Results for: MEF-32
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
15 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Canada, NRC (National Research Council)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg
food antimony 5 to 200 0.5 to 1.6E1
  • Mechanism for measurement service delivery : Calibration services
  • As presented in NRC's Record of Participation Table (graphical presentation), only one value d/U (-1.10 for As in 2003 ) out of a total of 65 is outside the -1.0 and 1.0 range, demonstrating our track record measurement capability for the past 22 years.
  • Approved on 23 August 2022
  • Institute service identifier : MEF-36
  • CMC ID : SIM-QM-CA-00000NQX-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg
food boron 0.2 to 300 1.0E-2 to 1.0E1 3.63 to 163 0.16 to 1.0E1
  • Mechanism for measurement service delivery : CRM VITA-1, CRM VITB-1, CRM DORM-5

  • As presented in NRC's Record of Participation Table (graphical presentation), only one value d/U (-1.10 for As in 2003 ) out of a total of 65 is outside the -1.0 and 1.0 range, demonstrating our track record measurement capability for the past 22 years.
     
  • Approved on 18 July 2022
  • Institute service identifier : MEF-37
  • CMC ID : SIM-QM-CA-00000NQZ-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, lobster, shrimp, squid) lead 5.00E-3 to 200 2.0E-3 to 2.0E1 0.01 to 0.404 2.0E-3 to 6.2E-2
  • Mechanism for measurement service delivery : CRM DOLT-5, CRM DORM-4, CRM TORT-3, CRM LUTS-1, CRM PRON-1, CRM SQID-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-22
  • CMC ID : SIM-QM-CA-000001EG-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish) magnesium 5 to 2.00E4 0.5 to 8.8E2 89.5 to 940 4.1 to 9.5E1
  • Mechanism for measurement service delivery : CRM LUTS-1, CRM DOLT-5, CRM DORM-4
  • Approved on 15 July 2017
  • Institute service identifier : MEF-23
  • CMC ID : SIM-QM-CA-000001EH-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
yeast methionine 70 to 2.00E4 4 to 6.0E2 5758 2.8E2
  • Mechanism for measurement service delivery : CRM SELM-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-3
  • CMC ID : SIM-QM-CA-000001DX-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food rubidium 20 to 500 2 to 2.5E1
  • Mechanism for measurement service delivery : Calibration services

  • As presented in NRC's Record of Participation Table (graphical presentation), only one value d/U (-1.10 for As in 2003 ) out of a total of 65 is outside the -1.0 and 1.0 range, demonstrating our track record measurement capability for the past 22 years
  • Approved on 30 August 2022
  • Institute service identifier : MEF-38
  • CMC ID : SIM-QM-CA-00000NR0-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, lobster) selenium 0.05 to 6000 1.5E-2 to 3.0E2 0.641 to 10.9 5.4E-2 to 1
  • Mechanism for measurement service delivery : CRM DOLT-5, CRM DORM-4, CRM TORT-3, CRM LUTS-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-30
  • CMC ID : SIM-QM-CA-000001EO-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
yeast selenomethionine 60 to 1.00E4 1 to 8.0E2 3448 1.5E2
  • Mechanism for measurement service delivery : CRM SELM-1
  • Approved on 19 December 2013
  • Institute service identifier : MEF-2
  • CMC ID : SIM-QM-CA-000001DW-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish) silver 0.01 to 50 3.0E-3 to 2 0.0252 to 2.05 5.0E-3 to 8.0E-2
  • Mechanism for measurement service delivery : CRM DOLT-5, CRM DORM-4, CRM LUTS-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-31
  • CMC ID : SIM-QM-CA-000001EP-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, beef) sodium 100 to 5.00E4 2.0E1 to 2.5E3 2100 to 9900 1.0E2 to 1.6E3
  • Mechanism for measurement service delivery : Value Assignment of materials for NRC, 20 intercomparisons conducted annually CRM DOLT-5, CRM BOVM-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-32
  • CMC ID : SIM-QM-CA-000001EQ-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, lobster) strontium 0.02 to 300 7.0E-3 to 5 2.46 to 36.5 0.28 to 1.6
  • Mechanism for measurement service delivery : CRM DOLT-5, CRM TORT-3, CRM DORM-4,CRM LUTS-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-33
  • CMC ID : SIM-QM-CA-000001ER-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
calcium carbonate strontium 1 to 6000 0.1 to 1.0E2 2055 7.9E1
  • Mechanism for measurement service delivery : CRM FEBS-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-12
  • CMC ID : SIM-QM-CA-000001E6-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg mass fraction, mg/kg in mg/kg Absolute expanded uncertainty in mg/kg
food sulfur 400 to 5.00E4 4.0E1 to 1.2E3
  • Mechanism for measurement service delivery : Calibration service
  • As presented in NRC's Record of Participation Table (graphical presentation), only one value d/U (-1.10 for As in 2003 ) out of a total of 65 is outside the -1.0 and 1.0 range, demonstrating our track record measurement capability for the past 22 years.
     
  • Approved on 18 July 2022
  • Institute service identifier : MEF-39
  • CMC ID : SIM-QM-CA-00000NR7-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, lobster) vanadium 7.00E-3 to 500 1.0E-3 to 2.0E1 0.51 to 9.1 0.14 to 0.4
  • Mechanism for measurement service delivery : CRM TORT-3, CRM DORM-4 , CRM DOLT-5
  • Approved on 15 July 2017
  • Institute service identifier : MEF-34
  • CMC ID : SIM-QM-CA-000001ES-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg
food (fish, lobster, beef) zinc 0.5 to 3000 3.0E-2 to 7.5E1 12.4 to 142 0.8 to 1.4E1
  • Mechanism for measurement service delivery : CRM DOLT-5, CRM DORM-4, CRM TORT-3, CRM BOVM-1, CRM LUTS-1
  • Approved on 15 July 2017
  • Institute service identifier : MEF-35
  • CMC ID : SIM-QM-CA-000001ET-1
     

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.