Results for: National Physical Laboratory
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
819 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Denmark, DTU (Technical University of Denmark)
Ionizing radiation
Absorbed dose/rate to water , Passive dosimeter (Alanine, Radiochromic film, Perspex) : 0.2 kGy to 100 kGy
Relative expanded uncertainty 2.9 %
Irradiation in calibrated photon field
Co-60, Irradiation in reference Co-60 gamma ray field (Gamma cell)
Reference standard : Photon beam graphite calorimeter at National Physical Laboratory
Source of traceability : National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Institute service identifier : EUR-RAD-DTU-1001
CMC ID : EURAMET-RI-DK-00000H1R-1
 
Russian Federation, VNIIFTRI (Institute of Physical Technical and Radiotechnical Measurements, Rosstandart)
Hydrophones (underwater acoustics) , Free-field sensitivity
Measurement hydrophone
Absolute expanded uncertainty : 0.7 dB
IEC 60565, three- transducer spherical wave reciprocity in a laboratory tank
Frequency : 0.51 MHz to 1.0 MHz
Approved on 21 October 2001
CMC ID : COOMET-AUV-RU-000005ND-1
 
Hydrophones (underwater acoustics) , Free-field sensitivity
Measurement hydrophone
Absolute expanded uncertainty : 0.6 dB
IEC 60565, three- transducer spherical wave reciprocity in a laboratory tank
Frequency : 3.15 kHz to 200 kHz
Sound pressure : 1 Pa to 100 Pa
Approved on 21 October 2001
CMC ID : COOMET-AUV-RU-000005NB-1
 
Hydrophones (underwater acoustics) , Free-field sensitivity
Measurement hydrophone
Absolute expanded uncertainty : 0.6 dB
IEC 60565, three- transducer spherical wave reciprocity in a laboratory tank
Frequency : 0.21 MHz to 0.5 MHz
Approved on 21 October 2001
CMC ID : COOMET-AUV-RU-000005NC-1
 
Measurement microphones , Pressure sensitivity level (modulus)
Laboratory standard microphone type: IEC 61094-1 LS2P microphone
Absolute expanded uncertainty : 6.0E-2 dB to 0.5 dB
{"row_1":{"col_1":"Frequency, Hz","col_2":"Expanded uncertainty (k=2), dB"},"row_2":{"col_1":"1.995<br>","col_2":"0.07"},"row_3":{"col_1":"2.512","col_2":"0.06"},"row_4":{"col_1":"3.162","col_2":"0.06"},"row_5":{"col_1":"3.981<br>","col_2":"0.06"},"row_6":{"col_1":"5.012","col_2":"0.06"},"row_7":{"col_1":"6.310","col_2":"0.06<br>"},"row_8":{"col_1":"7.943","col_2":"0.06<br>"},"row_9":{"col_1":"10.000","col_2":"0.06<br>"},"row_10":{"col_1":"12.589<br>","col_2":"0.06"},"row_11":{"col_1":"15.849<br>","col_2":"0.06"},"row_12":{"col_1":"19.953","col_2":"0.06<br>"},"row_13":{"col_1":"25.119","col_2":"0.06"},"row_14":{"col_1":"31.623","col_2":"0.06"},"row_15":{"col_1":"39.811<br>","col_2":"0.06"},"row_16":{"col_1":"50.119<br>","col_2":"0.06<br>"},"row_17":{"col_1":"63.096<br>","col_2":"0.06<br>"},"row_18":{"col_1":"79.433<br>","col_2":"0.06"},"row_19":{"col_1":"100.000<br>","col_2":"0.06"},"row_20":{"col_1":"125.893<br>","col_2":"0.06<br>"},"row_21":{"col_1":"158.489<br>","col_2":"0.06"},"row_22":{"col_1":"199.526<br>","col_2":"0.06"},"row_23":{"col_1":"251.189<br>","col_2":"0.06"},"row_24":{"col_1":"316.228","col_2":"0.06<br>"},"row_25":{"col_1":"398.107<br>","col_2":"0.06"},"row_26":{"col_1":"501.187","col_2":"0.06<br>"},"row_27":{"col_1":"630.957","col_2":"0.06"},"row_28":{"col_1":"794.328","col_2":"0.06"},"row_29":{"col_1":"1000