Results for: Indonesia "SNSU-BSN"
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Indonesia, SNSU-BSN (National Measurement Standard - National Standardization Agency of Indonesia)
Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
pH in |
Absolute expanded uncertainty in |
pH in |
Absolute expanded uncertainty in |
aqueous buffer solution |
3.8 to 4.2 |
4.0E-3 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Buffer name : Phthalate buffer.
Measurement temperature : 15 °C, 25 °C, 37 °C.
The declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
-
Approved on
15 June 2021
-
Institute service identifier : IDNRM-MC-1-001
-
CMC ID :
APMP-QM-ID-000004XZ-2
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/kg |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
water, aqueous-based beverages, aqueous-based condiments |
benzoic acid |
50 to 500 |
5 to 8 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
11 April 2021
-
Institute service identifier : IDNRM-MO-2-001
-
CMC ID :
APMP-QM-ID-000004Y0-2
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/kg |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
water, aqueous-based beverages, aqueous-based condiments |
methylparaben |
50 to 500 |
6 to 9 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
15 June 2021
-
Institute service identifier : IDNRM-MO-2-001
-
CMC ID :
APMP-QM-ID-000004Y1-2
Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
Mass fraction in mg/kg |
Relative expanded uncertainty in % |
Mass fraction in % |
Absolute expanded uncertainty in % |
water, aqueous-based beverages, aqueous-based condiments |
n-Butyl paraben |
50 to 500 |
7 to 1.0E1 |
|
|
-
Mechanism for measurement service delivery :
Calibration
-
Approved on
15 June 2021
-
Institute service identifier : IDNRM-MO-2-001
-
CMC ID :
APMP-QM-ID-000004Y2-2
Sound calibrators ,
Sound pressure level
:
94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa)
Sound calibrator
Absolute expanded uncertainty
:
0.1 dB
Calibrated measurement microphone
Frequency : 1 kHz
Microphone type : LS2P
Approved on 09 January 2012
Institute service identifier : A2
CMC ID :
APMP-AUV-ID-00000D81-1
Measurement microphones ,
Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty
:
6.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 63 Hz to 2.5 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID :
APMP-AUV-ID-00000D82-1
Measurement microphones ,
Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty
:
7.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 3.15 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID :
APMP-AUV-ID-00000D83-1
Mass ,
Mass
:
10 kg
Mass standard
Absolute expanded uncertainty
:
1.1 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 22
CMC ID :
APMP-M-ID-00000D7T-1
Mass ,
Mass
:
5 kg
Mass standard
Absolute expanded uncertainty
:
0.6 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 21
CMC ID :
APMP-M-ID-00000D7S-1
Mass ,
Mass
:
2 kg
Mass standard
Absolute expanded uncertainty
:
0.2 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 20
CMC ID :
APMP-M-ID-00000D7R-1
Mass ,
Mass
:
20 kg
Mass standard
Absolute expanded uncertainty
:
8 mg
Comparison in air
E2 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 23
CMC ID :
APMP-M-ID-00000D7U-1
Pressure ,
Gauge pressure: oil medium
:
50 MPa to 100 MPa
Pressure balance
Absolute expanded uncertainty
2.8E-04P P pressure in Mpa
The uncertainty is expressed in MPa
Direct comparison with pressure standard: crossfloat
Uncertainty values range from 14000 Pa to 28000 Pa
Approved on 23 March 2007
CMC ID :
APMP-M-ID-00000D7Y-1
Pressure ,
Gauge pressure: oil medium
:
0.5 MPa to 5 MPa
Pressure balance
Absolute expanded uncertainty
1E-04P P pressure in Mpa
The uncertainty is expressed in MPa
Direct comparison with pressure standard: crossfloat
Uncertainty values range from 50 Pa to 500 Pa
Approved on 23 March 2007
CMC ID :
APMP-M-ID-00000D7W-1
Time interval ,
Time interval
:
1.00E-8 s to 1.00E-6 s
Rise/fall time source
Absolute expanded uncertainty
:
2 ns
Time interval measurement
Slew rate : > 0.5 V/ns
Total time interval : 100 s, 10 measurements
Approved on 24 June 2019
Institute service identifier : SNSU-BSN/I.MF.3.02
CMC ID :
APMP-TF-ID-00000FEK-1
Mass ,
Mass
:
50 mg
Mass standard
Absolute expanded uncertainty
:
0.9 µg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 6
CMC ID :
APMP-M-ID-00000D7D-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
0 °C to 100 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty
:
3.0E-2 °C
Comparison in bath
Liquid bath : silicon oil
Total immersion, Mercury filled, 0.01 °C graduations.
Approved on 27 February 2018
Institute service identifier : 1.3.3
CMC ID :
APMP-T-ID-00000D9B-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
200 °C to 500 °C
Radiation thermometer
Absolute expanded uncertainty
:
1.4 °C to 2.8 °C
Comparison using variable temperature blackbody furnace
Wavelength : 8 µm to 12 µm
Approved on 10 November 2015
Institute service identifier : 2.2.3
CMC ID :
APMP-T-ID-00000D94-1
Items for defining ITS-90 ,
Temperature
:
1000 °C to 1500 °C
Radiation thermometer
Absolute expanded uncertainty
:
1.8 °C to 2.6 °C
Comparison using variable temperature blackbody furnace
Wavelength : 0.65 µm
Approved on 10 November 2015
Institute service identifier : 2.2.2
CMC ID :
APMP-T-ID-00000D92-1
Linear vibration ,
Acceleration output (modulus)
:
5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty
:
1.3 %
ISO 16063-21
Frequency : 2500 Hz to 5000 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID :
APMP-AUV-ID-00000D8F-1
Linear vibration ,
Acceleration output (modulus)
:
5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty
:
1.1 %
ISO 16063-21
Frequency : 63 Hz to 250 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID :
APMP-AUV-ID-00000D8P-1