Results for: Costa Rica
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
75 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Costa Rica, LAMETRO-ICE (Laboratorio de Metrologia, Instituto Costarricense de Electricidad)
Fibre optics , Responsivity
Fibre optic power meter
Relative expanded uncertainty : 1.1 %
Laser source and reference fibre optic power meter
IEC 61315
Temperature : (23 ± 2) ºC
Humidity : (40 ± 10) %
Wavelength : 1310 nm and 1550 nm
Optical power level : 100 μW (-10 dBm)
Bandwidth : < 5 nm
Approved on 01 October 2022
Institute service identifier : LM-I-008
Fibre optics , Vacuum wavelength : 1510 nm to 1540 nm
Optical spectrum analyzer
Absolute expanded uncertainty : 6.0E-3 nm
Absortion cell
IEC 62129-1
Temperature : (23 ± 2) °C
Humidity : (40 ± 10) %
Approved on 01 October 2022
Institute service identifier : LM-I-011
Fibre optics , Vacuum wavelength : 1250 nm to 1650 nm
Fibre optic source
Absolute expanded uncertainty : 3.9E-2 nm to 6.7E-2 nm
U = 4.24870E-10 * W^3 - 1.47601E-6 * W^2 + 1.53173E-3 * W - 0.37101 W: Wavelength to be measured in [nm]; U: Expanded uncertainty (k=2) in [nm]
Optical spectrum analyzer
IEC 62129-1
Temperature : (23 ± 2) °C
Humidity : (40 ± 10) %
Approved on 01 October 2022
Institute service identifier : LM-I-010
Fibre optics , Optical Length (distance scale deviation) : 7.5 km to 100 km
OTDR
Relative expanded uncertainty : 2.4E-5 m/m to 3.4E-5 m/m
{"row_1":{"col_1":"Nominal Walelength (nm)","col_2":"Expanded Uncertainty (m/m) (k=2)"},"row_2":{"col_1":"1310","col_2":"2.4E-5"},"row_3":{"col_1":"1550","col_2":"3.4E-5"}}
Recirculating delay line
IEC 61746-1
Temperature : (23 ± 2) °C
Humidity : (40 ± 10) %
Nominal wavelength : 1310 nm and 1550 nm
Approved on 01 October 2022
Institute service identifier : LM-I-016
Fibre optics , Optical Length (distance scale offset) : 7.5 km to 100 km
OTDR
Absolute expanded uncertainty : 5.0E-2 m to 1.3 m
{"row_1":{"col_1":"Nominal Walelength (nm)","col_2":"Expanded Uncertainty (m) (k=2)"},"row_2":{"col_1":"1310","col_2":"0.050"},"row_3":{"col_1":"1550","col_2":"1.3"}}
Recirculating delay line
IEC 61746-1
Temperature : (23 ± 2) °C
Humidity : (40 ± 10) %
Nominal wavelength : 1310 nm and 1550 nm
Approved on 01 October 2022
Institute service identifier : LM-I-016
[com.bipm.kcdb.model.entity.Nmi@21d53835, com.bipm.kcdb.model.entity.Nmi@2232701, com.bipm.kcdb.model.entity.Nmi@480efc04, com.bipm.kcdb.model.entity.Nmi@26fe59d5, com.bipm.kcdb.model.entity.Nmi@70b2c70e, com.bipm.kcdb.model.entity.Nmi@4c40c4ed, com.bipm.kcdb.model.entity.Nmi@2e62d8bc], ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
AC voltage (up to the MHz range) , AC voltage (up to the MHz range): AC voltage up to 1100 V, meters : 0.01 V to 1000 V
AC voltmeter, multimeter, multifunction calibrator
Relative expanded uncertainty : 5.0E1 µV/V to 1.1E4 µV/V
