France, LNE-IRSN (Institut de Radioprotection et de Sûreté Nucléaire)
Ionizing radiation
Fluence rate
,
Neutron sensitive device
: 222 (cm2s)-1
Relative expanded uncertainty 5.6 %
Irradiation with calibrated neutron sources
Cf-252 source, bare Cf-252 ISO 8529-1
Reference standard : Manganese sulphate bath
Source of traceability : LNE
Service provided by the LNE-IRSN
Approved on 09 May 2005
Institute service identifier : EUR-RAD-LNE-3001
CMC ID :
EURAMET-RI-FR-00000KYV-1
Ionizing radiation
Fluence rate
,
Neutron sensitive device
: 193 (cm2s)-1
Relative expanded uncertainty 5.5 %
Irradiation with calibrated neutron sources
Cf-252 source, D2O moderated, D2O-mod. Cf-252 ISO 8529-1
Reference standard : Manganese sulphate bath
Source of traceability : LNE
Service provided by the LNE-IRSN
Approved on 09 May 2005
Institute service identifier : EUR-RAD-LNE-3002
CMC ID :
EURAMET-RI-FR-00000KYW-1
Ionizing radiation
Fluence rate
,
Neutron sensitive device
: 286 (cm2s)-1
Relative expanded uncertainty 5.3 %
Irradiation with calibrated neutron sources
Am-241/Be-9 source, Am-241/Be-9 ISO 8529-1
Reference standard : Manganese sulphate bath
Source of traceability : LNE
Service provided by the LNE-IRSN
Approved on 09 May 2005
Institute service identifier : EUR-RAD-LNE-3003
CMC ID :
EURAMET-RI-FR-00000KYX-1