.000<br>","col_2":"0.06"},"row_30":{"col_1":"1258.925<br>","col_2":"0.06<br>"},"row_31":{"col_1":"1584.893","col_2":"0.06<br>"},"row_32":{"col_1":"1995.262","col_2":"0.06"},"row_33":{"col_1":"2511.886","col_2":"0.06"},"row_34":{"col_1":"3162.278<br>","col_2":"0.06"},"row_35":{"col_1":"3981.072<br>","col_2":"0.06"},"row_36":{"col_1":"5011.872","col_2":"0.06<br>"},"row_37":{"col_1":"6309.573","col_2":"0.06<br>"},"row_38":{"col_1":"7943.282","col_2":"0.06"},"row_39":{"col_1":"10000.000","col_2":"0.07"},"row_40":{"col_1":"12589.25<br>","col_2":"0.09"},"row_41":{"col_1":"15848.93<br>","col_2":"0.13"},"row_42":{"col_1":"19952.62<br>","col_2":"0.21"},"row_43":{"col_1":"25118.86<br>","col_2":"0.5"}}
Pressure reciprocity IEC 61094-2:2009
IEC 61094-2:2009
Frequency : From 2 Hz to 25 kHz
Approved on 21 August 2024
CMC ID : COOMET-AUV-RU-00000PX5-1
 
Measurement microphones , Pressure sensitivity level (modulus)
Laboratory standard microphone type: IEC 61094-1 LS1P microphone
Absolute expanded uncertainty : 3.0E-2 dB to 0.18 dB
{"row_1":{"col_1":"Frequency, Hz","col_2":"Expanded uncertainty, dB"},"row_2":{"col_1":"1.995","col_2":"0.18"},"row_3":{"col_1":"2.512","col_2":"0.13"},"row_4":{"col_1":"3.162","col_2":"0.10"},"row_5":{"col_1":"3.981","col_2":"0.08"},"row_6":{"col_1":"5.012","col_2":"0.06"},"row_7":{"col_1":"6.310","col_2":"0.05"},"row_8":{"col_1":"7.943","col_2":"0.04"},"row_9":{"col_1":"10.000","col_2":"0.04"},"row_10":{"col_1":"12.589","col_2":"0.04<br>"},"row_11":{"col_1":"15.849","col_2":"0.04"},"row_12":{"col_1":"19.953","col_2":"0.04<br>"},"row_13":{"col_1":"25.119","col_2":"0.04"},"row_14":{"col_1":"31.623","col_2":"0.04"},"row_15":{"col_1":"39.811","col_2":"0.04<br>"},"row_16":{"col_1":"50.119","col_2":"0.04<br>"},"row_17":{"col_1":"63.096","col_2":"0.04<br>"},"row_18":{"col_1":"79.433","col_2":"0.04"},"row_19":{"col_1":"100.000","col_2":"0.04"},"row_20":{"col_1":"125.893","col_2":"0.03"},"row_21":{"col_1":"158.489","col_2":"0.03<br>"},"row_22":{"col_1":"199.526","col_2":"0.03<br>"},"row_23":{"col_1":"251.189","col_2":"0.03<br>"},"row_24":{"col_1":"316.228","col_2":"0.03"},"row_25":{"col_1":"398.107","col_2":"0.03<br>"},"row_26":{"col_1":"501.187","col_2":"0.03<br>"},"row_27":{"col_1":"630.957","col_2":"0.03<br>"},"row_28":{"col_1":"794.328","col_2":"0.03<br>"},"row_29":{"col_1":"1000.000","col_2":"0.03"},"row_30":{"col_1":"1258.925<br>","col_2":"0.03"},"row_31":{"col_1":"1584.893<br>","col_2":"0.03"},"row_32":{"col_1":"1995.262<br>","col_2":"0.03"},"row_33":{"col_1":"2511.886<br>","col_2":"0.03"},"row_34":{"col_1":"3162.278","col_2":"0.04"},"row_35":{"col_1":"3981.072","col_2":"0.04"},"row_36":{"col_1":"5011.872","col_2":"0.04"},"row_37":{"col_1":"6309.573","col_2":"0.06"},"row_38":{"col_1":"7943.282<br>","col_2":"0.08"},"row_39":{"col_1":"10000.000","col_2":"0.13"}}
Pressure reciprocity IEC 61094-2:2009
IEC 61094-2:2009
Frequency : From 2 Hz to 10 kHz
Approved on 21 August 2024
CMC ID : COOMET-AUV-RU-00000PX4-1
 
United Kingdom, NPL (National Physical Laboratory)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount -of-substance fraction in nmol/mol Relative expanded uncertainty in % Amount -of-substance fraction in nmol/mol Relative expanded uncertainty in %
nitrogen 1,2,3-trimethylbenzene 1 to 500 2.5 1 to 500 2.5