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"10 kHz","col_7":"20 kHz","col_8":"50 kHz","col_9":"100 kHz","col_10":"300 kHz","col_11":"500 kHz","col_12":"1 MHz"},"row_2":{"col_1":"10 mV","col_2":"640","col_3":"480","col_4":"480","col_5":"480","col_6":"480","col_7":"480","col_8":"600","col_9":"1000","col_10":"2050","col_11":"3400","col_12":"4700"},"row_3":{"col_1":"30 mV","col_2":"640","col_3":"313","col_4":"313","col_5":"313","col_6":"313","col_7":"313","col_8":"433","col_9":"1027","col_10":"1567","col_11":"2233","col_12":"4200"},"row_4":{"col_1":"100 mV","col_2":"360","col_3":"150","col_4":"150","col_5":"150","col_6":"150","col_7":"150","col_8":"270","col_9":"630","col_10":"1100","col_11":"1650","col_12":"3150"},"row_5":{"col_1":"300 mV","col_2":"373","col_3":"72","col_4":"72","col_5":"72","col_6":"72","col_7":"72","col_8":"108","col_9":"210","col_10":"687","col_11":"1667","col_12":"2700"},"row_6":{"col_1":"1 V","col_2":"280","col_3":"53","col_4":"53","col_5":"53","col_6":"53","col_7":"53","col_8":"85","col_9":"140","col_10":"500","col_11":"1200","col_12":"2000"},"row_7":{"col_1":"3 V","col_2":"373","col_3":"62","col_4":"62","col_5":"62","col_6":"62","col_7":"62","col_8":"108","col_9":"167","col_10":"475","col_11":"1667","col_12":"2567"},"row_8":{"col_1":"10 V","col_2":"280","col_3":"50","col_4":"50","col_5":"50","col_6":"50","col_7":"50","col_8":"85","col_9":"120","col_10":"335","col_11":"1200","col_12":"1820"},"row_9":{"col_1":"30 V","col_2":"373","col_3":"72","col_4":"72","col_5":"72","col_6":"72","col_7":"72","col_8":"113","col_9":"233","col_10":"1433","col_11":"5733","col_12":"10667"},"row_10":{"col_1":"100 V","col_2":"280","col_3":"58","col_4":"58","col_5":"58","col_6":"58","col_7":"58","col_8":"90","col_9":"175","col_10":"1060","col_11":"4800","col_12":"8800"},"row_11":{"col_1":"300 V","col_2":"–","col_3":"103","col_4":"103","col_5":"103","col_6":"185","col_7":"185","col_8":"–","col_9":"–","col_10":"–","col_11":"–","col_12":"–"},"row_12":{"col_1":"900 V","col_2":"–","col_3":"94","col_4":"94","col_5":"94","col_6":"172","col_7":"172","col_8":"–","col_9":"–","col_10":"–","col_11":"–","col_12":"–"}}
The expanded uncertainties given in this table are expressed in µV/V
Direct comparison
Frequency : 10 Hz to 1 MHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/52201
AC current , AC current up to 100 A: meters : 1.00E-4 A to 11 A
AC ammeter, multimeter, multifunction calibrator
Relative expanded uncertainty : 1.1E2 µA/A to 5.8E3 µA/A
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"5 kHz","col_7":"10 kHz"},"row_2":{"col_1":"220 µA","col_2":"318","col_3":"155","col_4":"155","col_5":"155","col_6":"–","col_7":"1359"},"row_3":{"col_1":"2.2 mA","col_2":"298","col_3":"184","col_4":"184","col_5":"184","col_6":"–","col_7":"2536"},"row_4":{"col_1":"2.2 mA","col_2":"225","col_3":"120","col_4":"120","col_5":"120","col_6":"–","col_7":"1359"},"row_5":{"col_1":"22 mA","col_2":"298","col_3":"184","col_4":"184","col_5":"184","col_6":"–","col_7":"2148"},"row_6":{"col_1":"22 mA","col_2":"225","col_3":"120","col_4":"120","col_5":"120","col_6":"198","col_7":"1242"},"row_7":{"col_1":"220 