006
  • CMC ID : EURAMET-QM-PL-000001NG-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 0.52 to 10 1.2 to 1.1 0.52 to 10 1.2 to 1.1
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/004-2
  • CMC ID : EURAMET-QM-PL-00000LWF-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 10 to 200 0.8 10 to 200 0.8
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/004
  • CMC ID : EURAMET-QM-PL-000001NW-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 250 to 520 1.2 250 to 520 1.2
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • Approved on 15 October 2019
  • Institute service identifier : GUM20/004-1
  • CMC ID : EURAMET-QM-PL-00000JO4-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon monoxide 0.01 to 1 1 to 0.4 0.01 to 1 0.6 to 0.3
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/003-3
  • CMC ID : EURAMET-QM-PL-000001NK-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon monoxide 10 to 200 0.4 10 to 200 0.3
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/003-1
  • CMC ID : EURAMET-QM-PL-000001NI-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen carbon monoxide 1 to 10 3 to 1 1 to 10 3 to 0.6
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/003-4
  • CMC ID : EURAMET-QM-PL-000001NS-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon monoxide 1 to 10 0.4 1 to 10 0.3
  • Mechanism for measurement service delivery : PRM, CRM, calibration
  • CRM, CALIBRATION
  • Approved on 22 October 2020
  • Institute service identifier : GUM20/003-2
  • CMC ID : EURAMET-QM-PL-000001NJ-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
high purity potassium chloride chloride expressed as potassium chloride 99.8 to 100 1.3E-2 99.95 to 100 1.3E-2
  • Mechanism for measurement service delivery : Calibration and GUM CRM (solid primary CRM)
  • Approved on 28 June 2018
  • Institute service identifier : GUM 0.1
  • CMC ID : EURAMET-QM-PL-000001KY-1
     

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.