nitrogen 1,2,4-trimethylbenzene 1 to 500 2.5 1 to 500 2.5
nitrogen 1,3,5-trimethylbenzene 1 to 500 2.5 1 to 500 2.5
nitrogen 1,3-butadiene 1 to 500 2 1 to 500 2
nitrogen 1-butene 1 to 500 2 1 to 500 2
nitrogen 1-pentene 1 to 500 2 1 to 500 2
nitrogen 2,2,4-trimethylpentane 1 to 500 2 1 to 500 2
nitrogen 2-methyl-1,3-butadiene 1 to 500 2 1 to 500 2
nitrogen 2-methylbutane 1 to 500 2 1 to 500 2
nitrogen 2-methylpentane 1 to 500 2 1 to 500 2
nitrogen benzene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen cis-2-butene 1 to 500 2 1 to 500 2
nitrogen ethane 1 to 500 2 1 to 500 2
nitrogen ethene 1 to 500 2 1 to 500 2
nitrogen ethylbenzene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen ethyne 1 to 500 1.0E1 to 2 1 to 500 1.0E1 to 2
nitrogen i-butane 1 to 500 3 1 to 500 3
nitrogen m-xylene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen n-butane 1 to 500 2 1 to 500 2
nitrogen n-heptane 1 to 500 2 1 to 500 2
nitrogen n-hexane 1 to 500 2 1 to 500 2
nitrogen n-octane 1 to 500 2 1 to 500 2
nitrogen n-pentane 1 to 500 2 1 to 500 2
nitrogen o-xylene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen p-xylene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen propane 1 to 500 2 1 to 500 2
nitrogen propene 1 to 500 2 1 to 500 2
nitrogen toluene 1 to 1.00E4 2 1 to 1.00E4 2
nitrogen trans-2-butene 1 to 500 2 1 to 500 2
nitrogen trans-2-pentene 1 to 500 2 1 to 500 2
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 05 April 2022
  • Institute service identifier : GA43
  • CMC ID : EURAMET-QM-GB-00000NNS-1,EURAMET-QM-GB-00000NNR-1,EURAMET-QM-GB-00000NNQ-1,EURAMET-QM-GB-00000NNB-1,EURAMET-QM-GB-00000NN7-1,EURAMET-QM-GB-00000NND-1,EURAMET-QM-GB-00000NNJ-1,EURAMET-QM-GB-00000NNG-1,EURAMET-QM-GB-00000NN9-1,EURAMET-QM-GB-00000NNE-1,EURAMET-QM-GB-00000NNI-1,EURAMET-QM-GB-00000NN8-1,EURAMET-QM-GB-00000NMZ-1,EURAMET-QM-GB-00000NN0-1,EURAMET-QM-GB-00000NNM-1,EURAMET-QM-GB-00000NN5-1,EURAMET-QM-GB-00000NN3-1,EURAMET-QM-GB-00000NNN-1,EURAMET-QM-GB-00000NN4-1,EURAMET-QM-GB-00000NNH-1,EURAMET-QM-GB-00000NNF-1,EURAMET-QM-GB-00000NNK-1,EURAMET-QM-GB-00000NNA-1,EURAMET-QM-GB-00000NNP-1,EURAMET-QM-GB-00000NNO-1,EURAMET-QM-GB-00000NN1-1,EURAMET-QM-GB-00000NN2-1,EURAMET-QM-GB-00000NNL-1,EURAMET-QM-GB-00000NN6-1,EURAMET-QM-GB-00000NNC-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount -of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount -of-substance fraction in mmol/mol Relative expanded uncertainty in %
refinery gas 1,3-butadiene 0.1 to 30 2.2 0.1 to 30 2.2
refinery gas 1-butene 0.15 to 15.5 1.8 to 0.45 0.15 to 15.5 1.8 to 0.45
refinery gas ethane 3 to 350 0.68 to 0.2 3 to 350 0.68 to 0.2
refinery gas ethene 1 to 200 0.65 to 0.2 1 to 200 0.65 to 0.2
refinery gas helium 10 to 700 0.2 10 to 700 0.2
refinery gas hydrogen 10 to 700 0.59 to 0.25 10 to 700 0.59 to 0.25
refinery gas isobutylene 0.18 to 12 1.6 to 0.45 0.18 to 12 1.6 to 0.45
refinery gas methane 10 to 850 0.48 to 0.15 10 to 850 0.48 to 0.15
refinery gas nitrogen 1 to 950 1 to 0.22 1 to 950 1 to 0.22
refinery gas propane 1 to 180 0.2 1 to 180 0.2
refinery gas propene 0.4 to 100 0.7 to 0.2 0.4 to 100 0.7 to 0.2
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 05 April 2023
  • Institute service identifier : GA46
