Czechia, IPE/ASCR (Institute of Photonics and Electronics, Czech Academy of Sciences)
Time interval , Time interval : 0 s to 1 s
Time difference source
Absolute expanded uncertainty : 0.1 ns
Time difference meter
Slewing rate : > 0.5 V/ns
Approved on 02 May 2006
Institute service identifier : IPE/17
CMC ID : EURAMET-TF-CZ-00000B4I-1
 
Time interval , Time interval : 1 s
Time difference meter
Absolute expanded uncertainty : 0.1 ns
Time difference source
Slewing rate : > 0.5 V/ns
Approved on 02 May 2006
Institute service identifier : IPE/19
CMC ID : EURAMET-TF-CZ-00000B4J-1
 
Frequency , Frequency : 10 MHz
Frequency counter
Relative expanded uncertainty : 9.0E-12 Hz/Hz
Frequency source
Averaging time : 1 s
Approved on 02 May 2006
Institute service identifier : IPE/15
CMC ID : EURAMET-TF-CZ-00000B4S-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC
Absolute expanded uncertainty : 1.0E1 ns
Comparison against post-processed UTC
Slewing rate : > 0.5 V/ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/3
CMC ID : EURAMET-TF-CZ-00000B4E-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC
Absolute expanded uncertainty : 4.0E1 ns
Comparison against predicted UTC
Prediction time : 20 days
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/2
CMC ID : EURAMET-TF-CZ-00000B4D-1
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 2.0E-13 Hz/Hz
Phase time difference multiplication
Averaging time : 1 s
Relative frequency difference : < 1E-11
For evaluation of frequency instability
Approved on 02 May 2006
Institute service identifier : IPE/12
CMC ID : EURAMET-TF-CZ-00000B4P-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-14 Hz/Hz
Phase time measurement
Averaging time : 1 day
Approved on 02 May 2006
Institute service identifier : IPE/7
CMC ID : EURAMET-TF-CZ-00000B4K-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC
Absolute expanded uncertainty : 4.2E1 ns
GPS common view comparison against predicted UTC
Prediction time : 20 days
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/5
CMC ID : EURAMET-TF-CZ-00000B4G-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 2.0E-13 Hz/Hz
Phase time difference multiplication
Averaging time : 1 s
Relative frequency difference : < 1E-11
For evaluation of frequency instability
Approved on 02 May 2006
Institute service identifier : IPE/11
CMC ID : EURAMET-TF-CZ-00000B4O-1
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-13 Hz/Hz
Phase time measurement
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : IPE/10
CMC ID : EURAMET-TF-CZ-00000B4N-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-13 Hz/Hz
Phase time measurement
Averaging time : 1000 s
Approved on 02 May 2006
Institute service identifier : IPE/8
CMC ID : EURAMET-TF-CZ-00000B4L-1
 
Frequency , Frequency : 5 MHz
Frequency counter
Relative expanded uncertainty : 9.0E-12 Hz/Hz
Frequency source
Averaging time : 1 s
Approved on 02 May 2006
Institute service identifier : IPE/14
CMC ID : EURAMET-TF-CZ-00000B4R-1
 
Frequency , Frequency : 1 Hz
Remote frequency standard
Relative expanded uncertainty : 1.0E-13 Hz/Hz
GPS common view comparison against UTC(TP) frequency
Averaging time : 1 day
Approved on 02 May 2006
Institute service identifier : IPE/13
CMC ID : EURAMET-TF-CZ-00000B4Q-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC(IPE/ASCR)
Absolute expanded uncertainty : 1.0E1 ns
GPS common view comparison against UTC(TP)
Averaging time : 1 day
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/4
CMC ID : EURAMET-TF-CZ-00000B4F-2
 
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC(IPE/ASCR)
Absolute expanded uncertainty : 0.5 ns
Direct comparison against UTC(TP)
Slewing rate : > 0.5 V/ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/1
CMC ID : EURAMET-TF-CZ-00000B4C-2
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC
Absolute expanded uncertainty : 1.5E1 ns
GPS common view comparison against postprocessed UTC
Averaging time : 1 day
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 02 May 2006
Institute service identifier : IPE/6
CMC ID : EURAMET-TF-CZ-00000B4H-1
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-14 Hz/Hz
Phase time measurement
Averaging time : 1 day
Approved on 02 May 2006
Institute service identifier : IPE/9
CMC ID : EURAMET-TF-CZ-00000B4M-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.