In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Chinese Taipei, CMS (ITRI Center for Measurement Standards)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 0.5 to 160 1 to 0.2 0.5 to 160 0.5 to 1.6E2
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C003
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon monoxide 1 to 100 1 to 0.5 1 to 100 1 to 1.0E2
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C001
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
air methane 1 to 20 0.8 to 0.3 1 to 20 1 to 2.0E1
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C015
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen methane 0.5 to 1 1 to 0.8 0.5 to 1 0.5 to 1
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C005
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen methane 1 to 500 0.8 to 0.2 1 to 500 1 to 5.0E2
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C006
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mol/mol Relative expanded uncertainty in %
nitrogen oxygen 0.05 to 0.3 1 to 0.1 0.05 to 0.3 5.0E-2 to 0.3
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C014
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen propane 1 to 50 1 to 0.5 1 to 50 1 to 5.0E1
  • Mechanism for measurement service delivery : CMS-CRM/Calibration service
  • Approved on 08 July 2020
  • Institute service identifier : CRM-C007
Linear vibration , Voltage sensitivity (magnitude)
Acceleration measuring chain
Relative expanded uncertainty : 0.5 %
ISO 16063-11 interferometry by fringe-counting method
Acceleration : 5 m/s2 to 100 m/s2
Frequency : 50 Hz to 200 Hz
Approved on 21 October 2001
Institute service identifier : CMS/V-01
Linear vibration , Voltage sensitivity (magnitude)
Acceleration measuring chain
Relative expanded uncertainty : 0.37 %
ISO 16063-11 interferometry by fringe-counting method
Acceleration : 0.5 m/s2 to 5 m/s2
Frequency : 5 Hz to 40 Hz
Approved on 21 October 2001
Institute service identifier : CMS/V-04
Linear vibration , Voltage sensitivity (magnitude)
Acceleration measuring chain
Relative expanded uncertainty : 3.1 %
Comparison, ISO 5347-3
Frequency : 100 Hz
Approved on 21 October 2001
Institute service identifier : CMS/V-02
Items for defining ITS-90 , Temperature : 961.78 °C
Fixed-point blackbody furnace (Ag)
Absolute expanded uncertainty : 0.74 °C
Comparison using radiation thermometer
Wavelength : 0.65 µm

ified on 09 February 2015
Approved on 05 June 2014
Institute service identifier : CMS/T01
Items for defining ITS-90 , Temperature : 231.928 °C
SPRT
Absolute expanded uncertainty : 1.1 mK
Tin freezing point cell
Furnace : 3-zone

Modified on 09 February 2015
Approved on 28 June 2007
Items for defining ITS-90 , Temperature : 660.323 °C
SPRT
Absolute expanded uncertainty : 4.1 mK
Aluminum freezing point cell

ified on 09 February 2015
Approved on 05 June 2014
Institute service identifier : CMS/T05
Items for defining ITS-90 , Temperature : 29.7646 °C
SPRT
Absolute expanded uncertainty : 0.48 mK
Gallium melting point cell

Modified on 09 February 2015
Approved on 28 June 2007
Spectral.-int. meas. for sources and detectors , Chromaticity response
Colorimeter
Absolute expanded uncertainty : 3.0E-3
Spectroradiometer
Correlated colour temperature : 2500 K to 3500 K
Approved on 27 September 2004
Spectral properties of materials , Radiance factor
General material
Relative expanded uncertainty : 0.54 % to 1.2 %
Spectrophotometer
Specific measurement conditions : d/0
Uncertainty of 0.54 for white, 0.85 for red, 1.15 for blue, and 0.56 for green.
Approved on 27 September 2004
Fluid flow , Gas flowrate : 15 m3/h to 1.20E4 m3/h
Gas-flow meter
Relative expanded uncertainty : 0.12 %
Primary method (Weighing tank: 160 kg; flying start / finish)
Fluid : dry air
Absolute pressure : 0.5 MPa to 6 MPa
Temperature : ambient
Mass flow rate: (18 to 14000) kg/h with the same uncertainty. Test line: (25 to 150) mm. Stated volume flow rate is the actural flow rate multiplied by the working pressure.
Approved on 28 December 2017
Institute service identifier : CMS/F05
Fluid flow , Water flowrate : 1 mg/min to 10 mg/min
Liquid Flow meters
Relative expanded uncertainty : 0.7 %
Primary method (Weighing tank: 220 g; flying or standing start / finish, dynamic or static weighing)
Fluid : pure water
Gauge pressure : below 200 kPa
Temperature : 15 °C to 27 °C
Volume flow rate: (1 to 10) mm3/min with relative expanded uncertainties of 0.7 %.
Approved on 28 December 2017
Institute service identifier : CMS/F11
Pressure , Absolute pressure: gas medium : 6.00E-4 Pa to 1 Pa
Vacuum gauge
Relative expanded uncertainty : 2.9E-2
Spinning rotor gauge, comparison method
Temperature : 20 ºC to 25 ºC
Gas species : Nitrogen
Gas purity : 99.9 % or better
Approved on 16 January 2015
Institute service identifier : CMS/L02
Pressure , Gauge pressure: gas medium : 172 kPa to 700 kPa
Pressure measuring device, standard pressure generator
Relative expanded uncertainty : 2.6E-5
Direct comparison with standard, cross float
Approved on 16 January 2015
Institute service identifier : CMS/P04

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.