Results for: France "LNE-SYRTE"
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
France, LNE-SYRTE (Observatoire de Paris/Systèmes de Référence Temps-Espace)
Time interval ,
Time interval
:
-1 s to 1 s
Delay meter
Absolute expanded uncertainty
:
5 ns
GPS receiver relative calibration
Averaging time : 3 d
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/80
CMC ID :
EURAMET-TF-FR-00000FHA-1
Time scale difference ,
Time scale difference
:
-1 s to 1 s
Local clock vs UTC(OP)
Absolute expanded uncertainty
:
1 ns
Time interval counter
Pulse amplitude : > 1 V on 50 ohm
Rise time : < 5 ns
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/3
CMC ID :
EURAMET-TF-FR-00000FH7-3
Time scale difference ,
Time scale difference
:
-1 s to 1 s
Remote clock vs UTC(OP)
Absolute expanded uncertainty
:
1.0E1 ns
GPS TAIP3 common view
Averaging time : 1 d
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/75
CMC ID :
EURAMET-TF-FR-00000FH6-3
Time scale difference ,
Time scale difference
:
-1 s to 1 s
Remote clock vs UTC
Absolute expanded uncertainty
:
4.2E1 ns
GPS TAIP3 common view
Averaging time : 1 d
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/77
CMC ID :
EURAMET-TF-FR-00000FH9-1
Frequency ,
Frequency
:
-1.00E-10 Hz/Hz to 1.00E-10 Hz/Hz
Remote frequency standard
Relative expanded uncertainty
:
1.0E-13 Hz/Hz
Remote comparison to UTC(OP) via GPS
Averaging time : 1 d
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/79
CMC ID :
EURAMET-TF-FR-00000FHG-1
Time scale difference ,
Time scale difference
:
-1 s to 1 s
Local clock vs UTC
Absolute expanded uncertainty
:
4.0E1 ns
Time interval counter
Pulse amplitude : > 1 V on 50 ohm
Rise time : < 5 ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/76
CMC ID :
EURAMET-TF-FR-00000FH8-1
Time scale difference ,
Time scale difference
:
-1 s to 1 s
Remote clock vs UTC(OP)
Absolute expanded uncertainty
:
2.0E1 ns
GPS single frequency common view
Averaging time : 1 d
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/2
CMC ID :
EURAMET-TF-FR-00000FH5-3
Frequency ,
Frequency
:
-1.00E-10 Hz/Hz to 1.00E-10 Hz/Hz
Local frequency standard
Relative expanded uncertainty
:
1.0E-14 Hz/Hz
1 pps comparison to UTC(OP) using a Time interval counter
Pulse amplitude : > 1 V on 50 ohm
Rise time : < 5 ns
Averaging time : 1 d
Direct comparison between 1 pps signal issued from the frequency standard and UTC(OP)
Approved on 03 July 2019
Institute service identifier : LNE-SYRTE/78
CMC ID :
EURAMET-TF-FR-00000FHF-1