mA","col_2":"298","col_3":"158","col_4":"158","col_5":"158","col_6":"–","col_7":"1113"},"row_8":{"col_1":"220 mA","col_2":"225","col_3":"113","col_4":"113","col_5":"113","col_6":"–","col_7":"932"},"row_9":{"col_1":"2.2 A","col_2":"–","col_3":"292","col_4":"292","col_5":"292","col_6":"–","col_7":"5849"},"row_10":{"col_1":"2.2 A","col_2":"–","col_3":"229","col_4":"229","col_5":"229","col_6":"411","col_7":"5559"},"row_11":{"col_1":"11 A","col_2":"–","col_3":"401","col_4":"401","col_5":"401","col_6":"–","col_7":"2989"},"row_12":{"col_1":"11 A","col_2":"–","col_3":"370","col_4":"370","col_5":"370","col_6":"–","col_7":"2853"}}
The expanded uncertainties given in this table are expressed in µA/A (uncertainty values depend on range and output)
Direct comparison
Frequency : 10 Hz to 10 kHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/62201
DC current (up to 100 A) , DC current meters: low values : 1.00E-5 A to 11 A
Multimeter
Relative expanded uncertainty : 4.0E1 µA/A to 8.4E2 µA/A
{"row_1":{"col_1":"","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 mA","col_2":"656","col_3":"µA/A"},"row_3":{"col_1":"0.1 mA","col_2":"102","col_3":"µA/A"},"row_4":{"col_1":"&gt; 0.1 mA","col_2":"107","col_3":"µA/A"},"row_5":{"col_1":"1 mA","col_2":"43","col_3":"µA/A"},"row_6":{"col_1":"&gt; 1 mA","col_2":"77","col_3":"µA/A"},"row_7":{"col_1":"10 mA","col_2":"40","col_3":"µA/A"},"row_8":{"col_1":"&gt; 10 mA","col_2":"117","col_3":"µA/A"},"row_9":{"col_1":"100 mA","col_2":"53","col_3":"µA/A"},"row_10":{"col_1":"&gt; 100 mA","col_2":"204","col_3":"µA/A"},"row_11":{"col_1":"1 A","col_2":"94","col_3":"µA/A"},"row_12":{"col_1":"&gt;1 A","col_2":"840","col_3":"µA/A"},"row_13":{"col_1":"11 A","col_2":"404","col_3":"µA/A"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/32101
Impedance (up to the MHz range) , Inductance: self inductance, low values : 10 mH to 100 mH
Fixed inductor
Relative expanded uncertainty : 5.0E1 µH/H
{"row_1":{"col_1":"","col_2":"Parameter","col_3":"Specifications","col_4":"Expanded uncertainty","col_5":"Units"},"row_2":{"col_1":"10 mH","col_2":"Frequency Current","col_3":"1 kHz 7.7 mA","col_4":"50","col_5":"µH/H"},"row_3":{"col_1":"100 mH","col_2":"Frequency Current","col_3":"1 kHz 1.5 mA","col_4":"50","col_5":"µH/H"}}
Substitution using an LCR meter
Frequency : 1 kHz
Current : 1.5 mA to 7.7 mA
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/43201
AC power , AC power and energy: single phase (frequency <= 400 Hz) : 15 W to 1.20E4 W
Watt-hour meter, wattmeter
Relative expanded uncertainty : 2.9E2 µW (VA)-1
Comparison
Frequency : 60 Hz
Applied voltage : 120 V and 240 V
Current : (0.25 A at 120 V and 0.3 A at 240 V) to 50 A
Power factor : 1, 0.5 lead, 0.5 lag
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/71101
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 1.00E-3 V to 0.01 V
DC voltmeter, multimeter
