Results for: Indonesia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
148 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Indonesia, SNSU-BSN (National Measurement Standard - National Standardization Agency of Indonesia)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 3.8 to 4.2 4.0E-3
  • Mechanism for measurement service delivery : Calibration
  • Buffer name : Phthalate buffer.
    Measurement temperature : 15 °C, 25 °C, 37 °C.
    The declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
     
  • Approved on 15 June 2021
  • Institute service identifier : IDNRM-MC-1-001
  • CMC ID : APMP-QM-ID-000004XZ-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments benzoic acid 50 to 500 5 to 8
  • Mechanism for measurement service delivery : Calibration
  • Approved on 11 April 2021
  • Institute service identifier : IDNRM-MO-2-001
  • CMC ID : APMP-QM-ID-000004Y0-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments methylparaben 50 to 500 6 to 9
  • Mechanism for measurement service delivery : Calibration
  • Approved on 15 June 2021
  • Institute service identifier : IDNRM-MO-2-001
  • CMC ID : APMP-QM-ID-000004Y1-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments n-Butyl paraben 50 to 500 7 to 1.0E1
  • Mechanism for measurement service delivery : Calibration
  • Approved on 15 June 2021
  • Institute service identifier : IDNRM-MO-2-001
  • CMC ID : APMP-QM-ID-000004Y2-2
     
Sound calibrators , Sound pressure level : 94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa)
Sound calibrator
Absolute expanded uncertainty : 0.1 dB
Calibrated measurement microphone
Frequency : 1 kHz
Microphone type : LS2P
Approved on 09 January 2012
Institute service identifier : A2
CMC ID : APMP-AUV-ID-00000D81-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 6.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 63 Hz to 2.5 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID : APMP-AUV-ID-00000D82-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 7.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 3.15 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID : APMP-AUV-ID-00000D83-1
 
Mass , Mass : 10 kg
Mass standard
Absolute expanded uncertainty : 1.1 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 22
CMC ID : APMP-M-ID-00000D7T-1
 
Mass , Mass : 5 kg
Mass standard
Absolute expanded uncertainty : 0.6 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 21
CMC ID : APMP-M-ID-00000D7S-1
 
Mass , Mass : 2 kg
Mass standard
Absolute expanded uncertainty : 0.2 mg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 20
CMC ID : APMP-M-ID-00000D7R-1
 
Mass , Mass : 20 kg
Mass standard
Absolute expanded uncertainty : 8 mg
Comparison in air
E2 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 23
CMC ID : APMP-M-ID-00000D7U-1
 
Pressure , Gauge pressure: oil medium : 50 MPa to 100 MPa
Pressure balance
Absolute expanded uncertainty
2.8E-04P

P pressure in Mpa

The uncertainty is expressed in MPa

Direct comparison with pressure standard: crossfloat
Uncertainty values range from 14000 Pa to 28000 Pa
Approved on 23 March 2007
CMC ID : APMP-M-ID-00000D7Y-1
 
Pressure , Gauge pressure: oil medium : 0.5 MPa to 5 MPa
Pressure balance
Absolute expanded uncertainty
1E-04P

P pressure in Mpa

The uncertainty is expressed in MPa

Direct comparison with pressure standard: crossfloat
Uncertainty values range from 50 Pa to 500 Pa
Approved on 23 March 2007
CMC ID : APMP-M-ID-00000D7W-1
 
Time interval , Time interval : 1.00E-8 s to 1.00E-6 s
Rise/fall time source
Absolute expanded uncertainty : 2 ns
Time interval measurement
Slew rate : > 0.5 V/ns
Total time interval : 100 s, 10 measurements
Approved on 24 June 2019
Institute service identifier : SNSU-BSN/I.MF.3.02
CMC ID : APMP-TF-ID-00000FEK-1
 
Mass , Mass : 50 mg
Mass standard
Absolute expanded uncertainty : 0.9 µg
Comparison in air
E1 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 6
CMC ID : APMP-M-ID-00000D7D-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 100 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty : 3.0E-2 °C
Comparison in bath
Liquid bath : silicon oil
Total immersion, Mercury filled, 0.01 °C graduations.
Approved on 27 February 2018
Institute service identifier : 1.3.3
CMC ID : APMP-T-ID-00000D9B-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 200 °C to 500 °C
Radiation thermometer
Absolute expanded uncertainty : 1.4 °C to 2.8 °C
Comparison using variable temperature blackbody furnace
Wavelength : 8 µm to 12 µm
Approved on 10 November 2015
Institute service identifier : 2.2.3
CMC ID : APMP-T-ID-00000D94-1
 
Items for defining ITS-90 , Temperature : 1000 °C to 1500 °C
Radiation thermometer
Absolute expanded uncertainty : 1.8 °C to 2.6 °C
Comparison using variable temperature blackbody furnace
Wavelength : 0.65 µm
Approved on 10 November 2015
Institute service identifier : 2.2.2
CMC ID : APMP-T-ID-00000D92-1
 
Linear vibration , Acceleration output (modulus) : 5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty : 1.3 %
ISO 16063-21
Frequency : 2500 Hz to 5000 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID : APMP-AUV-ID-00000D8F-1
 
Linear vibration , Acceleration output (modulus) : 5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty : 1.1 %
ISO 16063-21
Frequency : 63 Hz to 250 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID : APMP-AUV-ID-00000D8P-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.