Results for: Kazinmetr
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
38 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Kazakhstan, KazStandard (Kazakhstan Institute of Standardization and Metrology)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mol/mol Absolute expanded uncertainty in mol/mol
nitrogen carbon dioxide 0.04 to 0.16 1.5 0.04 to 0.16 1.5
nitrogen carbon monoxide 5.00E-3 to 0.05 1.5 5.00E-3 to 0.05 1.5
nitrogen propane 1.00E-4 to 3.00E-3 1.5 1.00E-4 to 3.00E-3 1.5
  • Mechanism for measurement service delivery : PRM, SRMs plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 27 May 2020
  • Institute service identifier : KazInMetr/4.2.1
  • CMC ID : COOMET-QM-KZ-000001VB-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen or air carbon monoxide 1.00E-3 to 0.01 2.2 1.00E-3 to 0.01 2.2
  • Mechanism for measurement service delivery : PRM, SRMs plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 27 May 2020
  • Institute service identifier : KazInMetr/4.2.3
  • CMC ID : COOMET-QM-KZ-000001VE-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mol/mol Relative expanded uncertainty in %
nitrogen oxygen 0.05 to 0.3 0.3 0.05 to 0.3 0.3
  • Mechanism for measurement service delivery : PRM, SRMs plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 27 May 2020
  • Institute service identifier : KazInMetr/4.2.2
  • CMC ID : COOMET-QM-KZ-000001VD-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen propane 0.1 to 5 1.5 0.1 to 5 1.5
  • Mechanism for measurement service delivery : PRM, SRMs: KZ.03.01.00113-2009, KZ.03.01.00526-2015, KZ.03.01.00539-2015, KZ.03.01.00540-2015, KZ.03.01.00541-2015, KZ.03.01.00543-2015 plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 27 May 2020
  • Institute service identifier : KazInMetr/4.2.4
  • CMC ID : COOMET-QM-KZ-000001VF-2
     
Form , Straightness standards : 0 µm to 50 µm
Straightness edge: straightness deviation
Absolute expanded uncertainty : 0 µm to 0.8 µm
0.2L L in m
The uncertainty is expressed in µm
(see Parameter)
Comparison with straight edge: autocollimators
Length L : up to 4 m
Approved on 22 February 2021
Institute service identifier : COO-L-KazInMetr 1431
CMC ID : COOMET-L-KZ-00000AEV-2
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC(KazInMetr)
Absolute expanded uncertainty : 9.7E1 ns
GPS common view comparison against UTC(KZ)
Pulse amplitude : > 1 V
Slew rate : > 0.5 V/ns
Averaging time : 5 days
Distance : < 1500 km
Approved on 13 March 2015
CMC ID : COOMET-TF-KZ-000006ZO-3
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 419.527 °C
Thermocouple (type R and S)
Absolute expanded uncertainty : 0.3 °C
Calibration at zinc fixed point
Temperature-controlled furnace : 3 zone
Approved on 15 November 2016
Institute service identifier : KazInMetr/6
CMC ID : COOMET-T-KZ-000007ZI-1
 
Items for defining ITS-90 , Temperature : 0.01 °C
Water triple point cell
Absolute expanded uncertainty : 0.15 mK
Direct comparison
Thermostat : ice bath
Approved on 06 September 2013
Institute service identifier : KazInMetr/1
CMC ID : COOMET-T-KZ-000007ZD-1
 
Impedance (up to the MHz range) , Capacitance for low loss capacitors : 10 pF to 100 pF
Standard capacitor
Relative expanded uncertainty
{"row_1":{"col_1":"","col_2":"Expanded uncertainty in µF/F"},"row_2":{"col_1":"10 pF","col_2":"0.72"},"row_3":{"col_1":"100 pF","col_2":"0.84"}}
0.72 to 0.84

The uncertainty is expressed in µF/F

Digital transformer bridge by direct measurement
Frequency : 1 kHz
Temperature : (20 ± 0.5) °C
Approved on 29 May 2017
Institute service identifier : KazInMetr/EM-K4
CMC ID : COOMET-EM-KZ-000009P0-1
 
Items for defining ITS-90 , Temperature : 660.323 °C
Standart platinum resistance thermometer
Absolute expanded uncertainty : 8.2 mK
Aluminium fixed point
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : KazInMetr/8
CMC ID : COOMET-T-KZ-00000KHM-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 660.323 °C
Alumunium cell
Absolute expanded uncertainty : 8.2 mK
Direct comparison
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : KazInMetr/7
CMC ID : COOMET-T-KZ-00000KHJ-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC(KazInMetr)
Absolute expanded uncertainty : 5.1 ns
Time interval measurement
Pulse amplitude : > 1 V
Slew rate : > 0.5 V/ns
Approved on 13 March 2015
CMC ID : COOMET-TF-KZ-000006ZM-3
 
Frequency , Frequency : 5 MHz
Remote frequency standard
Relative expanded uncertainty : 1.0E-12 Hz/Hz
GPS common view comparison against UTC
Averaging time : 5 days
Baseline length from KazInMetr : < 1500 km
Approved on 13 March 2015
CMC ID : COOMET-TF-KZ-00000702-2
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 1.0E-12 Hz/Hz
Frequency comparator
Averaging time : 1 s
Amplitude : 0.8 V to 1.2 V
Approved on 24 October 2011
Institute service identifier : RP UKF "KazInMetr" 07
CMC ID : COOMET-TF-KZ-000006ZW-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 231.928 °C
Tin cell
Absolute expanded uncertainty : 1.9 mK
Direct comparison
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : KazInMetr/7
CMC ID : COOMET-T-KZ-00000KHH-1
 
Form , Straightness standards : 0 µm to 50 µm
Straight edge: staightness
Absolute expanded uncertainty : 0.16 µm to 0.8 µm
0.16L L in m
The uncertainty is expressed in µm
(see Parameter)
Electronic levels
Length L : >0 m to 4 m
Approved on 22 February 2021
Institute service identifier : COO-L-KazInMetr 1432
CMC ID : COOMET-L-KZ-00000MYN-1
 
Frequency , Frequency : 10 MHz
Remote frequency standard
Relative expanded uncertainty : 1.0E-12 Hz/Hz
GPS common view comparison against UTC
Averaging time : 5 days
Baseline length from KazInMetr : < 1500 km
Approved on 13 March 2015
CMC ID : COOMET-TF-KZ-00000703-2
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 2.7E-13 Hz/Hz
Frequency comparator
Averaging time : 1E+03 s
Amplitude : 0.8 V to 1.2 V
Approved on 24 October 2011
Institute service identifier : RP UKF "KazInMetr" 09
CMC ID : COOMET-TF-KZ-000006ZY-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 2.7E-13 Hz/Hz
Frequency comparator
Averaging time : 1E+03 s
Amplitude : 0.8 V to 1.2 V
Approved on 24 October 2011
Institute service identifier : RP UKF "KazInMetr" 08
CMC ID : COOMET-TF-KZ-000006ZX-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 1.0E-12 Hz/Hz
Frequency comparator
Averaging time : 1 s
Amplitude : 0.8 V to 1.2 V
Approved on 24 October 2011
Institute service identifier : RP UKF "KazInMetr" 06
CMC ID : COOMET-TF-KZ-000006ZV-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.