Relative expanded uncertainty : 3.8 µV/V to 4.2E2 µV/V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"&gt; 0.001 V DC","col_2":"416","col_3":"µV/V"},"row_3":{"col_1":"0.01 V DC","col_2":"48","col_3":"µV/V"},"row_4":{"col_1":"&gt; 0.01 V DC","col_2":"48","col_3":"µV/V"},"row_5":{"col_1":"0.1 V DC","col_2":"12","col_3":"µV/V"},"row_6":{"col_1":"&gt; 0.1 V DC","col_2":"12","col_3":"µV/V"},"row_7":{"col_1":"1 V DC","col_2":"5.8","col_3":"µV/V"},"row_8":{"col_1":"&gt; 1 V DC","col_2":"5.8","col_3":"µV/V"},"row_9":{"col_1":"10 V DC","col_2":"3.8","col_3":"µV/V"},"row_10":{"col_1":"&gt; 10 V DC","col_2":"3.8","col_3":"µV/V"},"row_11":{"col_1":"100 V DC","col_2":"5.5","col_3":"µV/V"},"row_12":{"col_1":"&gt;100 V DC","col_2":"5.5","col_3":"µV/V"},"row_13":{"col_1":"1000 V DC","col_2":"7","col_3":"µV/V"}}
Direct comparison
Measurement lower limit for values > 0.001 V
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/12201
DC resistance , DC resistance standards and sources: low values : 0.1 Ω to 1.00E8 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 1.0E1 µΩ/Ω to 4.7E2 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"0.1 Ω","col_2":"402","col_3":"µΩ/Ω"},"row_3":{"col_1":"1 Ω","col_2":"53","col_3":"µΩ/Ω"},"row_4":{"col_1":"&gt; 1 Ω","col_2":"53","col_3":"µΩ/Ω"},"row_5":{"col_1":"10 Ω","col_2":"18","col_3":"µΩ/Ω"},"row_6":{"col_1":"&gt; 10 Ω","col_2":"50","col_3":"µΩ/Ω"},"row_7":{"col_1":"100 Ω","col_2":"16","col_3":"µΩ/Ω"},"row_8":{"col_1":"&gt; 100 Ω","col_2":"14","col_3":"µΩ/Ω"},"row_9":{"col_1":"1 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_10":{"col_1":"&gt; 1 kΩ","col_2":"14","col_3":"µΩ/Ω"},"row_11":{"col_1":"10 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_12":{"col_1":"&gt; 10 kΩ","col_2":"14","col_3":"µΩ/Ω"},"row_13":{"col_1":"100 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_14":{"col_1":"&gt; 100 kΩ","col_2":"30","col_3":"µΩ/Ω"},"row_15":{"col_1":"1 MΩ","col_2":"16","col_3":"µΩ/Ω"},"row_16":{"col_1":"&gt; 1 MΩ","col_2":"119","col_3":"µΩ/Ω"},"row_17":{"col_1":"10 MΩ","col_2":"49","col_3":"µΩ/Ω"},"row_18":{"col_1":"&gt; 10 MΩ","col_2":"468","col_3":"µΩ/Ω"},"row_19":{"col_1":"100 MΩ","col_2":"398","col_3":"µΩ/Ω"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/21101
DC current (up to 100 A) , DC current sources: low values : 1.00E-5 A to 10 A
Multifunction calibrator, current generator
Relative expanded uncertainty : 2.3E1 µA/A to 4.2E2 µA/A
{"row_1":{"col_1":"","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 mA","col_2":"82","col_3":"µA/A"},"row_3":{"col_1":"0.1 mA","col_2":"26","col_3":"µA/A"},"row_4":{"col_1":"&gt; 0.1 mA","col_2":"59","col_3":"µA/A"},"row_5":{"col_1":"1 mA","col_2":"23","col_3":"µA/A"},"row_6":{"col_1":"&gt; 1 mA","col_2":"59","col_3":"µA/A"},"row_7":{"col_1":"10 mA","col_2":"23","col_3":"µA/A"},"row_8":{"col_1":"&gt; 10 mA","col_2":"70","col_3":"µA/A"},"row_9":{"col_1":"100 mA","col_2":"35","col_3":"µA/A"},"row_10":{"col_1":"&gt; 100 mA","col_2":"167","col_3":"µA/A"},"row_11":{"col_1":"1 A","col_2":"97","col_3":"µA/A"},"row_12":{"col_1":"&gt;1 A","col_2":"235","col_3":"µA/A"},"row_13":{"col_1":"10 A","col_2":"418","col_3":"µA/A"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/31101
