Austria, E+E (E+E Elektronik)
Hygrometers , Dew-point temperature : -55 °C to -25 °C
Dew-point hygrometer
Absolute expanded uncertainty : 5.0E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 19 March 2012
Institute service identifier : E+E/26
CMC ID : EURAMET-T-AT-00000BL5-1
 
Hygrometers , Relative humidity : 0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
(0.2+t/(-40)*0.1) % + 0.006*h], t (air) temperature in °C

t (air) temperature in °C, h relative humidity in %rh

The uncertainty is expressed in %rh

Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : -40 °C to 0 °C
Approved on 10 November 2015
Institute service identifier : E+E/30
CMC ID : EURAMET-T-AT-00000BLE-1
 
Hygrometers , Relative humidity : 0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
0.1 % + 0.004*h

h relative humidity in %rh

The uncertainty is expressed in %rh

Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : 0 °C to 65 °C
Approved on 10 November 2015
Institute service identifier : E+E/31
CMC ID : EURAMET-T-AT-00000BLF-1
 
Fluid flow , Gas flow speed : 0.3 m/s to 40 m/s
Anemometer, air velocity meter
Relative expanded uncertainty
0.4/vref + 0.47

vref: gas flow speed in m/s

The uncertainty is expressed in %

Comparison with Laser Doppler Anemometer
Gas : air
Atmospheric temperature : 5 °C to 80 °C
Relative humidity : (45 ± 20) % rh
Atmospheric pressure : (1000 ± 80) hPa
Approved on 16 November 2012
Institute service identifier : E+E_AV_1
CMC ID : EURAMET-M-AT-00000FJ0-1
 
Fluid flow , Gas flow speed : 0.04 m/s to 2 m/s
Anemometer, air velocity meter
Relative expanded uncertainty
0.4/vref + 0.47

vref: gas flow speed in m/s

The uncertainty is expressed in %

Comparison with Laser Doppler Anemometer
Gas : air
Ambient temperature : (23 ± 3) °C
Relative humidity : (45 ± 20) % rh
Atmospheric pressure : (1000 ± 80) hPa
Approved on 16 November 2012
Institute service identifier : E+E_AV_2
CMC ID : EURAMET-M-AT-00000FJ1-1
 
Hygrometers , Dew-point temperature : -25 °C to 20 °C
Dew-point hygrometer
Absolute expanded uncertainty : 3.5E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 03 November 2009
Institute service identifier : E+E/27
CMC ID : EURAMET-T-AT-00000BKW-1
 
Hygrometers , Dew-point temperature : 65 °C to 95 °C
Dew-point hygrometer
Absolute expanded uncertainty : 5.0E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 19 March 2012
Institute service identifier : E+E/29
CMC ID : EURAMET-T-AT-00000BL6-1
 
Hygrometers , Dew-point temperature : 20 °C to 65 °C
Dew-point hygrometer
Absolute expanded uncertainty : 3.5E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 03 November 2009
Institute service identifier : E+E/28
CMC ID : EURAMET-T-AT-00000BKX-1
 
Hygrometers , Relative humidity : 0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
0.1 % + 0.004*h

h relative humidity in %rh

The uncertainty is expressed in %rh

Comparison with humidity generator
Continuous gas flow : Maximum 2 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : 65 °C to 95 °C
Approved on 10 November 2015
Institute service identifier : E+E/32
CMC ID : EURAMET-T-AT-00000BLG-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.