  • CMC ID : EURAMET-QM-GB-00000O6G-1,EURAMET-QM-GB-00000O6H-1,EURAMET-QM-GB-00000O6D-1,EURAMET-QM-GB-00000O6C-1,EURAMET-QM-GB-00000O6L-1,EURAMET-QM-GB-00000O6J-1,EURAMET-QM-GB-00000O6I-1,EURAMET-QM-GB-00000O6B-1,EURAMET-QM-GB-00000O6K-1,EURAMET-QM-GB-00000O6F-1,EURAMET-QM-GB-00000O6E-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
liquefied petroleum gas (LPG); liquefied natural gas (LNG) 1,3-butadiene 4 to 20 4.5 4 to 20 4.5
liquefied petroleum gas (LPG); liquefied natural gas (LNG) 1-butene 5 to 100 0.8 5 to 100 0.8
liquefied petroleum gas (LPG); liquefied natural gas (LNG) ethane 5 to 50 2 1 to 50 2
liquefied petroleum gas (LPG); liquefied natural gas (LNG) i-butane 5 to 750 0.7 1 to 750 0.7
liquefied petroleum gas (LPG); liquefied natural gas (LNG) i-pentane 4 to 20 1.2 4 to 20 1.2
liquefied petroleum gas (LPG); liquefied natural gas (LNG) isobutylene 5 to 100 0.5 5 to 100 0.5
liquefied petroleum gas (LPG); liquefied natural gas (LNG) n-butane 5 to 100 0.7 5 to 100 0.7
liquefied petroleum gas (LPG); liquefied natural gas (LNG) n-pentane 3 to 20 2.8 3 to 20 2.8
liquefied petroleum gas (LPG); liquefied natural gas (LNG) propane 5 to 750 0.6 1 to 750 0.6
liquefied petroleum gas (LPG); liquefied natural gas (LNG) propene 5 to 50 0.7 1 to 50 0.7
  • Mechanism for measurement service delivery : PRGM and calibration
  • Approved on 28 June 2018
  • Institute service identifier : GA25
  • CMC ID : EURAMET-QM-GB-0000027A-1,EURAMET-QM-GB-00000279-1,EURAMET-QM-GB-00000273-1,EURAMET-QM-GB-00000276-1,EURAMET-QM-GB-0000027B-1,EURAMET-QM-GB-00000278-1,EURAMET-QM-GB-00000277-1,EURAMET-QM-GB-0000027C-1,EURAMET-QM-GB-00000274-1,EURAMET-QM-GB-00000275-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in nmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in nmol/mol Relative expanded uncertainty in %
nitrogen 1,8-cineole 2.5 to 1000 5 2.5 to 1000 5
nitrogen 3-carene 2.5 to 1000 2 2.5 to 1000 2
nitrogen alpha-pinene 2.5 to 1000 3 2.5 to 1000 3
nitrogen R-limonene 2.5 to 1000 2 2.5 to 1000 2
  • Mechanism for measurement service delivery : PRGM and calibration
  • Approved on 15 October 2019
  • Institute service identifier : GA06
  • CMC ID : EURAMET-QM-GB-00000JOI-1,EURAMET-QM-GB-00000JOG-1,EURAMET-QM-GB-00000JOF-1,EURAMET-QM-GB-00000JOH-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or methane 1-propanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane 2-methyl-2-propanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane 2-propanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane butanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane carbon disulfide 10 to 1000 1 10 to 1000 1
nitrogen or methane carbonyl sulfide 10 to 1000 1 10 to 1000 1
nitrogen or methane diethyl sulfide 10 to 1000 1 10 to 1000 1
nitrogen or methane dimethyl sulfide 10 to 1000 1 10 to 1000 1
nitrogen or methane ethanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane ethyl methyl sulfide 10 to 1000 1 10 to 1000 1
nitrogen or methane hydrogen sulfide 10 to 500 1 10 to 500 1
nitrogen or methane methanethiol 10 to 1000 1 10 to 1000 1
nitrogen or methane tetrahydrothiophene 10 to 1000 1 10 to 1000 1
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 16 June 2021
  • Institute service identifier : GA35