DC voltage (up to 1100 V) , DC voltage sources: low value ranges : 0.01 V to 1000 V
DC voltage source, multifunction calibrator
Relative expanded uncertainty : 4.9 µV/V to 1.6E2 µV/V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 V DC","col_2":"161","col_3":"µV/V"},"row_3":{"col_1":"0.1 V DC","col_2":"21","col_3":"µV/V"},"row_4":{"col_1":"&gt; 0.1 V DC","col_2":"21","col_3":"µV/V"},"row_5":{"col_1":"1 V DC","col_2":"6.2","col_3":"µV/V"},"row_6":{"col_1":"&gt; 1 V DC","col_2":"6.2","col_3":"µV/V"},"row_7":{"col_1":"10 V DC","col_2":"4.9","col_3":"µV/V"},"row_8":{"col_1":"&gt; 10 V DC","col_2":"4.9","col_3":"µV/V"},"row_9":{"col_1":"100 V DC","col_2":"6.4","col_3":"µV/V"},"row_10":{"col_1":"&gt;100 V DC","col_2":"6.4","col_3":"µV/V"},"row_11":{"col_1":"1000 V DC","col_2":"15.6","col_3":"µV/V"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/11201
Impedance (up to the MHz range) , Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors : 10 pF to 1000 pF
Fixed capacitor, capacitance box
Relative expanded uncertainty : 5.0E1 µF/F
{"row_1":{"col_1":"","col_2":"Parameter","col_3":"Specifications","col_4":"Expanded uncertainty","col_5":"Units"},"row_2":{"col_1":"10 pF","col_2":"Frequency Voltage","col_3":"1 kHz 15 V","col_4":"50","col_5":"µF/F"},"row_3":{"col_1":"100 pF","col_2":"Frequency Voltage","col_3":"1 kHz 15 V","col_4":"50","col_5":"µF/F"},"row_4":{"col_1":"1000 pF","col_2":"Frequency Voltage","col_3":"1 kHz 1.5 V","col_4":"50","col_5":"µF/F"}}
Substitution
Frequency : 1 kHz
Voltage : 1.5 to 15 V
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/42201
AC voltage (up to the MHz range) , AC voltage (up to the MHz range): AC voltage up to 1100 V, sources : 0.01 V to 1000 V
Multifunction calibrator, source, oscilloscope calibrator
Relative expanded uncertainty : 7.2E1 µV/V to 3.1E4 µV/V
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"10 kHz","col_7":"20 kHz","col_8":"50 kHz","col_9":"100 kHz","col_10":"300 kHz","col_11":"500 kHz"},"row_2":{"col_1":"10 mV","col_2":"467","col_3":"242","col_4":"242","col_5":"242","col_6":"320","col_7":"320","col_8":"863","col_9":"3969","col_10":"31213","col_11":"–"},"row_3":{"col_1":"30 mV","col_2":"159","col_3":"108","col_4":"108","col_5":"108","col_6":"162","col_7":"162","col_8":"286","col_9":"674","col_10":"2590","col_11":"8024"},"row_4":{"col_1":"100 mV","col_2":"87","col_3":"72","col_4":"72","col_5":"72","col_6":"126","col_7":"126","col_8":"250","col_9":"638","col_10":"2408","col_11":"7843"},"row_5":{"col_1":"300 mV","col_2":"159","col_3":"108","col_4":"108","col_5":"108","col_6":"162","col_7":"162","col_8":"286","col_9":"674","col_10":"2590","col_11":"8024"},"row_6":{"col_1":"1 V","col_2":"87","col_3":"72","col_4":"72","col_5":"72","col_6":"126","col_7":"126","col_8":"250","col_9":"638","col_10":"2408","col_11":"7843"},"row_7":{"col_1":"3 V","col_2":"159","col_3":"108","col_4":"108","col_5":"108","col_6":"162","col_7":"162","col_8":"286","col_9":"674","col_10":"2590","col_11":"8024"},"row_8":{"col_1":"10 