Results for: FORCE Technology
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Chinese Taipei, CMS (became CMS/ITRI) (ITRI Center for Measurement Standards (became Industrial Technology Research Institute/Center for Measurement Standards))
Force ,
Force: compression
:
50 kN to 500 kN
Force measuring device
Relative expanded uncertainty
:
3.0E-4
Direct comparison
Approved on 16 January 2015
Institute service identifier : CMS/N04
CMC ID :
APMP-M-TW-00000G7Z-1
Force ,
Force: compression, tension
:
5 kN to 50 kN
Force measuring device
Relative expanded uncertainty
:
3.0E-5
Direct comparison
Approved on 16 January 2015
Institute service identifier : CMS/N01
CMC ID :
APMP-M-TW-00000G7Y-1
Hardness ,
Hardness
:
40 HR to 100 HR
Hardness Block
Absolute expanded uncertainty
:
0.4 HR
Rockwell B (with ball indenter) according to ISO 6508:3
Preliminary test force : 98.07 N
Total test force : 980.7 N
Approved on 16 January 2015
Institute service identifier : CMS/N06
CMC ID :
APMP-M-TW-00000G75-1
Force ,
Force: compression, tension
:
500 N to 5000 N
Force measuring device
Relative expanded uncertainty
:
2.0E-5
Direct comparison
Approved on 16 January 2015
Institute service identifier : CMS/N02
CMC ID :
APMP-M-TW-00000G7X-1
Hardness ,
Hardness
:
60 HR to 90 HR
Hardness Block
Absolute expanded uncertainty
:
0.3 HR
Rockwell A (with diamond indenter) according to ISO 6508:3
Preliminary test force : 98.07 N
Total test force : 588.40 N
Approved on 16 January 2015
Institute service identifier : CMS/N06
CMC ID :
APMP-M-TW-00000G74-1
Hardness ,
Hardness
:
20 HR to 65 HR
Hardness Block
Absolute expanded uncertainty
:
0.3 HR
Rockwell C (with diamond indenter) according to ISO 6508:3
Preliminary test force : 98.07 N
Total test force : 1471 N
Approved on 16 January 2015
Institute service identifier : CMS/N06
CMC ID :
APMP-M-TW-00000G76-1
Force ,
Force: compression
:
500 kN to 2000 kN
Force measuring device
Relative expanded uncertainty
:
5.0E-4
Direct comparison
Approved on 16 January 2015
Institute service identifier : CMS/N03
CMC ID :
APMP-M-TW-00000G80-1
Denmark, FORCE (FORCE Technology)
Pressure ,
Negative gauge pressure
:
-1000 Pa to 0 Pa
Pressure gauge
Absolute expanded uncertainty
:
0.3 Pa
Gas medium
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009IY-1
Pressure ,
Gauge pressure
:
1.00E5 Pa to 8.00E7 Pa
Pressure balance
Absolute expanded uncertainty
36 + 1E-04p p pressure in Pa
The uncertainty is expressed in Pa
Oil medium
Uncertainty values range from 4.6E+01 Pa to 8.0E+03 Pa
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009J4-1
Pressure ,
Gauge pressure
:
1.00E4 Pa to 2.00E7 Pa
Pressure balance
Absolute expanded uncertainty
3 + 1E-04p p pressure in Pa
The uncertainty is expressed in Pa
Gas medium
Uncertainty values range from 4.0 Pa to 2.0E+03 Pa
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009J2-1
Hygrometers ,
Dew-point temperature
:
-55 °C to 20 °C
Dew-point hygrometer
Absolute expanded uncertainty
:
0.25 °C to 0.23 °C
Split flow comparison
Ambient temperature : 21 °C to 25 ºC
Approved on 03 November 2009
CMC ID :
EURAMET-T-DK-00000CQ0-1
Force ,
Force: compression, tension
:
1 kN to 100 kN
Force measuring device
Relative expanded uncertainty
:
1.0E-2 % to 3.0E-2 %
Jockey Weight
Approved on 16 September 2021
CMC ID :
EURAMET-M-DK-00000JQJ-1
Fluid flow ,
Volume gas flowrate
:
2 m3/h to 400 m3/h
Flow meters, volume meters
Relative expanded uncertainty
:
8.0E-2 % to 0.15 %
Pulses, analog or mA signals
Fluid : high pressure natural gas/bio natural gas and air
Temperature : 15 °C to 25°C
Pressure : 0 MPa gauge to 6.5 MPa gauge
Pipe size: Various tubing
Approved on 11 September 2019
Institute service identifier : DK42
CMC ID :
EURAMET-M-DK-00000K10-1
Fluid flow ,
Volume gas flowrate
:
5.00E-3 m3/h to 10 m3/h
Flow meters, volume meters
Relative expanded uncertainty
:
0.1 %
Pulses, analog or mA signals
Fluid : air
Temperature : 20 °C ± 1 °C
Pipe size: Various tubing
Approved on 11 September 2019
Institute service identifier : DK1
CMC ID :
EURAMET-M-DK-000009K5-2
Fluid flow ,
Volume of liquid
:
5 L to 100 L
Flow meter
Relative expanded uncertainty
:
9.0E-2 % to 0.25 %
Mechanical, on-site
Liquid : gas-oils or similar
Reference Temperature : air 15 °C to 28 °C liquid, 10 °C to 33 °C
Approved on 11 September 2019
Institute service identifier : DK16
CMC ID :
EURAMET-M-DK-000009JH-2
Fluid flow ,
Volume of liquid
:
80 mL to 5000 mL
Laboratory/ Proving equipment
Relative expanded uncertainty
:
6.0E-3 % to 1.3E-2 %
e.g. burettes, pycnometers, disp.
Liquid : water
Temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : DK20
CMC ID :
EURAMET-M-DK-000009II-2
Force ,
Force: compression, tension
:
0.1 N to 1000 N
Force measuring device
Relative expanded uncertainty
:
1.0E-2 %
Deadweight
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009K3-1
Pressure ,
Absolute pressure
:
1500 Pa to 1.50E4 Pa
Pressure gauge
Absolute expanded uncertainty
:
6 Pa
Gas medium
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009IV-1
Pressure ,
Absolute pressure
:
1.50E4 Pa to 1.50E5 Pa
Barometer
Absolute expanded uncertainty
:
9 Pa
Gas medium
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009IW-1
Pressure ,
Gauge pressure
:
0 Pa to 1000 Pa
Pressure gauge
Absolute expanded uncertainty
:
0.3 Pa
Gas medium
Approved on 11 October 2005
CMC ID :
EURAMET-M-DK-000009IZ-1