CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Denmark, HBK-DPLA (Hottinger Brüel & Kjaer A/S - Danish Primary Laboratory for Acoustics Section)
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 16.1 kHz to 20.0 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PM-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 8.1 kHz to 10 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PF-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 25 Hz to 49 Hz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PH-1
 
Linear vibration , Voltage sensitivity (modulus)
Acceleration measuring chain
Relative expanded uncertainty : 0.5 %
ISO 16063-11
Frequency : 0.1 Hz to <0.2 Hz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009Q0-1
 
Linear vibration , Voltage sensitivity (modulus)
Acceleration measuring chain
Relative expanded uncertainty : 0.4 %
ISO 16063-11
Frequency : 0.2 Hz to 5 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009Q1-1
 
Linear vibration , Charge sensitivity (modulus)
Accelerometer
Relative expanded uncertainty : 0.5 %
ISO 16063-11
Frequency : 0.1 Hz to <0.2 Hz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009Q3-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 0.14 dB
IEC 61094-2:1992
Frequency : 20.1 kHz to 25.2 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PN-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 5.0E-2 dB
IEC 61094-2:1992
Frequency : 25 Hz to 49 Hz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PA-1
 
Linear vibration , Charge sensitivity (phase shift) : -180 ° to 180 °
Accelerometer
Absolute expanded uncertainty : 0.4 °
ISO 16063-11
Frequency : 0.1 Hz to <0.2 Hz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009P6-1
 
Linear vibration , Charge sensitivity (phase shift) : -180 ° to 180 °
Accelerometer
Absolute expanded uncertainty : 1 °
ISO 16063-11
Frequency : >5 kHz to 10 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009P8-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 5.0E-2 dB
IEC 61094-2:1992
Frequency : 12.7 kHz to 16.0 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PL-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 6.0E-2 dB
IEC 61094-2:1992
Frequency : 19 Hz to 24 Hz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009P9-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 4.0E-2 dB
IEC 61094-2:1992
Frequency : 50 Hz to 99 Hz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PI-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 3.0E-2 dB
IEC 61094-2:1992
Frequency : 50 Hz to 99 Hz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PB-1
 
Linear vibration , Voltage sensitivity (modulus)
Acceleration measuring chain
Relative expanded uncertainty : 0.6 %
ISO 16063-11
Frequency : >5 kHz to 10 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009Q2-1
 
Linear vibration , Charge sensitivity (modulus)
Accelerometer
Relative expanded uncertainty : 0.6 %
ISO 16063-11
Frequency : >5 kHz to 10 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009Q5-1
 
Linear vibration , Voltage sensitivity (phase shift) : -180 ° to 180 °
Acceleration measuring chain
Absolute expanded uncertainty : 0.3 °
ISO 16063-11
Frequency : 0.1 Hz to 5 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009P4-1
 
Linear vibration , Charge sensitivity (phase shift) : -180 ° to 180 °
Accelerometer
Absolute expanded uncertainty : 0.3 °
ISO 16063-11
Frequency : 0.2 Hz to 5 kHz
Approved on 17 January 2018
CMC ID : EURAMET-AUV-DK-000009P7-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2
Absolute expanded uncertainty : 4.0E-2 dB
IEC 61094-2:1992
Frequency : 10.1 kHz to 12.6 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PK-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1
Absolute expanded uncertainty : 5.0E-2 dB
IEC 61094-2:1992
Frequency : 4.1 kHz to 8.0 kHz
Approved on 27 December 2007
CMC ID : EURAMET-AUV-DK-000009PE-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.