V","col_2":"87","col_3":"72","col_4":"72","col_5":"72","col_6":"126","col_7":"126","col_8":"250","col_9":"638","col_10":"2408","col_11":"7843"},"row_9":{"col_1":"30 V","col_2":"260","col_3":"209","col_4":"209","col_5":"209","col_6":"209","col_7":"209","col_8":"325","col_9":"985","col_10":"3366","col_11":"11906"},"row_10":{"col_1":"100 V","col_2":"188","col_3":"172","col_4":"172","col_5":"172","col_6":"172","col_7":"172","col_8":"289","col_9":"949","col_10":"3185","col_11":"11725"},"row_11":{"col_1":"300 V","col_2":"416","col_3":"364","col_4":"364","col_5":"364","col_6":"519","col_7":"519","col_8":"985","col_9":"2383","col_10":"–","col_11":"–"},"row_12":{"col_1":"1000 V","col_2":"343","col_3":"328","col_4":"328","col_5":"328","col_6":"483","col_7":"483","col_8":"949","col_9":"2346","col_10":"–","col_11":"–"}}
The expanded uncertainties given in this table are expressed in µV/V
Direct comparison
Frequency : 10 Hz to 500 kHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/52101
AC current , AC current up to 100 A: sources : 1.00E-4 A to 10 A
Multifunction calibrator, source
Relative expanded uncertainty : 3.9E2 µA/A to 8.8E3 µA/A
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"10 kHz","col_7":"20 kHz","col_8":"50 kHz","col_9":"100 kHz"},"row_2":{"col_1":"100 µA","col_2":"3342","col_3":"1401","col_4":"703","col_5":"703","col_6":"–","col_7":"–","col_8":"–","col_9":"–"},"row_3":{"col_1":"1 mA","col_2":"3627","col_3":"1686","col_4":"987","col_5":"754","col_6":"987","col_7":"987","col_8":"4145","col_9":"8156"},"row_4":{"col_1":"1 mA","col_2":"3265","col_3":"1324","col_4":"625","col_5":"392","col_6":"625","col_7":"625","col_8":"3420","col_9":"5439"},"row_5":{"col_1":"10 mA","col_2":"3627","col_3":"1686","col_4":"987","col_5":"754","col_6":"987","col_7":"987","col_8":"4145","col_9":"8156"},"row_6":{"col_1":"10 mA","col_2":"3265","col_3":"1324","col_4":"625","col_5":"392","col_6":"625","col_7":"625","col_8":"3420","col_9":"5439"},"row_7":{"col_1":"100 mA","col_2":"3627","col_3":"1686","col_4":"987","col_5":"754","col_6":"987","col_7":"987","col_8":"4145","col_9":"8156"},"row_8":{"col_1":"100 mA","col_2":"3265","col_3":"1324","col_4":"625","col_5":"392","col_6":"625","col_7":"625","col_8":"3420","col_9":"5439"},"row_9":{"col_1":"1 A","col_2":"3627","col_3":"1764","col_4":"1143","col_5":"1298","col_6":"2851","col_7":"2851","col_8":"8803","col_9":"–"},"row_10":{"col_1":"1 A","col_2":"3265","col_3":"1401","col_4":"780","col_5":"936","col_6":"2488","col_7":"2488","col_8":"8078","col_9":"–"},"row_11":{"col_1":"10 A","col_2":"–","col_3":"–","col_4":"530","col_5":"–","col_6":"–","col_7":"–","col_8":"–","col_9":"–"},"row_12":{"col_1":"10 A","col_2":"–","col_3":"–","col_4":"490","col_5":"–","col_6":"–","col_7":"–","col_8":"–","col_9":"–"}}
The expanded uncertainties given in this table are expressed in µA/A (uncertainty values depend on range and reading)
Direct comparison
Frequency : 10 Hz to 100 kHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/62101
