Results for: National Measurement Institute, Australia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
292 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Australia, NMIA (National Measurement Institute, Australia)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in cmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in cmol/mol Relative expanded uncertainty in %
liquefied petroleum gas (LPG) 1-butene 0.05 to 15 1.5 0.05 to 15 1.5
liquefied petroleum gas (LPG) ethane 0.05 to 15 1.5 to 2 0.05 to 15 1.5
liquefied petroleum gas (LPG) isobutane 0.05 to 99.9 0.9 0.05 to 99.9 0.9
liquefied petroleum gas (LPG) isopentane 0.05 to 15 2.5 0.05 to 15 2.5
liquefied petroleum gas (LPG) n-butane 0.05 to 99.9 0.75 0.05 to 99.9 0.75
liquefied petroleum gas (LPG) n-hexane 0.05 to 5 2 0.05 to 5 2
liquefied petroleum gas (LPG) n-pentane 0.05 to 15 2 0.05 to 15 2
liquefied petroleum gas (LPG) propane 0.05 to 99.9 0.35 0.05 to 99.9 0.35
liquefied petroleum gas (LPG) propene 0.05 to 15 0.6 0.05 to 15 0.6
  • Mechanism for measurement service delivery : PRM, CRM, PT values
  • Approved on 23 October 2019
  • Institute service identifier : LP1
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in pg/g Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
human serum 17beta-estradiol 100 to 250 5 to 2
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 30 August 2017
  • Institute service identifier : CRM31_bE
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Absolute expanded uncertainty in % Mass fraction in ng/g Absolute expanded uncertainty in %
1,2-dimethoxyethane 19-norandrosterone 10 to 1000 2.5 to 5 220 to 230 2 to 4
  • Mechanism for measurement service delivery : CRM MX003 and certification service
  • Approved on 08 July 2020
  • Institute service identifier : CRM MX003
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Absolute expanded uncertainty in % Mass fraction in ng/g Absolute expanded uncertainty in ng/g
freeze-dried urine 19-norandrosterone 1 to 100 3.5 to 1.0E1 2.13 0.17
  • Mechanism for measurement service delivery : CRM MX002
  • Approved on 13 July 2007
  • Institute service identifier : CRM MX002
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
human serum 25-hydroxyvitamin D2 2 to 120 1.0E1 to 3
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 19 June 2014
  • Institute service identifier : CRM26.1
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
human serum 25-hydroxyvitamin D3 2 to 120 1.0E1 to 3
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 19 June 2014
  • Institute service identifier : CRM26.1
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
prawn 3-amino-2-oxazolidinone 4 to 25 7.5 to 5 4.5 to 20.6 6.3 to 6
  • Mechanism for measurement service delivery : CRM MX012A, CRM MX012B
  • Approved on 19 June 2014
  • Institute service identifier : MX012AOZ
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
freeze-dried urine(reconstituted) 5α-androstane-3α,17β-diol 5 to 2000 8 to 1.5 5 to 50 6 to 3
  • Mechanism for measurement service delivery : CRM MX017 and certification service
  • Approved on 08 July 2020
  • Institute service identifier : CRM MX017
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
freeze-dried urine(reconstituted) 5β-androstane-3α,17β-diol 5 to 2000 8 to 1.5 20 to 70 6 to 3
  • Mechanism for measurement service delivery : CRM MX017 and certification service
  • Approved on 08 July 2020
  • Institute service identifier : CRM MX017
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
freeze-dried urine(reconstituted) androsterone 500 to 2000 8 to 1.5 1000 to 1700 3 to 1.5
  • Mechanism for measurement service delivery : CRM MX017 and certification service
  • Approved on 08 July 2020
  • Institute service identifier : CRM MX017
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
sea water arsenic 2 to 1000 1.0E1 to 5 2.96 8.8
  • Mechanism for measurement service delivery : CRM MX014
  • Approved on 19 June 2014
  • Institute service identifier : MX014_As
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
water arsenic 2 to 50 1.0E1 to 2.1
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 21 June 2021
  • Institute service identifier : NMIA_CS_SA_FW_As
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in ng/g Relative expanded uncertainty in %
sea water cadmium 1 to 1000 5 to 2 1.32 3
  • Mechanism for measurement service delivery : CRM MX014
  • Approved on 19 June 2014
  • Institute service identifier : MX014_Cd
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
rice, grains, flours, vegetables cadmium 0.1 to 100 1 to 4
  • Mechanism for measurement service delivery : Certification service
  • Approved on 13 June 2013
  • Institute service identifier : PM9
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in % Mass fraction in Absolute expanded uncertainty in
fresh water cadmium 0.01 to 100 1 to 4
  • Mechanism for measurement service delivery : Certification service
  • Approved on 12 March 2013
  • Institute service identifier : PM2
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
synthetic natural gas carbon dioxide 1 to 50 1 to 0.3 1 to 50 1 to 0.3
  • Mechanism for measurement service delivery : PRMs, CRMs, and PT reference values
  • Approved on 19 June 2014
  • Institute service identifier : RGM7
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 350 to 600 0.6 to 0.4 350 to 600 0.6 to 0.4
  • Mechanism for measurement service delivery : PRMs, CRMs, and PT reference values
  • Approved on 20 January 2016
  • Institute service identifier : RGM9
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
synthetic air carbon dioxide 350 to 600 0.6 to 0.4 350 to 600 0.6 to 0.4
  • Mechanism for measurement service delivery : PRMs, CRMs, and PT reference values
  • Approved on 20 January 2016
  • Institute service identifier : RGM10
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen or air carbon dioxide 10 to 5.00E4 0.3 10 to 5.00E4 0.3
  • Mechanism for measurement service delivery : PRM, CRM, PT values
  • Approved on 08 July 2020
  • Institute service identifier : Core2
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
δ13CVPDB (Carbon isotope ratio relative to VPDB) in ‰ Absolute expanded uncertainty in ‰ δ13CVPDB (Carbon isotope ratio relative to VPDB) in ‰ Absolute expanded uncertainty in ‰
high purity organic chemicals with molecular weight < 1000 g/mol carbon isotope delta (δ13C) -32.1 to -10.4 0.1 to 2 -32.1 to -10.4 0.1 to 2
  • Mechanism for measurement service delivery : CRM MX018 and certification service
  • δ13CVPDB-LSVEC (Carbon isotope ratio relative to VPDB-LSVEC)
  • Approved on 08 July 2020
  • Institute service identifier : CRM MX018

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.