  • CMC ID : EURAMET-QM-GB-00000LY1-3,EURAMET-QM-GB-00000LY2-3,EURAMET-QM-GB-00000LY0-3,EURAMET-QM-GB-00000LY3-3,EURAMET-QM-GB-00000LXU-3,EURAMET-QM-GB-00000LXT-3,EURAMET-QM-GB-00000LXX-3,EURAMET-QM-GB-00000LXV-3,EURAMET-QM-GB-00000LXZ-3,EURAMET-QM-GB-00000LXW-3,EURAMET-QM-GB-00000N6I-1,EURAMET-QM-GB-00000LXY-3,EURAMET-QM-GB-00000LY4-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or methane 1-propanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane 2-methyl-2-propanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane 2-propanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane butanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane carbon disulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane carbonyl sulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane diethyl sulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane dimethyl sulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane ethanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane ethyl methyl sulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane hydrogen sulfide 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane methanethiol 1 to 10 2.5 to 1 1 to 10 2.5 to 1
nitrogen or methane tetrahydrothiophene 1 to 10 2.5 to 1 1 to 10 2.5 to 1
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 11 April 2021
  • Institute service identifier : GA34
  • CMC ID : EURAMET-QM-GB-00000LXN-3,EURAMET-QM-GB-00000LXO-3,EURAMET-QM-GB-00000LXM-3,EURAMET-QM-GB-00000LXP-3,EURAMET-QM-GB-00000LXG-3,EURAMET-QM-GB-00000LXD-3,EURAMET-QM-GB-00000LXJ-3,EURAMET-QM-GB-00000LXH-3,EURAMET-QM-GB-00000LXL-3,EURAMET-QM-GB-00000LXI-3,EURAMET-QM-GB-00000LXC-3,EURAMET-QM-GB-00000LXK-3,EURAMET-QM-GB-00000LXQ-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
air 2-butanone 100 to 1000 2 100 to 1000 2
air acetone 10 to 500 2 10 to 500 2
air ethanol 100 to 200 1.5 100 to 200 1.5
air methanol 10 to 100 3 to 2 10 to 100 3 to 2
air toluene 10 to 100 2 10 to 100 2
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 11 April 2021
  • Institute service identifier : GA36
  • CMC ID : EURAMET-QM-GB-00000LWT-2,EURAMET-QM-GB-00000LWS-2,EURAMET-QM-GB-00000LWI-2,EURAMET-QM-GB-00000LWJ-2,EURAMET-QM-GB-00000LWU-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Charge concentration in fC/cm3 Relative expanded uncertainty in % Charge concentration in % Relative expanded uncertainty in %
air airborne particles 0.15 to 3 1.2 to 0.98
  • Mechanism for measurement service delivery : Calibration
  • Approved on 11 April 2024
  • Institute service identifier : P02
  • CMC ID : EURAMET-QM-GB-0000025J-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Number concentration in cm-3 Relative expanded uncertainty in % Number concentration in % Relative expanded uncertainty in %
air airborne particles 100 to 2.00E4 3.5
  • Mechanism for measurement service delivery : Calibration
  • Approved on 11 April 2024
  • Institute service identifier : P01
  • CMC ID : EURAMET-QM-GB-0000025I-4
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount -of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount -of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or air ammonia 10 to 1000 2.9 10 to 1000 2.9
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 05 April 2023
  • Institute service identifier : GA41