DC resistance , DC resistance meters: intermediate values : 1.9 Ω to 1.00E8 Ω
Multimeter
Relative expanded uncertainty : 8.7 µΩ/Ω to 1.0E2 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty"},"row_2":{"col_1":"1.9 Ω","col_2":"97"},"row_3":{"col_1":"10 Ω","col_2":"23"},"row_4":{"col_1":"19 Ω","col_2":"23"},"row_5":{"col_1":"100 Ω","col_2":"10"},"row_6":{"col_1":"190 Ω","col_2":"10"},"row_7":{"col_1":"1 kΩ","col_2":"8.7"},"row_8":{"col_1":"1.9 kΩ","col_2":"8.7"},"row_9":{"col_1":"10 kΩ","col_2":"8.7"},"row_10":{"col_1":"19 kΩ","col_2":"8.7"},"row_11":{"col_1":"100 kΩ","col_2":"11"},"row_12":{"col_1":"190 kΩ","col_2":"11"},"row_13":{"col_1":"1 MΩ","col_2":"20"},"row_14":{"col_1":"1.9 MΩ","col_2":"21"},"row_15":{"col_1":"10 MΩ","col_2":"41"},"row_16":{"col_1":"19 MΩ","col_2":"51"},"row_17":{"col_1":"100 MΩ","col_2":"102"}}
Direct comparison
Resistance, fixed values : 1.9 O, 10 O, 19 O, 100 O, 190 O, 1 kO, 1.9 kO, 10 kO, 19 kO, 100 kO, 190 kO, 1 MO, 1.9 MO, 10 MO, 19 MO, 100 MO
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/22201
DC resistance , DC resistance standards and sources: high values : 20 MΩ to 200 MΩ
Fixed resistor, resistance box
Relative expanded uncertainty : 2.5E1 µΩ/Ω to 1.1E3 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Maximum value","col_3":"Units","col_4":"Parameter","col_5":"Specifications","col_6":"Expanded Uncertainty","col_7":"Units"},"row_2":{"col_1":"2","col_2":"20","col_3":"MΩ","col_4":"Temperature Voltage","col_5":"23 °C 1 V to 100 V","col_6":"25","col_7":"µΩ/Ω"},"row_3":{"col_1":"20","col_2":"200","col_3":"MΩ","col_4":"Temperature Voltage","col_5":"23 °C 1 V to 1000 V","col_6":"50","col_7":"µΩ/Ω"},"row_4":{"col_1":"0.2","col_2":"2","col_3":"GΩ","col_4":"Temperature Voltage","col_5":"23 °C 1 V to 1000 V","col_6":"100 to 150","col_7":"µΩ/Ω"},"row_5":{"col_1":"2","col_2":"20","col_3":"GΩ","col_4":"Temperature Voltage","col_5":"23 °C 1 V to 1000 V","col_6":"150 to 1100","col_7":"µΩ/Ω"},"row_6":{"col_1":"20","col_2":"200","col_3":"GΩ","col_4":"Temperature Voltage","col_5":"23 °C 1 V to 1000 V","col_6":"500","col_7":"µΩ/Ω"}}
Direct comparison
Temperature : 23 °C
Voltage : 1000 V
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/21303
[com.bipm.kcdb.model.entity.Nmi@21d53835, com.bipm.kcdb.model.entity.Nmi@2232701, com.bipm.kcdb.model.entity.Nmi@480efc04, com.bipm.kcdb.model.entity.Nmi@26fe59d5, com.bipm.kcdb.model.entity.Nmi@70b2c70e, com.bipm.kcdb.model.entity.Nmi@4c40c4ed, com.bipm.kcdb.model.entity.Nmi@2e62d8bc], LACOMET (Laboratorio Costarricense de Metrologia)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in
natural water, synthetic water, acid solution (up 10 %) potassium 0.14 to 1.00E4 1.1E-2 to 1.5E2
  • Mechanism for measurement service delivery : Assigning values to PT scheme samples, internal calibration
  • Approved on 23 October 2019
  • Institute service identifier : 13.1.0.1.3, 32.1.0.0.1 and 34.1.0.0.1

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.