Results for: D.I. Mendeleyev Institute for Metrology, Rosstandart
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
1348 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Chemical material
Chemical Analyte
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Russian Federation, VNIIM (D.I. Mendeleyev Institute for Metrology, Rosstandart)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solution 15 to 25 0.1 15 to 25 0.1
  • Mechanism for measurement service delivery : SM 07.06.05 plus calibration
  • Temperature range is from 10 °C to 30 °C. Data is given for 25 °C
  • Approved on 19 June 2014
  • Institute service identifier : 7-04
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
seawater 10 to 15 5.0E-2 10 to 15 0.1
  • Mechanism for measurement service delivery : CRM, calibration
  • Temperature range from 15°C to 25°C
  • Approved on 30 June 2016
  • Institute service identifier : 7-05
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solution 10 to 15 0.1 10 to 15 0.1
  • Mechanism for measurement service delivery : SM 07.06.05 plus calibration
  • Temperature range is from 0 °C to 90 °C. Data is given for 25 °C
  • Approved on 06 December 2011
  • Institute service identifier : 7-03
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1,1,1-trichloroethane 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/17 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-56a
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
synthetic air 1,1,1-trichloroethane 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/18 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-56b
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
synthetic air 1,1,2-trichloroethane 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/30 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-62b
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1,1,2-trichloroethane 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/29 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-62a
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
synthetic air 1,1-dichloroethylene 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/26 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-60b
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1,1-dichloroethylene 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030/25 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-60a
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1,2-dichloroethane 0.05 to 100 4 to 3 0.05 to 100 6 to 4
  • Mechanism for measurement service delivery : PRM SM 06.02.030/9 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-52a
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1,2-dichloroethane 0.05 to 100 4 to 3 0.05 to 100 6 to 4
nitrogen benzene 0.05 to 100 3 to 2 0.05 to 100 5 to 3
nitrogen chloroform 0.05 to 100 3 to 2 0.05 to 100 5 to 3
nitrogen dichloromethane 0.05 to 100 3 to 2 0.05 to 100 5 to 3
nitrogen tetrachloroethylene 0.05 to 100 3 to 2 0.05 to 100 5 to 3
nitrogen trichloroethylene 0.05 to 100 3 to 2 0.05 to 100 5 to 3
nitrogen vinyl chloride 0.05 to 100 3 to 2 0.05 to 100 5 to 3
  • Mechanism for measurement service delivery : PRM SM 06.02.030 plus instrument calibration
  • Approved on 21 October 2001
  • Institute service identifier : 4.2-66
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
synthetic air 1,2-dichloroethane 0.05 to 100 4 to 3 0.05 to 100 6 to 4
  • Mechanism for measurement service delivery : PRM SM 06.02.030/10 plus instrument calibration
  • Approved on 24 January 2006
  • Institute service identifier : 4.2-52b
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mol/mol Relative expanded uncertainty in %
helium 1,3-butadiene 5.00E-3 to 0.03 0.5 5.00E-3 to 0.03 0.5
helium 1-butene 1.00E-3 to 0.01 0.5 1.00E-3 to 0.01 0.5
helium ethane 0.01 to 0.1 0.3 0.01 to 0.1 0.3
helium ethene 0.05 to 0.2 0.3 0.05 to 0.2 0.3
helium helium 0.01 to 0.7 0.3 0.01 to 0.7 0.3
helium hydrogen 0.05 to 0.2 0.6 0.05 to 0.2 0.6
helium isobutylene 1.00E-3 to 0.01 0.6 1.00E-3 to 0.01 0.6
helium methane 0.05 to 0.2 0.3 0.05 to 0.2 0.3
helium nitrogen 0.01 to 0.7 0.5 0.01 to 0.7 0.5
helium propane 1.00E-3 to 0.05 0.5 1.00E-3 to 0.05 0.5
helium propene 5.00E-3 to 0.1 0.4 5.00E-3 to 0.1 0.4
  • Mechanism for measurement service delivery : SM2.706.136-454
  • Approved on 21 October 2001
  • Institute service identifier : 4.3-10
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1-butanol 0.5 to 20 5 to 2 0.5 to 20 5 to 2
  • Mechanism for measurement service delivery : Calibration
  • Approved on 09 December 2004
  • Institute service identifier : 4.2-34a
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
air 1-butanol 0.5 to 20 5 to 2 0.5 to 20 5 to 2
  • Mechanism for measurement service delivery : Calibration
  • Approved on 09 December 2004
  • Institute service identifier : 4.2-34b
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in cmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in cmol/mol Relative expanded uncertainty in %
mixture of liquefied hydrocarbons 1-butene 1 to 5 0.5 1 to 5 0.5
mixture of liquefied hydrocarbons ethane 1 to 5 1.4 1 to 5 1.4
mixture of liquefied hydrocarbons isobutane 2 to 10 0.4 2 to 10 0.4
mixture of liquefied hydrocarbons isopentane 0.5 to 2 3.3 0.5 to 2 3.3
mixture of liquefied hydrocarbons n-butane 5 to 90 0.5 5 to 90 0.5
mixture of liquefied hydrocarbons propane 5 to 90 0.5 5 to 90 0.5
mixture of liquefied hydrocarbons propene 5 to 15 0.5 5 to 15 0.5
  • Mechanism for measurement service delivery : PRM plus calibration
  • Approved on 21 October 2001
  • Institute service identifier : 4.3-22
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1-propanethiol 0.5 to 5 5 to 2.5 0.5 to 5 5 to 2.5
  • Mechanism for measurement service delivery : PRM plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 30 June 2016
  • Institute service identifier : 4.6-67
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen 1-propanethiol 5 to 100 2.5 to 2 5 to 100 2.5 to 2
  • Mechanism for measurement service delivery : PRM plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 30 June 2016
  • Institute service identifier : 4.6-78
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
methane 1-propanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane 2-butanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane 2-methyl-2-propanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane 2-propanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane butanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane carbon disulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane carbonyl sulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane diethyl disulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane diethyl sulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane dimethyl disulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane dimethyl sulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane ethanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane ethyl methyl sulfide 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane hydrogen sulfide 10 to 500 1.5 to 1 10 to 500 2 to 1.5
methane methanethiol 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
methane tetrahydrothiophene 10 to 1000 1.5 to 1 10 to 1000 2 to 1.5
  • Mechanism for measurement service delivery : SM 06.02.103 plus calibration
  • Approved on 21 October 2001
  • Institute service identifier : 4.3-09
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
methane 1-propanethiol 0.5 to 5 5 to 2.5 0.5 to 5 5 to 2.5
  • Mechanism for measurement service delivery : PRM plus calibration
  • Calibration service involves calibration of gas mixtures of known composition against primary standards on regular basis
  • Approved on 30 June 2016
  • Institute service identifier : 4.3-19

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.