  • CMC ID : EURAMET-QM-GB-00000NMN-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in nmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in nmol/mol Relative expanded uncertainty in %
nitrogen beta-pinene 2.5 to 1000 3 2.5 to 1000 3
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 15 June 2021
  • Institute service identifier : GA06
  • CMC ID : EURAMET-QM-GB-00000LWH-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or air carbon dioxide 5.00E-3 to 10 1.0E2 to 5.0E-2 5.00E-3 to 10 1.0E2 to 5.0E-2
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 22 October 2020
  • Institute service identifier : NPL/GA01
  • CMC ID : EURAMET-QM-GB-0000026F-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount -of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount -of-substance fraction in mmol/mol Relative expanded uncertainty in %
synthetic natural gas carbon dioxide 0.2 to 5 2.1 to 0.16 0.2 to 5 2.1 to 0.16
synthetic natural gas carbon dioxide 5 to 250 0.16 5 to 250 0.16
synthetic natural gas ethane 0.08 to 250 1.3 to 0.23 0.08 to 250 1.3 to 0.23
synthetic natural gas helium 0.1 to 25 1.5 to 0.53 0.1 to 25 1.5 to 0.53
synthetic natural gas hydrogen 5 to 300 0.59 5 to 300 0.59
synthetic natural gas i-butane 0.04 to 17 1.4 to 0.4 0.04 to 17 1.4 to 0.4
synthetic natural gas isopentane 0.025 to 6 2.6 to 0.55 0.025 to 6 2.6 to 0.55
synthetic natural gas methane 500 to 990 5.0E-2 500 to 990 5.0E-2
synthetic natural gas n-butane 0.04 to 17 1.4 to 0.4 0.04 to 17 1.4 to 0.4
synthetic natural gas n-hexane 8.00E-3 to 6 2.7 to 0.59 8.00E-3 to 6 2.7 to 0.59
synthetic natural gas n-pentane 0.025 to 6 1.6 to 0.52 0.025 to 6 1.6 to 0.52
synthetic natural gas neo-pentane 5.00E-3 to 6 3.8 to 0.65 5.00E-3 to 6 3.8 to 0.65
synthetic natural gas nitrogen 5 to 250 0.2 5 to 250 0.2
synthetic natural gas nitrogen 0.2 to 5 5.3 to 0.2 0.2 to 5 5.3 to 0.2
synthetic natural gas propane 0.08 to 120 1.3 to 0.21 0.08 to 120 1.3 to 0.21
  • Uncertainty equation CMC : Urel = 200*x-1*10(a+b*log(x))
      a = -4.9583
    b = 0.1957
    Urel (%) : Relative expanded uncertainty
    x (mol/mol) : Amount-of-substance fraction of carbon dioxide in the mixture
     
  • Uncertainty equation CRM : Urel = 200*x-1*10(a+b*log(x))
      a = -4.9583
    b = 0.1957
    Urel (%) : Relative expanded uncertainty
    x (mol/mol) : Amount-of-substance fraction of carbon dioxide in the mixture
     
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 06 April 2023
  • Institute service identifier : GA45
  • CMC ID : EURAMET-QM-GB-00000OWZ-1,EURAMET-QM-GB-00000O5Z-1,EURAMET-QM-GB-00000O61-1,EURAMET-QM-GB-00000O69-1,EURAMET-QM-GB-00000O6A-1,EURAMET-QM-GB-00000O63-1,EURAMET-QM-GB-00000O66-1,EURAMET-QM-GB-00000O60-1,EURAMET-QM-GB-00000O64-1,EURAMET-QM-GB-00000O68-1,EURAMET-QM-GB-00000O67-1,EURAMET-QM-GB-00000O65-1,EURAMET-QM-GB-00000O5Y-1,EURAMET-QM-GB-00000OWY-1,EURAMET-QM-GB-00000O62-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or air carbon dioxide 10 to 5.00E5 5.0E-2 10 to 5.00E5 5.0E-2
  • Mechanism for measurement service delivery : PRM and calibration
  • Approved on 22 October 2020
  • Institute service identifier : NPL/GA02
  • CMC ID : EURAMET-QM-GB-0000026G-3
     

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.